Harmony, 3 phase supply control relay, range 220 to 480 VAC, sequence, phase failure, phase imbalance, voltage

3 PHASE RELAY 250V 5AMP RM35

SQDRM35TF30 RM35TF30 3389119405263
346.86 / EA
http://schema.org/OutOfStock
  • Height: 3.54 in
  • Operating Position: Any Position Without Derating
  • Warranty Length: 18 mth
  • Width: 1.38 in
Harmony Control Monitoring and Control Relays (RM17, RM22, RM35) monitor and detect abnormal operating conditions concerning phase ,current, voltage, frequency, speed, or temperature. The relays inform users of abnormal conditions and allow them to initiate the necessary corrective actions before serious and costly breakdown can occur. Harmony phase control relays detect all possible faults occurring in the phases. Harmony voltage and current control relays ensure your equipment is powered with proper values. Harmony frequency control relay monitors frequency variation from your power generation line. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Harmony pump control relay controls and protects your pump from dry running or overloading. Harmony speed control relay picks up the improper rhythm of your process. Harmony temperature control relay for lift application is a dedicated to elevator temperature monitoring (EN81). Harmony temperature control relays are dedicated to temperature regulation (heating, cooling or heating/cooling of processes). These Harmony relays are available in 17.5 mm, 22.5 mm or 35 mm wide housings and are DIN rail mounted. Applications for these Harmony relays include hoisting, construction cranes, harbor cranes, packaging, construction elevators, passenger elevators, escalators, textile, water and waste water. 0 0 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
Harmony Control Monitoring and Control Relays (RM17, RM22, RM35) monitor and detect abnormal operating conditions concerning phase ,current, voltage, frequency, speed, or temperature. The relays inform users of abnormal conditions and allow them to initiate the necessary corrective actions before serious and costly breakdown can occur. Harmony phase control relays detect all possible faults occurring in the phases. Harmony voltage and current control relays ensure your equipment is powered with proper values. Harmony frequency control relay monitors frequency variation from your power generation line. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Harmony pump control relay controls and protects your pump from dry running or overloading. Harmony speed control relay picks up the improper rhythm of your process. Harmony temperature control relay for lift application is a dedicated to elevator temperature monitoring (EN81). Harmony temperature control relays are dedicated to temperature regulation (heating, cooling or heating/cooling of processes). These Harmony relays are available in 17.5 mm, 22.5 mm or 35 mm wide housings and are DIN rail mounted. Applications for these Harmony relays include hoisting, construction cranes, harbor cranes, packaging, construction elevators, passenger elevators, escalators, textile, water and waste water. 0 0 0 0 0 0 0
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Control Circuit Voltage Limits : - 12 % + 10 % Un, - 12 % + 10 % Un
    • Maximum Switching Current : 5 A AC, 5 A DC
    • Control Circuit Frequency : 50...60 Hz +/- 10 %
    • Line Rated Current : 5 A
    • Maximum Measuring Cycle : 140 ms measurement cycle as true rms value
    • Maximum Switching Voltage : 250 V AC
    • Minimum Switching Current : 10 mA 5 V DC
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Insulation Resistance : > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5> 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5
    • Local Signalling : LED (green) for power ONLED (yellow) for relay ON, LED (yellow) for fault
    • Measurement Error : < 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation< 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation0.05 %/°C with temperature variation
    • Relay Monitored Parameters : asymmetry, undervoltage and overvoltage in window mode, phase sequence, phase failure detection, asymmetry
    • Response Time : < 200 ms (in the event of a fault), < 200 ms (in the event of a fault)< 200 ms (in the event of a fault), < 200 ms (in the event of a fault)
    • Safety Reliability Data : MTTFd = 399.5 years, B10d = 360000
    • Threshold Adjustment Voltage : -12...-2 % in the range 220 V AC, +2...+10 % in the range 480 V AC, 2...20 % of Un selected, -12...-2 % in the range 220 V AC, +2...+10 % in the range 480 V AC
    • Vibration Resistance : 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6, 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1
    • Certificate Agency : GL, UL, CSA, GOST, C-tick
    • Connections - Terminals : screw connectors, screw terminals, 1 x 0.5...1 x 4 mm² 20 AWG...11 AWG) solid without cable endscrew terminals, 2 x 0.5...2 x 2.5 mm² 20 AWG...14 AWG) solid without cable endscrew terminals, 1 x 0.2...1 x 2.5 mm² 24 AWG...12 AWG) flexible with cable endscrew terminals, 2 x 0.2...2 x 1.5 mm² 24 AWG...16 AWG) flexible with cable end
    • Carbon Footprint Of The Distribution Phase [A4] : 0.0167723636, 0 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 0.0755394545, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0 kg CO2 eq., 0.0006485936
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 3 kg CO2 eq., 2.6720909091
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 93 kg CO2 eq., 92.70576
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Weee Scope : Out
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1601004EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1918
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Adjustment Of Asymmetry Threshold : 5...15 % of Un selected
    • Compatibility Code : RM3
    • Contacts Type And Composition : 2 C/O
    • Control Type : without test button
    • Dielectric Test Voltage : 2 kV AC 50 Hz, 1 min
    • Electrical Durability : 100000 cycles
    • Electromagnetic Compatibility : emission standard for industrial environments conforming to IEC 61000-6-4emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3immunity for industrial environments conforming to IEC 61000-6-2
    • Housing Material : polycarbonate
    • Hysteresis : 2-2 %
    • Marking : CE
    • Measurement Range : 220...480 V AC
    • Measurement Voltage Limits : 176-528 V AC
    • Mechanical Durability : 30000000 cycles
    • Mounting Support : 35 mm symmetrical DIN rail conforming to IEC 60715
    • Operating Position : any position without derating
    • Overvoltage Category : III conforming to IEC 60664-1
    • Power Consumption In Va : 0-22 VA 400 V AC 50 Hz
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : 3-phase control relay
    • Product Specific Application : for 3-phase supply
    • Range Of Product : Harmony Control Relays
    • Relay Name : RM35TF
    • Relay Type : multifunction control relay
    • Reset Time : 1500 ms at 480 V
    • Returnability : Yes
    • Setting Accuracy Of Time Delay : 10 %
    • Software Version : EIME v5.8.1
    • Supply Frequency : 50/60 Hz +/- 10 %
    • Supply Voltage Limits : 194-528 V AC, 3 phase
    • Sustainable Packaging : Yes
    • Switching Capacity In Va : 1250 VA
    • Tightening Torque : 0.6-1 N.m IEC 60947-1
    • Time Delay Type : adjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault
    • Total Lifecycle Carbon Footprint : 95 kg CO2 eq.
    • Voltage Detection Threshold : < 194 V< 194 V
    • Contacts Composition : 2 C/O
    • Measurement Range 4 : 220...480 V AC
    • Pep Code : ENVPEP1601004EN
    • Database Version : 2016-11
    • Pep Verification Date : 2019-05-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : To switch ON/OFF electrical contacts when the abnormal operating conditions is detected during 10 years and a 100% use rate.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unité (unit)
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 189.216
    • Energy Model - Manufacturing [A1-a3] : Energy model used: Indonesia
    • Energy Model - Installation [A5] : Electricity mix; AC; <lt/> 1kV; EU-27
    • Energy Model - Use [B6] : Electricity mix; AC; <lt/> 1kV; EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity mix; AC; <lt/> 1kV; EU-27
    • Recyclability Potential In % : 8
    • Height Nominal : 90 mm
    • Height Useful : 90 mm
    • Width Nominal : 35 mm
    • Width Real : 35 mm
    • [Uc] Control Circuit Voltage : 220...480 V
    • [Ui] Rated Insulation Voltage : 400 V IEC 60664-1
    • [Us] Rated Supply Voltage : , self-powered, self-powered
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 131.000 g
    • Take-back : No
    • Warranty (In Months) : 18
    • Air Pollution (M3) Operational Energy Use [B6] : 3990.096
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 1052.28
    • Net Use Of Fresh Water (M3) Operational Energy Use [B6] : 336.1392
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 345.6432
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 1616.112
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 1851.552
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 235.44
    • Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1616.112
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 235.44
    • Water Pollution (M3) Operational Energy Use [B6] : 3825.36
    • Customs Code : 8537109170
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-70 °C, -40-158 °F, -40-70 °C, -40-158 °F
    • Directives : 89/336/EEC - electromagnetic compatibility, 73/23/EEC - low voltage directive
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 95.4708113209
    • Ambient Air Temperature For Operation : -20-50 °C-20-50 °C
    • Circularity Profile : ENVEOLI1601004EN
    • Environmental Disclosure : ENVPEP1601004EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 IEC 60529 terminals)IP30 IEC 60529 casing)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 95-95 % 55-55 °C IEC 60068-2-30
    • Pep Code : ENVPEP1601004EN
    • Pep Verification Date : 2019-05-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : 3-phase control relay
    • Range Of Product : Harmony Control Relays
  • ETIM
    • ETIM 8 : EC001441
    • ETIM 9 : EC001441
  • Output Attributes
    • Nominal Output Current : 5 A
    • Output Contacts : 2 C/O
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Height : 3.54 in
    • Width : 1.38 in
    • Country of Origin : Brazil, France, Indonesia, Mexico, Singapore, United States