Safety controller, Modicon MCM, 8 inputs 2 outputs, monitors expansion modules, spring

Controller with 8 inputs 2 out

SQDXPSMCMCP0802G XPSMCMCP0802G 3606480748554
649.00 / EA
http://schema.org/OutOfStock
  • Country of Origin: Italy
  • Depth: 114.5 mm
  • Number of Outputs: Safety Outputs OSSD Contactor/drive Connection, 4 Test Line Control Outputs Configurable Diagnostic Connection, 2
This Modicon MCM safety controller CPU is supplied with 24Vdc, has 8 safe digital inputs, 2 start/restart interlock inputs, 2 output OSSD pairs, 4 test outputs and 2 status outputs and is fitted with captive spring clamp terminals. It embeds a Mini USB 2.0 connector to receive the configuration done with the software EcoStruxure Machine Expert - HVAC. It is an appropriate solution for machines with a small number of safety functions requiring the configuration flexibility of a safety controller. It can be used as standalone or with fourteen expansion modules. The system is expandable up to 128 inputs, 16 outputs and up to 32 diagnostic status outputs, ideal for machines requiring multiple safety function monitoring. This safety controller CPU figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, communication, master enable, restart signal, output channels). It is a CPU with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. It weighs 0.25kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safety controller CPU instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
QTY
  • Features
  • Specifications
  • Features
    • Modular safety controller are designed to provide safety solutions requiring conformity to PLe and SIL3
    • Reduce time-to-market: Offers designed specifically meeting the 6 safety functions required on your machine
    • Modicon MCM offers an extensive range of safety products designed to provide protection for personnel and equipment
    • Modicon MCM safety controller are designed for monitoring multiple safety functions
    • Increase profitability: Safety designed from standalone components to embedded safety network solutions
    • Improve efficiency: One partner for the complete safety chain covering the complete range of safety functions
    • Simplify integration: Wide range of connections for machine controllers
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Integrated Connection Type : backplane expansion bus, USB 2.0 port
    • Uimp Rated Impulse Withstand Voltage : 4 kV IEC 61800-5-1
    • Us Rated Supply Voltage : 24 V - 20...20 % DC
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Cable Cross Section : 0.25-2.5 mm² - 23 AWG...14 AWG solid without cable end, 0.2-2.5 mm² - 24 AWG...14 AWG flexible without cable end, 0.25-2.5 mm² - 23 AWG...14 AWG flexible with cable end, with bezel, 0.2-2.5 mm² - 24 AWG...14 AWG solid without cable end, 0.25-2.5 mm² - 23 AWG...14 AWG flexible with cable end, without bezel, 0.5-1 mm² - 20 AWG...18 AWG flexible with cable end, with double bezel
    • Function Of Module : light curtain monitoring EN/ISO 14119, emergency stop ISO 13850guard monitoring EN/ISO 14119enabling switch monitoring IEC 60947-5-1light curtain monitoring IEC 61496-1, foot switch monitoring IEC 60947-5-1switch monitoring EN 574, two-hand control EN/ISO 14119safety mat monitoring IEC 61326-1, switch monitoring IEC 61800-5-2, muting function of light curtains IEC 61800-5-2, safety time delays, counter functions
    • Local Signalling : 1 LED green PWR power ON1 LED green RUN RUN (status), 1 LED red E IN internal error1 LED red E EX external error, 1 LED orange COM communication, 1 LED blue EN master enable8 LEDs yellow IN input status2 LEDs green/red OUT output status2 LEDs yellow RST restart signal2 LEDs yellow STATUS output channel
    • Safety Level : can reach category 4 ISO 13849-1, can reach PL = e ISO 13849-1type 4 IEC 61496-1SILCL 3 IEC 62061
    • Safety Reliability Data : PFHd = 6.06E-9 1/h, DC > 99 %MTTFd < 100 years high
    • Vibration Resistance : +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1+/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1
    • Connections Terminals : 1 spring terminals, removable terminal block, 2 spring terminals, removable terminal block
    • Certificate Agency : RCM, TÜV, cULus
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-25
    • Return Indicator : Y
    • Device Type : PLC System - PLC CPU
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1847
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : Yes
    • China Rohs Label : e
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Data Storage Equipment : SD card optional)
    • Device Short Name : XPSMCM
    • Electrical Connection : spring terminal
    • Electromagnetic Compatibility : electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
    • Inductive Load : 30 mH
    • Insulation : 250 V AC between power supply and housing IEC 61800-5-1
    • Load Capacitance : 0.82 µF
    • Mounting Support : omega 35 mm DIN rail EN 50022
    • Overvoltage Category : II
    • Power Dissipation In W : 3 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : safety controller CPU
    • Quality Labels : CE
    • Range Of Product : Modicon Safety automation
    • Returnability : Yes
    • Service Life : 20 year(s)
    • Shock Resistance : 10 gn 16 ms) 1000 shocks on each axis IEC 61496-1
    • Sustainable Packaging : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Height Nominal : 99 mm
    • Width Nominal : 22.5 mm
    • Maximum Number Of I/O Expansion Module : 14 128 input14 16 output
    • Nbr. Of Units In Pkg. : 1
    • Customs Code : 8537109160
    • Warranty In Months : 18
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -10-55 °C, -10-55 °C
    • Ambient Air Temperature For Storage : -20-85 °C, -20-85 °C
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Relative Humidity : 10-95 %
  • General Attributes
    • Product Or Component Type : safety controller CPU
    • Range Of Product : Modicon Safety automation
  • ETIM
    • ETIM 8 : EC001449
    • ETIM 9 : EC001449
    • ETIM 10 : EC001449
  • Output Attributes
    • Number Of Outputs : safety outputs OSSD contactor/drive connection, 4 test line control outputs configurable diagnostic connection, 2
    • Discrete Output Current : 400 mA
    • Discrete Output Type : PNP
  • Input Attributes
    • Discrete Input Type : safety input, PNP
    • Synchronisation Time Between Inputs : < 0.5 ms, < 0.5 ms
    • Discrete Input Current : 400 mA
    • Discrete Input Voltage : 24 V
    • Number Of Inputs : 8 digital input connection2 digital interlock start/restart or external device monitoring
  • Specifications
    • Country of Origin : Italy
    • Depth : 114.5 mm