SQUARE D

pressure switch XMLC 4 bar - adjustable scale 2 thresholds - 2 C/O

ELECTROMECHANICAL PRESSURE SEN

SQDXMLC004B2S11 T3389110715224
372.79 / EA
http://schema.org/OutOfStock
  • Certifications: CSA, EAC, UL
  • Contact Material: Silver
  • Depth: 90 mm
  • Enclosure Material: Zinc Alloy
  • Height: 158 mm
  • Line Rated Current: 0.1 A, 1.5 A, 120 V, 240 V, 250 V, 3 A
  • Net Weight: 0.685 kg
  • Standard: CE, CSA C22.2 No 14, EN/IEC 60947-5-1, UL 508
  • Storage Temperature: -40-70 °C
  • Warranty Length: 18 mth
  • Width: 55 mm
QTY
  • Specifications
  • Specifications
    • Contacts Type And Composition : 2 C/O
    • Pressure Sensor Type : electromechanical pressure sensor
    • Pressure Actuator : diaphragm
    • Electrical Connection : screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
    • Range Of Product : Telemecanique Pressure sensors XM
    • Line Rated Current : 3 A, B300, AC-15 (Ue = 120 V)EN/IEC 60947-5-1 || 1.5 A, B300, AC-15 (Ue = 240 V)EN/IEC 60947-5-1 || 0.1 A, R300, DC-13 (Ue = 250 V)EN/IEC 60947-5-1
    • Pressure Switch Type Of Operation : regulation between 2 thresholds
    • Cable Entry : cable gland 9-13 mm
    • Product Or Component Type : electromechanical pressure sensor
    • Adjustable Range Of Switching Point On Falling Pressure : 0.15-3.83 bar
    • Materials In Contact With Fluid : FPM, FKM || steel
    • Local Display : with
    • Fluid Connection Type : G 1/4 (female) ISO 228
    • Pressure Sensor Size : 4 bar
    • Controlled Fluid : air 0-160 °C) || fresh water 0-160 °C) || hydraulic oil 0-160 °C)
    • Awg Gauge : AWG 20...AWG 14
    • Scale Type : adjustable differential
    • Electrical Circuit Type : control circuit
    • Enclosure Material : zinc alloy
    • Adjustable Range Of Switching Point On Rising Pressure : 0.3-4 bar
    • Maximum Permissible Accidental Pressure : 9 bar
    • Possible Differential Maximum At High Setting : 2.5 bar
    • Destruction Pressure : 18 bar
    • Device Short Name : XMLC
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Repeat Accuracy : 2 %
    • Height : 158 mm
    • Terminal Block Type : 8 terminals
    • Short-Circuit Protection : 10 A cartridge fuse gG (gl)
    • Contacts Material : silver contacts
    • Possible Differential Minimum At High Setting : 0.17 bar +/- 0.02 bar)
    • Auxiliary Contacts Operation : simultaneous, snap action
    • Net Weight : 0.685 kg
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV EN/IEC 60947-1
    • Maximum Permissible Pressure - Per Cycle : 5 bar
    • Maximum Operating Rate : 120 cyc/mn
    • [Ui] Rated Insulation Voltage : 300 V UL 508 || 500 V EN/IEC 60947-1 || 300 V CSA C22.2 No 14
    • Setting : external
    • Mechanical Durability : 8000000 cycles
    • Width : 55 mm
    • Depth : 90 mm
    • Maximum Resistance Across Terminals : 25 mOhm IEC 255-7 category 3 || 25 mOhm NF C 93-050 method A
    • Possible Differential Minimum At Low Setting : 0.15 bar +/- 0.02 bar)
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110914EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Product Certifications : UL || EAC || CSA
    • Ambient Air Temperature For Operation : -25-70 °C
    • Standards : UL 508 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || CE
    • Vibration Resistance : 4 gn 30-500 Hz)IEC 60068-2-6
    • Shock Resistance : 50 gn IEC 60068-2-27
    • Ip Degree Of Protection : IP66 conforming to EN/IEC 60529
    • Ambient Air Temperature For Storage : -40-70 °C
    • Protective Treatment : TC standard version
    • Operating Position : any position
    • Electrical Shock Protection Class : class I IEC 1140 || class I IEC 536 || class I NF C 20-030