variable speed drive, Altivar Process ATV900, ATV930, 3kW, 380 to 480V, cabinet Integration, IP20, for US

VARIABLE SPEED DRIVE, ALTIVAR

SQDATV930U30N4ZU ATV930U30N4ZU 3606489740214
1878.02 / EA
http://schema.org/OutOfStock
  • Connection Type: 1 RJ45, 2 RJ45
  • Country of Origin: Indonesia
  • Depth: 196 mm
  • Height: 285 mm
  • Operating Position: Vertical +/- 10 Degree
  • Width: 130 mm
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Discrete Input Logic : positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
    • Power Dissipation In W : natural convection 31 W 380 V 4 kHz || forced convection 78 W 380 V 4 kHz
    • Analogue Output Type : software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
    • Discrete Output Type : logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
    • Maximum Switching Current : relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC || relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
    • 4 Quadrant Operation Possible : true
    • Exchange Mode : half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
    • Local Signalling : local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • With Safety Function Safe Direction (Sdi) : false
    • Relay Output Type : configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
    • Analogue Input Number : 3
    • Motor Slip Compensation : automatic whatever the load || not available in permanent magnet motor law || adjustable || can be suppressed
    • Discrete Output Number : 2
    • With Safety Function Safe Position (Sp) : false
    • Method Of Access : slave Modbus TCP
    • With Safety Function Safely Limited Position (Slp) : false
    • With Safety Function Safe Operating Stop (Sos) : false
    • Discrete Input Number : 10
    • Linearity Error : AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
    • Number Of Addresses : 1-247 Modbus serial
    • With Sft Fct Safe Stop 2 (Ss2) : false
    • With Safety Function Safe Stop 1 (Ss1) : true
    • Width : 130 mm
    • Transmission Rate : 10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
    • Depth : 196 mm
    • Analogue Input Type : AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
    • Sampling Duration : 2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
    • Electrical Connection : control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 2.5...6 mm² AWG 14...AWG 10 || motor screw terminal 2.5...6 mm² AWG 14...AWG 10 || DC bus screw terminal 2.5...6 mm² AWG 14...AWG 10
    • With Safety Function Safe Brake Management (Sbc/Sbt) : true
    • Height : 285 mm
    • Acceleration And Deceleration Ramps : linear adjustable separately from 0.01...9999 s
    • Maximum Output Voltage : 480.0 V
    • Base Load Current At High Overload : 5.6 A
    • Transmission Frame : RTU
    • With Safety Function Safe Speed Monitor (Ssm) : false
    • Relay Output Number : 3
    • With Safety Function Safe Torque Off (Sto) : true
    • Data Format : 8 bits, configurable odd, even or no parity
    • Base Load Current At Low Overload : 7.2 A
    • Accuracy : +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    • Input Compatibility : DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
    • Connector Type : 2 RJ45 || 1 RJ45
    • Analogue Output Number : 2
    • Physical Interface : Ethernet || 2-wire RS 485
    • Minimum Switching Current : relay output R1, R2, R3 5 mA 24 V DC
    • Refresh Time : relay output R1, R2, R3)5 ms +/- 0.5 ms)
    • Isolation : between power and control terminals
    • With Safety Function Safe Programmable Logic : false
    • Brake Chopper Integrated : true
    • Quantity Per Set : 1
    • Type Of Polarization : no impedance Modbus serial
    • Braking To Standstill : by DC injection
    • Discrete Input Type : DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
    • Protection Type : thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive
    • Supply : external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection
    • With Safety Function Safely Limited Speed (Sls) : true
  • Specifications
    • Country of Origin : Indonesia
    • Width : 130 mm
    • Height : 285 mm
    • Prospective Line Isc : 50 kA
    • Network Frequency : 50-60 Hz
    • Product Destination : asynchronous motors || synchronous motors
    • Line Current : 5.8 A 380 V normal duty) || 4.5 A 380 V heavy duty) || 5.1 A 480 V normal duty) || 4.0 A 480 V heavy duty)
    • Phase : 3 phase
    • Asynchronous Motor Control Profile : variable torque standard || constant torque standard || optimized torque mode
    • Variant : with braking chopper || standard version
    • Product Or Component Type : variable speed drive
    • Apparent Power : 4.2 kVA 480 V normal duty) || 3.3 kVA 480 V heavy duty)
    • Ip Degree Of Protection : IP21
    • Switching Frequency : 2...16 kHz adjustable || 4...16 kHz with derating factor
    • Maximum Transient Current : 8.6 A 60 s normal duty) || 8.4 A 60 s heavy duty)
    • Communication Port Protocol : Modbus serial || EtherNet/IP || Modbus TCP
    • Product Specific Application : process for industrial
    • Option Card : slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module CANopen SUB-D 9 || slot A communication module CANopen screw terminals || slot A/slot B/slot C digital and analog I/O extension module || slot A/slot B/slot C output relay extension module || slot B 5/12 V digital encoder interface module || slot B analog encoder interface module || slot B resolver encoder interface module || communication module Ethernet Powerlink
    • Degree Of Protection : UL type 12
    • Maximum Output Frequency : 599 Hz
    • Range Of Product : Altivar Process ATV900
    • Motor Power Kw : 3.0 kW normal duty || 2.2 kW heavy duty
    • [Us] Rated Supply Voltage : 380...480 V - 15...10 %
    • Mounting Mode : cabinet mount
    • Discrete Input Logic : 16 preset speeds
    • Continuous Output Current : 7.2 A 4 kHz normal duty || 5.6 A 4 kHz heavy duty
    • Nominal Switching Frequency : 4 kHz
    • Emc Filter : integrated || with EMC plate option
    • Device Application : Industrial Application
    • Synchronous Motor Control Profile : permanent magnet motor || synchronous reluctance motor
  • Environment
    • Product Certifications : TÜV || CSA || UL
    • Maximum Deflection Under Vibratory Load (During Operation) : 1.5 mm at 2...13 Hz
    • Standards : UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
    • Insulation Resistance : > 1 MOhm 500 V DC for 1 minute to earth
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27
    • Environmental Characteristic : chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
    • Vibration Resistance : 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6 || 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6
    • Regulation Loop : adjustable PID regulator
    • Permitted Relative Humidity (During Operation) : class 3K5 according to EN 60721-3
    • Operating Altitude : <= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
    • Overvoltage Category : III
    • Environmental Class (During Operation) : class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
    • Maximum Acceleration Under Shock Impact (During Operation) : 150 m/s² at 11 ms
    • Pollution Degree : 2
    • Electromagnetic Compatibility : electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 || conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    • Ambient Air Temperature For Operation : -15-50 °C (without derating) || 50-60 °C (with derating factor)
    • Volume Of Cooling Air : 38 m3/h
    • Marking : CE
    • Maximum Acceleration Under Vibrational Stress (During Operation) : 10 m/s² at 13...200 Hz
    • Noise Level : 54.5 dB
    • Ambient Air Temperature For Storage : -40-70 °C
    • Relative Humidity : 5-95 % without condensation IEC 60068-2-3
    • Assembly Style : with heat sink
    • Operating Position : vertical +/- 10 degree
    • Maximum Thdi : <48 % full load IEC 61000-3-12
    • Ambient Air Transport Temperature : -40-70 °C
  • Environmental data
    • Mercury Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Take-Back : No
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 3897.1368665951
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP2007009EN
    • Packaging Without Single Use Plastic : Yes
    • Scip Number : d9267909-b64a-464f-8f55-d6fd46285d0f
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI2007009EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)