expansion module, Modicon MCM, RS485 safe communication, 1 way, spring

RS485 Safe communications expa

SQDXPSMCMCO0000S1G XPSMCMCO0000S1G 3606480748493
697.95 / EA
http://schema.org/OutOfStock
  • Connection Type: 4 Ways RS485
  • Depth: 114.5 mm
This Modicon MCM safe RS485 bus expansion module for remote extension has 1 single channel transmitter/receiver network connection and is fitted with captive spring clamp terminals. It enables the connection of modular safety controllers type XPSMCMCP0802 and XPSMCMC10804 with the expansion modules placed at distances up to 50m (164ft.) using RS485 shielded cables. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. Combined with safe RS485 bus expansion module type XPSMCMCO0000S2, It allows to create up to 6 decentralized I/O islands. This module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors). This safe bus expansion module is connected to the safety controller via the backplane expansion connector, and uses a RS485 serial interface shielded cable to connect to another safe bus expansion module to create decentralized I/O island. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring up to five decentralized safety related islands with a distance of 50 meters (164.04 ft) between each island on a single Safety controller CPU. Embedding a safe communication between decentralized I/O’s. The safe RS485 bus expansion module Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe RS485 bus expansion module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=XPSMCMCO0000S1G_3D-Simpl, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001233_3D-CAD
  • Communications & Management Attributes
    • Communication Port Protocol : RS485
  • Conformance Attributes
    • Product Certifications : cULus, RCM, TÜV
  • Complementary Attributes
    • Maximum Cable Distance Between Devices : 50 m
    • Us Rated Supply Voltage : 24 V - 20...20 % DC
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Cable Cross Section : 0.2-2.5 mm² - AWG 24...AWG 14 flexible without cable end, 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, with bezel, 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, without bezel, 0.2-2.5 mm² - AWG 24...AWG 14 solid without cable end, 0.5-1 mm² - AWG 20...AWG 18 flexible with cable end, with double bezel
    • Electromagnetic Compatibility : electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2, electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2, susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
    • Local Signalling : LED green PWR power ON, LED green RUN operating, LED red E IN internal error, LED red E EX external error
    • Safety Level : can reach category 4 ISO 13849-1, can reach PL = e ISO 13849-1, can reach SIL 3 IEC 61508, can reach SILCL 3 IEC 62061
    • Vibration Resistance : +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1
    • Carbon Footprint Of The Distribution Phase A4 : 0.0391322836857251, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.5 kg CO2 eq., 0.5102488403826021
    • Carbon Footprint Of The Installation Phase A5 : 0.004006994556426463, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 10 kg CO2 eq., 10.293673359082607
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 112 kg CO2 eq., 111.50379352630267
    • Medium Desc : expansion module, Modicon MCM, RS485 safe communication, 1 way, spring
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-25
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Connector Type : 4 ways RS485
    • Current Consumption : 0.125 mA
    • Device Short Name : XPSMCM
    • Electrical Connection : spring terminal
    • Insulation : 250 V AC between power supply and housing IEC 61800-5-1
    • Mounting Support : omega 35 mm DIN rail EN 50022
    • Overvoltage Category : II
    • Power Dissipation In W : 3 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : safe communication expansion module
    • Quality Labels : CE
    • Range Of Product : Modicon MCM
    • Returnability : No
    • Service Life : 20 year(s)
    • Shock Resistance : 10 gn 16 ms) 1000 shocks on each axis IEC 61496-1
    • Software Version : v6.2.4
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 122 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Connections Terminals : 2 spring clamp terminals, removable terminal block
    • Pep Code : ENVPEP1406025_V3
    • Database Version : 2024-01
    • Pep Verification Date : 2026-01-15
    • Pcr Version : PCR-ed4-FR-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : To monitor with multiple safety means the presence of residual and hazardous voltage and short-circuits between each input and earth and between 32 inputs in an industrial environment at 100% of the time for 10 years.To monitor with multiple safety means the presence of residual and hazardous voltage and short-circuits between each input and earth and between 32 inputs in an industrial environment at 100% of the time for 10 years.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Height Nominal : 99 mm
    • Width Nominal : 22.5 mm
  • Environment Attributes Main
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 122.35085500401003
    • Ambient Air Temperature For Operation : -10-55 °C
    • Ambient Air Temperature For Storage : -20-85 °C
    • Environmental Disclosure : ENVPEP1406025_V3
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Relative Humidity : 10-95 %
    • Pep Code : ENVPEP1406025_V3
    • Pep Verification Date : 2026-01-15
    • Pcr Version : PCR-ed4-FR-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : safe communication expansion module
    • Range Of Product : Modicon MCM
  • ETIM
    • ETIM 8 : EC001423
    • ETIM 9 : EC001423
  • Specifications
    • Depth : 114.5 mm