expansion module, Modicon MCM, 4 safety relay outputs, with diagnostic outout, with backplane connection, spring

4SAFE RELAYEXP8OUT(BACKPLANE C

SQDXPSMCMRO0004DAG XPSMCMRO0004DAG 3606480748868
678.72 / EA
http://schema.org/OutOfStock
  • Depth: 114.5 mm
  • Number of Outputs: 4 Relay
The safe relay output module provides 4 outputs and 8 solid state at 125mA (diagnostics) discrete outputs. It is designed to monitor safety actuators for relay outputs, with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The safe relay modules type XPSMCMER0004 use guided contact safety relays, each of which provides two N.O. contacts and one N.C. contact in addition to the N.C. feedback contact. This safe relay output expansion module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, restart signal, output channels). The safe relay output modules type XPSMCMER0002 and XPSMCMER0004 do not require the backplane expansion connectors as they are directly wired to the selected OSSD. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessory for safe relay output module is a memory card. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=XPSMCMRO0004DAG_3D-Simpl, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001235_3D-CAD
  • Conformance Attributes
    • Product Certifications : TÜV, RCM, cULus
    • Standards : ISO 13849-1, IEC 62061, IEC 61800-5-1, IEC 61508
  • Complementary Attributes
    • Maximum Switching Voltage : 400 V AC, 250 V DC
    • Integrated Connection Type : backplane expansion bus
    • Maximum Power Dissipation In W : 3 W
    • Maximum Switching Current : 6 A
    • Minimum Switching Current : 20 mA
    • Uimp Rated Impulse Withstand Voltage : 4 kV IEC 61800-5-1
    • Us Rated Supply Voltage : 24 V - 20...20 % DC
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Cable Cross Section : 0.2-2.5 mm² - AWG 24...AWG 14 flexible without cable end, 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, with bezel, 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, without bezel, 0.2-2.5 mm² - AWG 24...AWG 14 solid without cable end, 0.5-1 mm² - AWG 20...AWG 18 flexible with cable end, with double bezel
    • Electromagnetic Compatibility : electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2, electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2, susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
    • Local Signalling : 1 LED green PWR power ON, 1 LED green RUN RUN (status), 1 LED red E IN internal error, 1 LED red E EX external error, 2 LEDs orange ADDR node address, 4 LEDs green/red RELAY K1...K4 relay contact, 4 LEDs yellow RST requires reset, 8 LEDs yellow STATUS diagnostics output
    • Safety Level : can reach category 4 ISO 13849-1, can reach PL = e ISO 13849-1, can reach SIL 3 IEC 61508, SILCL 3 IEC 62061
    • Safety Reliability Data : B10d = 300000 AC-15 230 V, , <3 A ISO 13849-1, B10d = 750000 AC-15 230 V, , <1 A ISO 13849-1, B10d = 10000000 DC-13 24 V, , <2 A ISO 13849-1
    • Vibration Resistance : +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1
    • Connections Terminals : 1 spring clamp terminals, removable terminal block, 2 spring clamp terminals, removable terminal block
    • Carbon Footprint Of The Distribution Phase A4 : 0.0430455120542976, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.6 kg CO2 eq., 0.5612737244208622
    • Carbon Footprint Of The Installation Phase A5 : 0.004407694012069108, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 11 kg CO2 eq., 11.323040694990867
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 112 kg CO2 eq., 111.50379352630267
    • Medium Desc : expansion module, Modicon MCM, 4 safety relay outputs, with diagnostic outout, with backplane connection, spring
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-25
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Associated Fuse Rating : 3.5 A, slow-blow
    • Device Short Name : XPSMCM
    • Electrical Connection : spring terminal
    • Electrical Durability : 20000000 cycles
    • Function Of Module : monitoring safety actuators relay output
    • Insulation : 250 V AC between power supply and housing IEC 61800-5-1
    • Mechanical Durability : 20000000 cycles
    • Mounting Support : omega 35 mm DIN rail EN 50022
    • Overvoltage Category : II
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : safe relay output module
    • Quality Labels : CE
    • Range Of Product : Preventa Safety automation
    • Returnability : No
    • Service Life : 20 year(s)
    • Shock Resistance : 10 gn 16 ms 1000 shocks on each axis)IEC 61496-1
    • Software Version : v6.2.4
    • Sustainable Packaging : No
    • Switching Time : 12 ms
    • Switching Voltage : 10 V DC
    • Total Lifecycle Carbon Footprint : 220 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP1406025_V3
    • Database Version : 2024-01
    • Pep Verification Date : 2026-01-15
    • Pcr Version : PCR-ed4-FR-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : To monitor with multiple safety means the presence of residual and hazardous voltage and short-circuits between each input and earth and between 32 inputs in an industrial environment at 100% of the time for 10 years.To monitor with multiple safety means the presence of residual and hazardous voltage and short-circuits between each input and earth and between 32 inputs in an industrial environment at 100% of the time for 10 years.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Height Nominal : 99 mm
    • Width Nominal : 22.5 mm
  • Environment Attributes Main
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 219.9744083033763
    • Ambient Air Temperature For Operation : -10-55 °C
    • Ambient Air Temperature For Storage : -20-85 °C
    • Environmental Disclosure : ENVPEP1406025_V3
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Relative Humidity : 10-95 %
    • Pep Code : ENVPEP1406025_V3
    • Pep Verification Date : 2026-01-15
    • Pcr Version : PCR-ed4-FR-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : safe relay output module
    • Range Of Product : Preventa Safety automation
  • ETIM
    • ETIM 8 : EC001449
    • ETIM 9 : EC001449
  • Output Attributes
    • Discrete Output Number : 8-8 solid state 125 mA diagnostics)
    • Number Of Outputs : 4 relay
    • Output Type : relay, 4 NO, volt-free
  • Specifications
    • Depth : 114.5 mm