Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 10 HP, 5 kA SSCR, 30A fuse clip, IEC bimetallic overload, 440/480 VAC 50/60 Hz coil, NEMA 3R

PUMP PANEL

SQD8940SSC4010B1210HP 8940SSC4010B1210HP 785901591115
2074.05 / EACH
http://schema.org/OutOfStock
  • Certifications: NEMA, UL Listed
  • Depth: 246 mm
  • Fuse Type: H Or K
  • Height: 992 mm
  • Line Rated Current: 27 A
  • Mounting Type: Surface
  • Number of Poles: 3
  • Warranty Length: 18 mth
  • Width: 385 mm
Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a 30A fusible disconnect switch for Class H or K fuses. This panel has a 3 pole NEMA Size 1 non-reversing starter that has a 27 ampere rating. This NEMA Size 1 starter has maximum of 10 HP rating three phase. This non-reversing NEMA motor starter has an IEC ambient compensated bimetallic overload relay to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 440/480 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 39.05 inches tall, 13.73 inches wide and 9.70 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
QTY
  • Product Description
  • Specifications
Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a 30A fusible disconnect switch for Class H or K fuses. This panel has a 3 pole NEMA Size 1 non-reversing starter that has a 27 ampere rating. This NEMA Size 1 starter has maximum of 10 HP rating three phase. This non-reversing NEMA motor starter has an IEC ambient compensated bimetallic overload relay to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 440/480 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 39.05 inches tall, 13.73 inches wide and 9.70 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
  • Specifications
    • Product Name : Well-Guard Control
    • Device Application : pumping
    • Device Short Name : class 8940 type SS
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Thermal Overload Type : ambient compensated bimetallic
    • Disconnector Device Type : fusible disconnect switch
    • Height : 992 mm
    • Control Type : selector switch HAND-OFF-AUTO) || push-button START)
    • Nema Size : 1
    • Device Mounting : surface
    • Fuse Type : H or K
    • Maximum Horse Power Rating : 10-10 hp 480 V AC, 3 phase
    • [Uc] Control Circuit Voltage : 480 V AC 60 Hz || 440 V AC 50 Hz
    • Electrical Connection : screw terminal
    • Line Rated Current : 27 A
    • Protection Type : overload || phase loss || phase unbalance
    • Control Circuit : common control circuit
    • Width : 385 mm
    • Depth : 246 mm
    • Permissible Voltage : 600 V AC
    • Associated Fuse Rating : 30 A
    • Number Of Poles : 3
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Pvc Free : Yes
    • Eu Rohs Directive : Not compliant
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : UL Listed || NEMA
    • Nema Degree Of Protection : NEMA 3R
    • Enclosure Type : weatherproof enclosure indoor/outdoor