contactor, TeSys F, 3P(3NO), AC-3, <=440V 115A, coil 600V AC

contactor, TeSys F, 3P(3NO), A

SQDLC1F115X7 LC1F115X7 3606481734143
0.00 / EA
http://schema.org/OutOfStock
  • Certifications: ABS, BV, CB, CCC, DNV, LROS (Lloyds Register Of Shipping), RINA, RMRoS, UL
  • Contact Configuration: 3 NO
  • Depth: 171 mm
  • Height: 162 mm
  • Impedance: 0.37 MOhm - Ith 200 A 50 Hz
  • Net Weight: 3.43 kg
  • Standard: EN 60947-1, EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, JIS C8201-4-1
  • Storage Temperature: -60-80 °C
  • Width: 163.3 mm
QTY
  • Specifications
  • Complementary
    • Product Certifications : RINA || BV || RMRoS || CB || LROS (Lloyds register of shipping) || DNV || UL || CCC || ABS
    • Power Dissipation Per Pole : 15 W AC-1 || 5 W AC-3
    • Average Impedance : 0.37 mOhm - Ith 200 A 50 Hz
    • [Ith] Conventional Free Air Thermal Current : 200 A (at 40 °C)
    • Control Circuit Voltage Limits : operational 0.85...1.1 Uc 40...400 Hz 55 °C) || drop-out 0.2...0.55 Uc 40...400 Hz 55 °C)
    • Standards : IEC 60947-4-1 || IEC 60947-1 || EN 60947-4-1 || EN 60947-1 || JIS C8201-4-1
    • Mounting Support : plate
    • Control Circuit Type : AC 40...400 Hz
    • Contactor Coil Voltage : 600 V AC standard
    • Rated Breaking Capacity : 920 A conforming to IEC 60947-4-1
    • Associated Fuse Rating : 125 A aM at <= 440 V || 200 A gG at <= 440 V
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV
    • Inrush Power In Va : 690-855 VA, 40...400 Hz 0.9 20 °C)
    • Connections - Terminals : power circuit bar 2 20 x 3 mm || power circuit lugs-ring terminals 1 95-95 mm² || power circuit connector 1 95-95 mm² || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit bolted connection
    • Pole Contact Composition : 3 NO
    • Operating Time : 35 ms closing at Uc) || 130 ms opening at Uc)
    • Maximum Operating Rate : 1200 cyc/h 55 °C
    • Mechanical Durability : 10 Mcycles
    • Tightening Torque : power circuit 10 N.m || control circuit 1.2 N.m
    • Compatibility Code : LC1F
    • Hold-In Power Consumption In Va : 6.6-8.1 VA, 40...400 Hz 0.9 20 °C)
    • Overvoltage Category : III
    • Motor Power Kw : 55 kW at 380...400 V AC 50/60 Hz (AC-3) || 59 kW at 415 V AC 50/60 Hz (AC-3) || 59 kW at 440 V AC 50/60 Hz (AC-3) || 75 kW at 500 V AC 50/60 Hz (AC-3) || 80 kW at 660...690 V AC 50/60 Hz (AC-3) || 30 kW at 220...230 V AC 50/60 Hz (AC-3) || 18.5 kW at 400 V AC 50/60 Hz (AC-4)
    • [Ui] Rated Insulation Voltage : 1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
    • [Icw] Rated Short-Time Withstand Current : 1100 A 40 °C - 10 s || 640 A 40 °C - 30 s || 520 A 40 °C - 1 min || 400 A 40 °C - 3 min || 320 A 40 °C - 10 min
    • Heat Dissipation : 5.9-7.2 W
  • Environment
    • Ambient Air Temperature For Operation : -40-60 °C
    • Height : 162 mm
    • Net Weight : 3.43 kg
    • Ambient Air Temperature For Storage : -60-80 °C
    • Protective Treatment : TH
    • Ip Degree Of Protection : IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
    • Operating Altitude : 9842.52 ft (3000 m) without derating
    • Width : 163.3 mm
    • Depth : 171 mm
    • Permissible Ambient Air Temperature Around The Device : 60-70 °C at Uc
  • Specifications
    • [Uc] Control Circuit Voltage : 600 V AC 40...400 Hz
    • Range Of Product : TeSys F
    • [Ue] Rated Operational Voltage : <= 690 V AC 50/60 Hz
    • Contactor Application : resistive load || motor control
    • Product Or Component Type : contactor
    • Range : TeSys
    • Utilisation Category : AC-3 || AC-1 || AC-4
    • [Ie] Rated Operational Current : 200 A (at <40 °C) at <= 440 V AC-1 || 115 A (at <55 °C) at <= 440 V AC-3
    • Poles Description : 3P
    • Device Short Name : LC1F
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Eu Rohs Directive : Compliant with Exemptions