Variable Speed Drive, Altivar Process ATV600, ATV630, 18.5kW, 25hp, 200 to 240V, IP21, UL type 1

Variable Speed Drive, Altivar Process ATV600, ATV630, 18.5kW, 25hp, 200 to 240V, IP21, UL type 1

SQDATV630D18M3 ATV630D18M3 3606480701498
6612.05 / EA
http://schema.org/OutOfStock
  • Connection Type: RJ45 On The Remote Graphic Terminal)Ethernet/Modbus TCP, RJ45 On The Remote Graphic Terminal)Modbus Serial
  • IsSustainable: Yes
This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 200V to 240V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 18.5kW / 25hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 15kW / 20hp for applications requiring significant overload (up to 150%). It weighs 14.2kg and its dimensions are, 226mm wide, 673mm high, 271mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Modules : VW3A3203, VW3A3204, VW3A3720
  • Conformance Attributes
    • Standards : UL 508C, IEC 61800-3, environment 1 category C2 IEC 61800-3, environment 2 category C3 IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1
  • Complementary Attributes
    • Maximum Horse Power Rating : 25 hp normal duty, 20 hp heavy duty
    • Maximum Switching Current : relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC, relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
    • Maximum THDI : <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12
    • Maximum Transient Current : 86.2 A 60 s normal duty), 95.1 A 60 s heavy duty)
    • UE Rated Operational Voltage : 200...240 V 18.5 kW 25 hp normal duty, 200...240 V 15 kW 20 hp heavy duty
    • Brake Chopper Integrated : false
    • Maximum Associated Fuse Rating : 125.0 A
    • Maximum Input Current Per Phase : 66.7 A
    • Maximum Output Voltage : 240.0 V
    • Minimum Switching Current : relay output R1, R2, R3 5 mA 24 V DC
    • US Rated Supply Voltage : 200...240 V - 15...10 %
    • Maximum Acceleration Under Shock Impact During Operation : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Storage : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Transport : 150 m/s² at 11 ms
    • Maximum Acceleration Under Vibrational Stress During Operation : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Storage : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Transport : 10 m/s² at 13...200 Hz
    • Maximum Deflection Under Vibratory Load During Operation : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Storage : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Transport : 1.5 mm at 2...13 Hz
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8, SI
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
    • Apparent Power : 22.7 kVA 240 V normal duty), 18.7 kVA 240 V heavy duty)
    • Asynchronous Motor Control Profile : constant torque standard, optimized torque mode, variable torque standard
    • Connector Type : RJ45 on the remote graphic terminal)Ethernet/Modbus TCP, RJ45 on the remote graphic terminal)Modbus serial
    • Discrete And Process Manufacturing : building - HVAC compressor centrifugal, food and beverage processing other application, mining mineral and metal fan, mining mineral and metal pump, oil and gas fan, water and waste water other application, building - HVAC screw compressor, food and beverage processing pump, food and beverage processing fan, food and beverage processing atomization, oil and gas electro submersible pump (ESP), oil and gas water injection pump, oil and gas jet fuel pump, oil and gas compressor for refinery, water and waste water centrifuge pump, water and waste water positive displacement pump, water and waste water electro submersible pump (ESP), water and waste water screw pump, water and waste water lobe compressor, water and waste water screw compressor, water and waste water compressor centrifugal, water and waste water fan, water and waste water conveyor, water and waste water mixer
    • Electrical Connection : control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16, line side screw terminal 35...50 mm² AWG 3...AWG 1, motor screw terminal 35...50 mm² AWG 3...AWG 1
    • Electromagnetic Compatibility : electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    • Frequency Resolution : display unit 0.1 Hz, analog input 0.012/50 Hz
    • Insulation Resistance : > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth
    • Line Current : 66.7 A 200 V normal duty), 54.5 A 240 V normal duty), 53.1 A 200 V heavy duty), 44.9 A 240 V heavy duty)
    • Linearity Error : AI1, AI2, AI3 +/- 0.15 % of maximum value analog input, AO1, AO2 +/- 0.2 % analog output
    • Local Signalling : 3 LEDs for local diagnostic, 3 LEDs (dual colour) for embedded communication status, 4 LEDs (dual colour) for communication module status, 1 LED (red) for presence of voltage
    • Motor Power KW : 18.5 kW normal duty), 15 kW heavy duty)
    • Motor Slip Compensation : adjustable, can be suppressed, not available in permanent magnet motor law, automatic whatever the load
    • Option Card : slot A communication module, Profibus DP V1, slot A communication module, PROFINET, slot A communication module, DeviceNet, slot A communication module, Modbus TCP/EtherNet/IP, slot A communication module, CANopen daisy chain RJ45, slot A communication module, CANopen SUB-D 9, slot A communication module, CANopen screw terminals, slot A/slot B digital and analog I/O extension module, slot A/slot B output relay extension module, slot A communication module, Ethernet IP/Modbus TCP/MD-Link, communication module, BACnet MS/TP, communication module, Ethernet Powerlink
    • Permissible Temporary Current Boost : 1.1 x In 60 s normal duty), 1.5 x In 60 s heavy duty)
    • Power Dissipation In W : natural convection 97 W 200 V 4 kHz, forced convection 595 W 200 V 4 kHz
    • Protection Type : thermal protection motor, safe torque off motor, motor phase break motor, thermal protection drive, safe torque off drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, motor phase break drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
    • Sampling Duration : 2 ms +/- 0.5 ms DI1...DI4) - discrete input, 5 ms +/- 1 ms DI5, DI6) - discrete input, 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input, 10 ms +/- 1 ms AO1) - analog output
    • Supply : external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection, internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection, internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection
    • Switching Frequency : 2...12 kHz adjustable, 4...12 kHz with derating factor
    • Synchronous Motor Control Profile : permanent magnet motor, synchronous reluctance motor
    • Vibration Resistance : 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6, 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6
    • Environmental Class During Storage : class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
    • Environmental Class During Transport : class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
    • Carbon Footprint Of The Distribution Phase A4 : 4.5415715068, 5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 7.8261654795, 8 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 5 kg CO2 eq., 4.764729863
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 313 kg CO2 eq., 313.4150136986
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 26 194 kg CO2 eq., 26194.0159255989
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • HTML Description : Variable Speed Drive ATV630Wall MountSupply Frequency: 50...60 Hz - 5...5 %Us Rated Supply Voltage: 200...240 V - 15...10 %26mm W x 673mm H x 271mm D
    • Manufacturer : Schneider Electric
    • Device Type : Variable speed drive - VSD Compacts
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1411001EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : YES_SSI2
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Function Option Id : ADVANCED
    • Function Option : Advanced
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • 1 Phase Low Current Possible : false
    • 4 Quadrant Operation Possible : false
    • Application In Domestic And Commercial Area Permitted : false
    • Base Load Current At High Overload : 63.4 A
    • Base Load Current At Low Overload : 78.4 A
    • Braking To Standstill : by DC injection
    • Capacity Of Dc Link : 4920.0 µF
    • Computer Port : true
    • Design Of Frequency Changer : U converter
    • Device Short Name : ATV630
    • EMC Filter : without EMC filter
    • Enclosure Mounting : wall mounted
    • Exchange Mode : half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
    • Functionality : full
    • Housing Material : plastic
    • Isolation : between power and control terminals
    • Maximum Associated Fuse Rating : 125.0 A
    • Maximum Input Current Per Phase : 66.7 A
    • Method Of Access : slave Modbus TCP
    • Motor Starter Type : variable speed drive
    • Noise Level : 63.5 dB 86/188/EEC
    • Nominal Switching Frequency : 4 kHz
    • Number Of Addresses : 1-247 Modbus serial
    • Operating Element Present : true
    • Optical Interface Present : false
    • Package Weight Lbs : 33.000 kg
    • Power Loss Per Device Current Dependent : 860.0 W
    • Power Loss Static Current Independent : 28.0 W
    • Power Range : 15-25 kW 200-240 V 3 phase
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : variable speed drive
    • Product Specific Application : process and utilities
    • Range Of Product : Altivar Process ATV600
    • Refresh Time : relay output R1, R2, R3)5 ms +/- 0.5 ms)
    • Relative Symmetric Mains Voltage Tolerance : 10 %
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • Returnability : Yes
    • Safety Function : STO (safe torque off) SIL 3
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27
    • Specific Application : utility
    • Supply Frequency : 50...60 Hz - 5...5 %
    • Supporting Protocol For As Interface Safety At Work : false
    • Supporting Protocol For Asi : false
    • Supporting Protocol For Bacnet : false
    • Supporting Protocol For Can : true
    • Supporting Protocol For Data Highway : false
    • Supporting Protocol For Devicenet : false
    • Supporting Protocol For Devicenet Safety : false
    • Supporting Protocol For Ethernet Ip : true
    • Supporting Protocol For Foundation Fieldbus : false
    • Supporting Protocol For Interbus : false
    • Supporting Protocol For Knx : false
    • Supporting Protocol For Lon : false
    • Supporting Protocol For Modbus : true
    • Supporting Protocol For Other Bus Systems : false
    • Supporting Protocol For Profibus : true
    • Supporting Protocol For Profinet Cba : true
    • Supporting Protocol For Profinet Io : true
    • Supporting Protocol For Profisafe : false
    • Supporting Protocol For Safetybus P : false
    • Supporting Protocol For Sercos : false
    • Supporting Protocol For Suconet : false
    • Supporting Protocol For TCP IP : true
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 26 525 kg CO2 eq.
    • Variant : standard version
    • Volume Of Cooling Air : 240 m3/h
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • EMC Limit Value Complied : false
    • Permitted Relative Humidity During Transport : class 2K5 according to EN 60721-3
    • With Safety Function Safe Brake Management Sbc Sbt : false
    • With Safety Function Safe Direction SDI : false
    • With Safety Function Safe Operating Stop Sos : false
    • With Safety Function Safe Position Sp : false
    • With Safety Function Safe Speed Monitor Ssm : false
    • With Safety Function Safe Stop 1 SS1 : false
    • With Safety Function Safe Torque Off Sto : true
    • With Safety Function Safely Limited Position Slp : false
    • With Safety Function Safely Limited Speed Sls : false
    • With Sft Fct Safe Stop 2 Ss2 : false
    • Relationship Type : Compatible relationship
    • Application In Industrial Area Permitted : true
    • Supporting Protocol For Interbus Safety : false
    • Pep Code : ENVPEP1411001EN
    • Pep Verification Date : 2021-11-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 45 kW electric motors for fluid management and industrial applications in IP21/UL type 1 conditions, at 380V to 480V rated 3-phase voltage supply. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
    • Functional Unit Unit : unité (unit)
    • Product Kit Identifier : N
    • Product Manager : LEONARDO LAZZARO
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -15-50 °C (without derating), -15-50 °C (without derating), 50-60 °C (with derating factor)
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP21IEC 61800-5-1, IP21IEC 60529
    • Operating Altitude : <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, 1000...4800 m with current derating 1 % per 100 m
    • Environmental Class During Operation : class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 26524.5634061469
    • Ambient Air Transport Temperature : -40-70 °C
    • Circularity Profile : ENVEOLI1411001EN
    • Environmental Disclosure : ENVPEP1411001EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % without condensation IEC 60068-2-3
    • Permitted Relative Humidity During Operation : class 3K5 according to EN 60721-3
    • Permitted Relative Humidity During Storage : class 1K5 according to EN 60721-3
    • Pep Code : ENVPEP1411001EN
    • Pep Verification Date : 2021-11-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : variable speed drive
    • Range Of Product : Altivar Process ATV600
  • Output Attributes
    • Analogue Output Type : software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 10 bits, software-configurable current DQ-, DQ+ 30 V DC, software-configurable current DQ-, DQ+ 100 mA
    • Continuous Output Current : 78.4 A 4 kHz normal duty, 63.4 A 4 kHz heavy duty
    • Discrete Output Type : relay outputs R1A, R1B, R1C 250 V AC 3000 mA, relay outputs R1A, R1B, R1C 30 V DC 3000 mA, relay outputs R2A, R2C 250 V AC 5000 mA, relay outputs R2A, R2C 30 V DC 5000 mA, relay outputs R3A, R3C 250 V AC 5000 mA, relay outputs R3A, R3C 30 V DC 5000 mA
    • Relay Output Type : configurable relay logic R1 fault relay NO/NC 100000 cycles, configurable relay logic R2 sequence relay NO 100000 cycles, configurable relay logic R3 sequence relay NO 100000 cycles
    • Maximum Output Voltage : 240.0 V
    • Relay Output Number : 3
    • Speed Drive Output Frequency : 0.1-500 Hz
  • Surge Protection And Filtering Attributes
    • EMC Filter : without EMC filter
  • Input Attributes
    • Analogue Input Type : AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits, AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
    • Discrete Input Logic : positive logic (source) DI1...DI8), < 5 V, > 11 V, negative logic (sink) DI1...DI8), > 16 V, < 10 V
    • Input Compatibility : DI1...DI6 discrete input level 1 PLC IEC 61131-2, DI5, DI6 discrete input level 1 PLC IEC 65A-68, STOA, STOB discrete input level 1 PLC IEC 61131-2
    • Discrete Input Type : DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
    • Number Of Input Phases : 3
  • Batteries & Runtime Attributes
    • Removable Battery : YES