Variable Speed Drive, Altivar Process ATV900, ATV930, 160kW, 400 to 480V, without braking unit, IP00

SPEEDDRIVE,IP00,250HP,400V/480

SQDATV930C16N4C ATV930C16N4C 3606480883477
30837.64 / EA
http://schema.org/OutOfStock
  • Connection Type: 2 RJ45, 1 RJ45
  • Depth: 393 mm
  • IsSustainable: Yes
  • Operating Position: Vertical +/- 10 Degree
This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 160kW/250HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 132kW/200HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380Vac to 480Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
QTY
  • Product Description
  • Features
  • Specifications
This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 160kW/250HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 132kW/200HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380Vac to 480Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
  • Features
    • Embedded power measurement and energy dashboard
    • Embedded process monitoring and control
    • Stop and Go function to reduce energy consumption
    • Asset monitoring and protection
    • Drift monitoring
    • Easy maintenance via a dynamic QR code
    • Proven technical cooling and harmonics solutions
    • Modular and compact design
    • Easy grid integration
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus serial, Modbus TCP, EtherNet/IP
  • Conformance Attributes
    • Product Certifications : UL, CSA, TÜV
    • Standards : UL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1
  • Complementary Attributes
    • Maximum Switching Current : relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC, relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R1 resistive, cos phi = 1 3 A 250 V AC, relay output R1 resistive, cos phi = 1 3 A 30 V DC, relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
    • Maximum Thdi : <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12
    • Maximum Transient Current : 362 A 60 s normal duty), 375 A 60 s heavy duty)
    • Brake Chopper Integrated : false
    • Maximum Input Current Per Phase : 284.0 A
    • Maximum Output Frequency : 599 Hz
    • Maximum Output Voltage : 480.0 V
    • Minimum Switching Current : relay output R1, R2, R3 5 mA 24 V DC
  • Important Information Attributes
    • Product Contributes To Saved And Avoided Emissions : YES_SSI2, Yes
    • Persona Type Ids : EU, OM, OM8, SI
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
    • Apparent Power : 201.3 kVA 480 V normal duty), 161.4 kVA 480 V heavy duty)
    • Asynchronous Motor Control Profile : variable torque standard, constant torque standard, optimized torque mode
    • Connector Type : 2 RJ45, 1 RJ45
    • Data Format : 8 bits, configurable odd, even or no parity Modbus serial, 8 bits, configurable odd, even or no parity
    • Electromagnetic Compatibility : electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    • EMC Filter : integrated, with EMC plate option
    • Encoder Protocol : 1 Vpp, EnDat 2.2, resolver, RS 422, SSI 24V, SSI 5V, TTL/HTL
    • Line Current : 284.0 A 380 V normal duty), 237.0 A 380 V heavy duty), 262.0 A 480 V normal duty), 213.0 A 480 V heavy duty)
    • Linearity Error : AI1, AI2, AI3 +/- 0.15 % of maximum value analog input, AQ1, AQ2 +/- 0.2 % analog output
    • Motor Power KW : 160.0 kW normal duty, 132.0 kW heavy duty
    • Motor Slip Compensation : automatic whatever the load, can be suppressed, adjustable, not available in permanent magnet motor law
    • Noise Level : 69.9 dB 86/188/EEC, 69.9 dB
    • Number Of Addresses : 1-247, 1-247 Modbus serial
    • Power Dissipation In W : forced convection 3507 W 380 V 2.5 kHz, natural convection 405 W 380 V 2.5 kHz
    • Product Destination : synchronous motors, asynchronous motors
    • Protection Type : safe torque off drive, motor phase break drive, thermal protection motor, safe torque off motor, motor phase break motor, thermal protection drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
    • Sampling Duration : 2 ms +/- 0.5 ms DI1...DI8) - discrete input, 5 ms +/- 1 ms DI7, DI8) - pulse input, 1 ms +/- 1 ms AI1, AI2, AI3) - analog input, 5 ms +/- 1 ms AQ1, AQ2) - analog output
    • Switching Frequency : 1...8 kHz adjustable, 2.5...8 kHz with derating factor
    • Synchronous Motor Control Profile : permanent magnet motor, synchronous reluctance motor
    • Transmission Rate : 10/100 Mbit/s Ethernet IP/Modbus TCP, 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial, 10, 100 Mbits, 4.8 kbps, 9600 bit/s, 19200 bit/s
    • Type Of Polarization : no impedance, no impedance Modbus serial
    • Ue Rated Operational Voltage2 : 380...480 V 160.0 kW 250 hp normal duty, 380...480 V 132.0 kW 200 hp heavy duty
    • Us Rated Supply Voltage2 : 380...480 V, 380...480 V - 15...10 %
    • Environmental Class During Operation2 : class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
    • Environmental Class During Storage2 : class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
    • Environmental Class During Transport2 : class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
    • Carbon Footprint Of The Distribution Phase A4 : 13.1032712, 13 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 18.250332, 18 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 7 kg CO2 eq., 7.04907648
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 655 kg CO2 eq., 654.899504
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 114 ton CO2 eq., 113986.310436477
    • Environmental Class During Operation3 : class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
    • Environmental Class During Storage3 : class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
    • Environmental Class During Transport3 : class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
    • Ue Rated Operational Voltage5 : 380...480 V 160.0 kW 250 hp normal duty, 380...480 V 132.0 kW 200 hp heavy duty
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Device Type : Variable speed drive - VSD Compacts
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2510019EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Return Indicator : Y
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Function Option Id : ADVANCED
    • Function Option : Advanced
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • 1 Phase Low Current Possible : false
    • 4 Quadrant Operation Possible : false
    • Application In Domestic And Commercial Area Permitted : false
    • Assembly Style : enclosed
    • Base Load Current At High Overload : 250.0 A
    • Base Load Current At Low Overload : 302.0 A
    • Braking To Standstill : by DC injection
    • Computer Port : true
    • Design Of Frequency Changer : U converter
    • Device Application : Industrial Application
    • Exchange Mode : half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
    • Housing Material : sheet steel
    • Isolation : between power and control terminals
    • Marking : CE
    • Maximum Input Current Per Phase : 284.0 A
    • Method Of Access : slave Modbus TCP
    • Mounting Mode : wall mount
    • Network Frequency : 50-60 Hz
    • Nominal Switching Frequency : 2.5 kHz
    • Operating Element Present : true
    • Operating Position : vertical +/- 10 degree
    • Optical Interface Present : false
    • Overvoltage Category : III
    • Package Weight Lbs : 89.800 kg
    • Phase : 3 phase
    • Power Loss Per Device Current Dependent : 3812.0 W
    • Power Loss Static Current Independent : 67.0 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : variable speed drive
    • Product Specific Application : process for industrial
    • Prospective Line Isc : 50 kA
    • Range Of Product : Altivar Process ATV900
    • Refresh Time : relay output R1, R2, R3)5 ms +/- 0.5 ms)
    • Regulation Loop : adjustable PID regulator
    • Relative Symmetric Mains Voltage Tolerance : 10 %
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • Returnability : Yes
    • Supporting Protocol For As Interface Safety At Work : false
    • Supporting Protocol For Asi : false
    • Supporting Protocol For Bacnet : false
    • Supporting Protocol For Can : true
    • Supporting Protocol For Data Highway : false
    • Supporting Protocol For Devicenet : false
    • Supporting Protocol For Devicenet Safety : false
    • Supporting Protocol For Ethernet Ip : true
    • Supporting Protocol For Foundation Fieldbus : false
    • Supporting Protocol For Interbus : false
    • Supporting Protocol For Knx : false
    • Supporting Protocol For Lon : false
    • Supporting Protocol For Modbus : true
    • Supporting Protocol For Other Bus Systems : false
    • Supporting Protocol For Profibus : true
    • Supporting Protocol For Profinet Cba : true
    • Supporting Protocol For Profinet Io : true
    • Supporting Protocol For Profisafe : false
    • Supporting Protocol For Safetybus P : false
    • Supporting Protocol For Sercos : false
    • Supporting Protocol For Suconet : false
    • Supporting Protocol For TCP IP : true
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 115 ton CO2 eq.
    • Transmission Frame : RTU
    • Volume Of Cooling Air : 600 m3/h
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • Emc Limit Value Complied2 : true
    • Maximum Acceleration Under Shock Impact During Operation2 : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Storage2 : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Transport2 : 150 m/s² at 11 ms
    • Maximum Acceleration Under Vibrational Stress During Operation2 : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Storage2 : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Transport2 : 10 m/s² at 13...200 Hz
    • Maximum Deflection Under Vibratory Load During Operation2 : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Storage2 : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Transport2 : 1.5 mm at 2...13 Hz
    • Permitted Relative Humidity During Operation2 : class 3K5 according to EN 60721-3
    • Permitted Relative Humidity During Storage2 : class 1K5 according to EN 60721-3
    • Permitted Relative Humidity During Transport2 : class 2K5 according to EN 60721-3
    • With Safety Function Safe Brake Management Sbc Sbt2 : true
    • With Safety Function Safe Direction Sdi2 : false
    • With Safety Function Safe Operating Stop Sos2 : false
    • With Safety Function Safe Position Sp2 : false
    • With Safety Function Safe Speed Monitor Ssm2 : false
    • With Safety Function Safe Stop 1 SS1 : true
    • With Safety Function Safe Torque Off Sto2 : true
    • With Safety Function Safely Limited Position Slp2 : false
    • With Safety Function Safely Limited Speed Sls2 : true
    • With Sft Fct Safe Stop 2 Ss : false
    • Application In Industrial Area Permitted : true
    • Supporting Protocol For Interbus Safety : false
    • Medium Desc : Variable Speed Drive, Altivar Process ATV900, ATV930, 160kW, 400 to 480V, without braking unit, IP00
    • Stocking Flag : N
    • Product Kit Identifier : N
    • Emc Limit Value Complied3 : true
    • Maximum Acceleration Under Shock Impact During Operation3 : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Storage3 : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Transport3 : 150 m/s² at 11 ms
    • Maximum Acceleration Under Vibrational Stress During Operation3 : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Storage3 : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Transport3 : 10 m/s² at 13...200 Hz
    • Maximum Deflection Under Vibratory Load During Operation3 : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Storage3 : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Transport3 : 1.5 mm at 2...13 Hz
    • Permitted Relative Humidity During Operation3 : class 3K5 according to EN 60721-3
    • Permitted Relative Humidity During Storage3 : class 1K5 according to EN 60721-3
    • Permitted Relative Humidity During Transport3 : class 2K5 according to EN 60721-3
    • With Safety Function Safe Brake Management Sbc Sbt3 : true
    • With Safety Function Safe Direction Sdi3 : false
    • With Safety Function Safe Operating Stop Sos3 : false
    • With Safety Function Safe Position Sp3 : false
    • With Safety Function Safe Speed Monitor Ssm3 : false
    • With Safety Function Safe Torque Off Sto3 : true
    • With Safety Function Safely Limited Position Slp3 : false
    • With Safety Function Safely Limited Speed Sls3 : true
    • With Sft Fct Safe Stop 2 Ss4 : false
    • Pep Code : ENVPEP2510019EN
    • Database Version : 2016-11
    • Pep Verification Date : 2021-01-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 160 kW electric motors for fluid management and industrial applications in IP21 conditions, at 380V to 480V rated 3-phase voltage supply. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Energy model used: China
    • Energy Model Installation A5 2 : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model Use B6 2 : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; AC; < 1kV; EU-27
    • Global Commercial Status : Commercialised
    • Us Rated Supply Voltage5 : 380...480 V - 15...10 %
    • With Safety Function Safe Stop 1 Ss1 5 : true
  • Environment Attributes Main
    • Take Back : Nej, No
    • Ambient Air Temperature For Operation : -15-50 °C (without derating), -15-50 °C (without derating), -15-60 °C, -15-50 °C (without derating), -15-50 °C (without derating), 50-60 °C (with derating factor)
    • Ambient Air Transport Temperature : -40-70 °C, -40-70 °C
    • EU ROHS Directive : Compliant By Exemption , Pro-active compliance (Product out of EU RoHS legal scope)
    • Operating Altitude : <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, 1000...4800 m with current derating 1 % per 100 m
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 114679.612620157
    • Ambient Air Temperature For Storage : -40-70 °C
    • Circularity Profile : ENVEOLI2510019EN
    • Environmental Disclosure : ENVPEP2510019EN
    • IP Degree Of Protection : IP21
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2510019EN
    • Pep Verification Date : 2021-01-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : variable speed drive
    • Range Of Product : Altivar Process ATV900
  • Output Attributes
    • Analogue Output Type : software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
    • Continuous Output Current : 302 A 2.5 kHz normal duty, 250 A 2.5 kHz heavy duty
    • Discrete Output Type : logic output DQ+ 0-1 kHz <= 30 V DC 100 mA, programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA, logic output DQ- 0-1 kHz <= 30 V DC 100 mA
    • Relay Output Type : configurable relay logic R1 fault relay NO/NC 100000 cycles, configurable relay logic R2 sequence relay NO 1000000 cycles, configurable relay logic R3 sequence relay NO 1000000 cycles
    • Analogue Output Number : 2
    • Discrete Output Number : 2
    • Maximum Output Frequency : 599 Hz
    • Maximum Output Voltage : 480.0 V
    • Nominal Output Current : 302.0 A
    • Nominal Output Power : 160.0 W
    • Relay Output Number : 3
  • Surge Protection And Filtering Attributes
    • EMC Filter : integrated, with EMC plate option
  • Input Attributes
    • Analogue Input Type : AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
    • Discrete Input Type : DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm, DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V), STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
    • Input Compatibility : DI1...DI8 discrete input level 1 PLC IEC 61131-2, DI7, DI8 pulse input level 1 PLC IEC 65A-68, STOA, STOB discrete input level 1 PLC IEC 61131-2
    • Analogue Input Number : 3
    • Discrete Input Logic : 16 preset speeds
    • Discrete Input Number : 10
    • Number Of Input Phases : 3
  • Specifications
    • Depth : 393 mm
  • Batteries & Runtime Attributes
    • Removable Battery : Yes