variable speed drive, Altivar Process ATV600, ATV650, 45kW, 400...480V, IP55

DRIVE INVERTER VFD 3PH.48-63HZ

SQDATV650D45N4U ATV650D45N4U 3606480906909
8223.43 / EA
http://schema.org/OutOfStock
  • Connection Type: RJ45 On The Remote Graphic Terminal)Modbus Serial, RJ45 On The Remote Graphic Terminal)Ethernet/Modbus TCP
  • Country of Origin: China
  • Depth: 340 mm
  • IsSustainable: Yes
  • Operating Position: Vertical +/- 10 Degree
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus TCP, Modbus serial, Ethernet
  • Complementary Attributes
    • Maximum Horse Power Rating : 50 hp heavy duty, 60 hp normal duty
    • Maximum Switching Current : relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V ACrelay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC, relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
    • Maximum Thdi : <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12
    • Maximum Transient Current : 111.8 A 60 s heavy duty), 96.8 A 60 s normal duty)
    • Brake Chopper Integrated : false
    • Maximum Associated Fuse Rating : 160.0 A
    • Maximum Input Current Per Phase : 79.8 A
    • Maximum Output Frequency : 500 kHz
    • Maximum Output Voltage : 480.0 V
    • Minimum Switching Current : relay output R1, R2, R3 5 mA 24 V DC
  • Important Information Attributes
    • Product Contributes To Saved And Avoided Emissions : YES_SSI2, Yes
    • Persona Type Ids : EU, OM, OM8, SI
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
    • Apparent Power : 49.1 kVA 480 V heavy duty), 57.4 kVA 480 V normal duty)
    • Asynchronous Motor Control Profile : constant torque standard, optimized torque mode, variable torque standard
    • Connector Type : RJ45 on the remote graphic terminal)Modbus serial, RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
    • Electrical Connection : line side screw terminal 35...50 mm², motor screw terminal 35...50 mm², control removable screw terminals 0.5...1.5 mm² 20 AWG...16 AWG
    • Electromagnetic Compatibility : radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    • Emc Filter : integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
    • Frequency Resolution : analog input 0.012/50 Hz, display unit 0.1 Hz
    • Insulation Resistance : > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth> 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth
    • Line Current : 69.1 A 480 V normal duty), 67.1 A 380 V heavy duty), 59 A 480 V heavy duty), 79.8 A 380 V normal duty)
    • Linearity Error : AO1, AO2 +/- 0.2 % analog output, AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
    • Local Signalling : 3 LEDs (dual colour) for embedded communication status, 4 LEDs (dual colour) for communication module status, 1 LED (red) for presence of voltage, 3 LEDs for local diagnostic
    • Motor Power Kw : 37 kW heavy duty), 45 kW normal duty)
    • Motor Slip Compensation : adjustable, can be suppressed, not available in permanent magnet motor law, automatic whatever the load
    • Noise Level : 69.7 dB 86/188/EEC, 69.7 dB
    • Option Card : slot A communication module, PROFINET, slot A communication module, DeviceNet, slot A communication module, Modbus TCP/EtherNet/IP, slot A communication module, CANopen daisy chain RJ45, slot A communication module, CANopen SUB-D 9, slot A communication module, CANopen screw terminals, slot A/slot B digital and analog I/O extension module, slot A/slot B output relay extension module, slot A communication module, Ethernet IP/Modbus TCP/MD-Link, communication module, BACnet MS/TP, communication module, Ethernet Powerlink, slot A communication module, Profibus DP V1
    • Permissible Temporary Current Boost : 1.5 x In 60 s heavy duty), 1.1 x In 60 s normal duty)
    • Product Destination : asynchronous motors, synchronous motors
    • Protection Type : safe torque off drive, motor phase break drive, thermal protection motorsafe torque off motor, motor phase break motor, thermal protection drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
    • Sampling Duration : 5 ms +/- 1 ms DI5, DI6) - discrete input, 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input, 10 ms +/- 1 ms AO1) - analog output, 2 ms +/- 0.5 ms DI1...DI4) - discrete input
    • Supply : internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection, internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection, external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection
    • Switching Frequency : 4...12 kHz with derating factor, 2...12 kHz adjustable
    • Synchronous Motor Control Profile : synchronous reluctance motor, permanent magnet motor
    • Transmission Rate : 10, 100 Mbits, 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
    • Vibration Resistance : 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6, 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
    • Certificate Agency : ATEX INERIS, Bureau Veritas, ABS, DNV-GL, UL, TÜV
    • [Ue] Rated Operational Voltage : 380...480 V 45 kW 60 hp normal duty, 380...480 V 37 kW 50 hp heavy duty
    • [Us] Rated Supply Voltage : 380...480 V, 380...480 V - 15...10 %
    • Environmental Class (During Operation) : class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
    • Environmental Class (During Storage) : class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
    • Environmental Class (During Transport) : class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
    • Carbon Footprint Of The Distribution Phase [A4] : 10.153508910423685, 10 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 82.95898377604793, 83 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 34 kg CO2 eq., 34.18958135717863
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 468 kg CO2 eq., 467.78978103011394
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 12 445 kg CO2 eq., 12445.284635796534
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Variable speed drive - VSD Compacts
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 4
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1506001EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1923
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : ADVANCED
    • Function Option : Advanced
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • 1 Phase Low Current Possible : false
    • 4 Quadrant Operation Possible : false
    • Application In Domestic And Commercial Area Permitted : false
    • Base Load Current At High Overload : 74.5 A
    • Base Load Current At Low Overload : 88.0 A
    • Braking To Standstill : by DC injection
    • Capacity Of Dc Link : 3000.0 µF
    • Computer Port : true
    • Data Format : 8 bits, configurable odd, even or no parity
    • Design Of Frequency Changer : U converter
    • Device Short Name : ATV650
    • Enclosure Mounting : wall mounted
    • Exchange Mode : half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
    • Housing Material : sheet steel
    • Isolation : between power and control terminals
    • Marking : CE
    • Maximum Associated Fuse Rating : 160.0 A
    • Maximum Input Current Per Phase : 79.8 A
    • Method Of Access : slave Modbus TCP
    • Mounting Mode : wall mount
    • Network Frequency : 50-60 Hz
    • Nominal Switching Frequency : 4 kHz
    • Number Of Addresses : 1-247 Modbus serial
    • Number Of Hw Interfaces Industrial Ethernet : 1
    • Number Of Hw Interfaces Serial Rs485 : 1
    • Number Of Output Phases : 3
    • Operating Element Present : true
    • Operating Position : vertical +/- 10 degree
    • Optical Interface Present : false
    • Overvoltage Category : III
    • Phase : 3 phase
    • Power Loss Per Device Current Dependent : 1210.0 W
    • Power Loss Static Current Independent : 31.0 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : variable speed drive
    • Product Specific Application : process and utilities
    • Prospective Line Isc : 50 kA
    • Quantity Per Set : 1
    • Range Of Product : Altivar Process ATV600
    • Refresh Time : relay output R1, R2, R3)5 ms +/- 0.5 ms)
    • Regulation Loop : adjustable PID regulator
    • Relative Symmetric Mains Voltage Tolerance : 10 %
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • Returnability : Yes
    • Safety Function : STO (safe torque off) SIL 3
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27
    • Software Version : v6.2.5-6
    • Supply Frequency : 50...60 Hz - 5...5 %
    • Supporting Protocol For Asi : false
    • Supporting Protocol For Bacnet : false
    • Supporting Protocol For Can : true
    • Supporting Protocol For Devicenet : false
    • Supporting Protocol For Devicenet Safety : false
    • Supporting Protocol For Foundation Fieldbus : false
    • Supporting Protocol For Interbus : false
    • Supporting Protocol For Knx : false
    • Supporting Protocol For Lon : false
    • Supporting Protocol For Modbus : true
    • Supporting Protocol For Other Bus Systems : false
    • Supporting Protocol For Profibus : true
    • Supporting Protocol For Profinet Cba : true
    • Supporting Protocol For Profinet Io : true
    • Supporting Protocol For Profisafe : false
    • Supporting Protocol For Safetybus P : false
    • Supporting Protocol For Sercos : false
    • Supporting Protocol For Suconet : false
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 13 040 kg CO2 eq.
    • Transmission Frame : RTU
    • Type Of Cooling : forced convection
    • Type Of Polarization : no impedance
    • Updatability : Upgradeable through digital modules
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • Application In Industrial Area Permitted : true
    • Pep Code : ENVPEP1506001EN
    • Database Version : 2024-01
    • Pep Verification Date : 2026-05-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine's operating point for 45 kW for heavy duty electric motors for fluid management and industrial applications in IP55/UL type 1 conditions, at 380V to 480V rated 3-phases voltage supply. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 6% uptime in full phase, 15% uptime in medium high phase, 35% uptime in medium low phase and 44% uptime in low phase of the 5000h operating time and 1000h of standby according to the CEMEP guide: pump/fan/compressor.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 30790.057
    • Energy Model - Manufacturing [A1-a3] : Electricity mix; Production mix; low voltage; 2022; China, CN
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity mix; Production mix; low voltage; 2022; Europe, EU-27
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 89
    • Height Nominal : 910 mm
    • Width Nominal : 290 mm
    • Emc Limit Value (Complied) : true
    • Maximum Acceleration Under Shock Impact (During Operation) : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load (During Storage) : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load (During Transport) : 150 m/s² at 11 ms
    • Maximum Acceleration Under Vibrational Stress (During Operation) : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load (During Storage) : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load (During Transport) : 10 m/s² at 13...200 Hz
    • Maximum Deflection Under Vibratory Load (During Operation) : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load (During Storage) : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load (During Transport) : 1.5 mm at 2...13 Hz
    • Permitted Relative Humidity (During Operation) : class 3K5 according to EN 60721-3
    • Permitted Relative Humidity (During Storage) : class 1K5 according to EN 60721-3
    • Permitted Relative Humidity (During Transport) : class 2K5 according to EN 60721-3
    • Supporting Protocol For As-interface Safety At Work : false
    • Supporting Protocol For Data-highway : false
    • Supporting Protocol For Ethernet/Ip : true
    • Supporting Protocol For Interbus-safety : false
    • Supporting Protocol For Tcp/Ip : true
    • With Safety Function Safe Brake Management (Sbc/Sbt) : false
    • With Safety Function Safe Direction (Sdi) : false
    • With Safety Function Safe Operating Stop (Sos) : false
    • With Safety Function Safe Position (Sp) : false
    • With Safety Function Safe Speed Monitor (Ssm) : false
    • With Safety Function Safe Stop 1 (Ss1) : false
    • With Safety Function Safe Torque Off (Sto) : true
    • With Safety Function Safely Limited Position (Slp) : false
    • With Safety Function Safely Limited Speed (Sls) : false
    • With Sft Fct Safe Stop 2 (Ss2) : false
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 66.0 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8504404000
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -15-40 °C (without derating), -15-40 °C (without derating), -15-50 °C, -15-50 °C, 40-50 °C (with derating factor), -15-40 °C (without derating), -15-40 °C (without derating)
    • Ambient Air Temperature For Storage : -40-70 °C, -40-70 °C
    • Ambient Air Transport Temperature : -40-70 °C, -40-70 °C
    • Ip Degree Of Protection : IP55, IP55IEC 60529, IP55IEC 61800-5-1
    • Operating Altitude : <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating1000...4800 m with current derating 1 % per 100 m, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 13040.376490870298
    • Circularity Profile : ENVEOLI1506001EN
    • Environmental Disclosure : ENVPEP1506001EN
    • Eu Rohs Directive : Compliant By Exemption
    • Nema Degree Of Protection : NEMA 12
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % without condensation IEC 60068-2-3
    • Pep Code : ENVPEP1506001EN
    • Pep Verification Date : 2026-05-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : variable speed drive
    • Range Of Product : Altivar Process ATV600
  • ETIM
    • ETIM 8 : EC001857
    • ETIM 9 : EC001857
  • Output Attributes
    • Analogue Output Type : software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 10 bits, software-configurable current DQ-, DQ+ 30 V DC, software-configurable current DQ-, DQ+ 100 mA
    • Continuous Output Current : 72 A 4 kHz heavy duty, 87 A 4 kHz normal duty
    • Discrete Output Type : relay outputs R2A, R2C 30 V DC 5000 mA, relay outputs R3A, R3C 30 V DC 5000 mArelay outputs R1A, R1B, R1C 250 V AC 3000 mA, relay outputs R1A, R1B, R1C 30 V DC 3000 mA, relay outputs R2A, R2C 250 V AC 5000 mA, relay outputs R3A, R3C 250 V AC 5000 mA
    • Output Voltage : <= power supply voltage, <= power supply voltage
    • Relay Output Type : configurable relay logic R2 sequence relay NO 100000 cycles, configurable relay logic R3 sequence relay NO 100000 cycles, configurable relay logic R1 fault relay NO/NC 100000 cycles
    • Analogue Output Number : 2
    • Discrete Output Number : 0
    • Maximum Output Frequency : 500 kHz
    • Maximum Output Voltage : 480.0 V
    • Nominal Output Current : 88.0 A
    • Nominal Output Power : 45.0 kW
    • Relay Output Number : 3
    • Speed Drive Output Frequency : 0.1-500 Hz
  • Surge Protection And Filtering Attributes
    • Emc Filter : integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
  • Input Attributes
    • Analogue Input Type : AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits, AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
    • Discrete Input Logic : positive logic (source) DI1...DI8), < 5 V, > 11 V, negative logic (sink) DI1...DI8), > 16 V, < 10 V, 16 preset speeds
    • Input Compatibility : DI5, DI6 discrete input level 1 PLC IEC 65A-68, STOA, STOB discrete input level 1 PLC IEC 61131-2, DI1...DI6 discrete input level 1 PLC IEC 61131-2
    • Analogue Input Number : 3
    • Discrete Input Number : 8
    • Discrete Input Type : DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
    • Number Of Input Phases : 3
  • Specifications
    • Country of Origin : China
    • Depth : 340 mm
  • Batteries & Runtime Attributes
    • Removable Battery : Yes