SQUARE D

variable speed drive, Altivar Machine ATV320, 5.5kW, 380 to 500V, 3 phases, enclosed, IP65

variable speed drive, Altivar Machine ATV320, 5.5kW, 380 to 500V, 3 phases, enclosed, IP65

SQDATV320U55N4WS ATV320U55N4WS 3606489548711
2510.70 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Depth: 13.19 in
  • Height: 20.51 in
  • Operating Position: Vertical +/- 10 Degree
  • Width: 12.6 in
Altivar Machine ATV320 range is an offer of variable speed drives designed for Original Equipment Manufacturers (OEMs). This ATV320 drive can feed 3-phase synchronous and asynchronous motors. It works at a rated power up to 5.5kW, and a rated voltage fro
QTY
  • Product Description
  • Features
  • Specifications
Altivar Machine ATV320 range is an offer of variable speed drives designed for Original Equipment Manufacturers (OEMs). This ATV320 drive can feed 3-phase synchronous and asynchronous motors. It works at a rated power up to 5.5kW, and a rated voltage fro
  • Environmental Class During Storage
    • class 1C3 according to EN 60721-3
    • class 1S2 according to EN 60721-3
  • US Rated Supply Voltage
    • 380...500 V - 15...10 %
  • Analogue Input Type
    • AI1 voltage 0...10 V DC 30 kOhm 10 bits
    • AI2 bipolar di
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Analogue Output Type
    • software-configurable current AQ1 0...20 mA 800 Ohm 10 bits
    • software-confi
  • Communication
    • VW3A3608
    • VW3A3616
    • VW3A3627
    • VW3A3618
    • VW3A3628
    • VW3A3601
  • Carbon Footprint Of The Installation Phase A5
    • 0.2 kg CO2 eq.
    • 0.1952141221
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 4.2655877863
    • 4 kg CO2 eq.
  • Discrete Input Type
    • STO safe torque off, 24 V DC1.5 kOhm
    • DI1...DI6 logic inputs, 24 V DC 30 V)
    • DI1...DI6 logic inputs, 24 V DC
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 145 kg CO2 eq.
    • 145.0992366412
  • Method Of Access
    • slave CANopen
  • Line Current
    • 20.7 A 380 V heavy duty)
    • 14.5 A 500 V heavy duty)
  • Motor Slip Compensation
    • automatic whatever the load
    • adjustable 0...300 %
    • not available in voltage/frequency ratio (2 or 5 points)
  • Maximum Switching Current
    • relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC
    • re
  • Relay Output Type
    • configurable relay logic R1A 1 NO 100000 cycles
    • configurable relay logic R1B 1 NC 100000 cycles
    • configurable r
  • Protection Type
    • input phase breaks drive
    • overcurrent between output phases and earth drive
    • overheating protection drive
    • short-circuit between motor phases drive
    • short
  • Sampling Duration
    • 2 ms AI1, AI2, AI3) - analog input
    • 2 ms AQ1) - analog output
  • Linearity Error
    • AI1, AI2, AI3 +/- 0.2...0.5 % of maximum value analog input
    • AQ1 +/- 0.3 % analog output
    • AQ1 +/- 0.3 % anal
  • Environmental Class During Operation
    • class 3C3 according to IEC 60721-3-3
    • class 3S2 according to IEC 60721-3-3
  • Option Card
    • communication module, CANopen
    • communication module, EtherCAT
    • communication module, Profibus DP V1
    • communication module, PROFINET
    • communication module, PROFI
  • Persona Type Names
    • End User
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
  • Motor Power KW
    • 5.5 kW heavy duty
  • Refresh Time
    • logic input DI1...DI4)8 ms
    • relay output R1A, R1B, R1C)2 ms
    • relay output R2A, R2C)2 ms
    • relay output R2A, R2C)2
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 5 884 kg CO2 eq.
    • 5884.0114396576
  • Electromagnetic Compatibility
    • electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    • radiated radio-frequency electro
  • Apparent Power
    • 12.6 kVA 500 V heavy duty)
  • Persona Type Ids
    • EU
    • OM
    • OM8
  • Environmental Class During Transport
    • class 2C3 according to EN 60721-3
    • class 2S1 according to EN 60721-3
  • Carbon Footprint Of The Distribution Phase A4
    • 3.4836183206
    • 3 kg CO2 eq.
  • Minimum Switching Current
    • relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC
  • Asynchronous Motor Control Profile
    • voltage/frequency ratio, 5 points
    • flux vector control without sensor, standard
    • voltage/frequency ratio - Energy Saving, quadratic U/f
    • flux vector control without sensor - Energy Saving
    • voltage/frequency ratio, 2 points
  • Transient Overtorque
    • 170-200 % of nominal motor torque
  • Discrete Output Type
    • open collector DQ+ 0-1 kHz 30 V DC 100 mA
    • op
  • Power Dissipation In W
    • self-cooled 195.0 W 380 V 4 kHz
  • Ambient Air Temperature For Operation
    • -10-40 °C without derating
    • 40-60 °C with derating factor
  • Speed Accuracy
    • +/- 10 % of nominal slip 0.2 Tn to Tn
  • Switching Frequency
    • 2...16 kHz adjustable
    • 4...16 kHz with derating factor
  • Assets
    • CAD : https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0000951_3D-CAD
  • Complementary Attributes
    • Brake Chopper Integrated : true
    • Maximum Associated Fuse Rating : 40 A
    • Maximum Horse Power Rating : 7.5 hp
    • Maximum Input Current Per Phase : 20.7 A
    • Maximum Output Voltage : 500 V
    • Maximum Acceleration Under Shock Impact During Operation : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Storage : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Transport : 150 m/s² at 11 ms
    • Maximum Acceleration Under Vibrational Stress During Operation : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Storage : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Transport : 10 m/s² at 13...200 Hz
    • Maximum Deflection Under Vibratory Load During Operation : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Storage : 3.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Transport : 3.5 mm at 2...13 Hz
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Device Type : Variable speed drive - VSD Compacts
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Manufacturing Carbon Footprint : 145.0992366412
    • Distribution Carbon Footprint : 3.4836183206
    • Installation Carbon Footprint : 0.1952141221
    • Use Carbon Footprint : 5884.0114396576
    • End Of Life Carbon Footprint : 4.2655877863
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1908005EN
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Conformity Date : 1816
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • China ROHS Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : YES_SSI2
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • 1 Phase Low Current Possible : false
    • 4 Quadrant Operation Possible : true
    • Application In Domestic And Commercial Area Permitted : false
    • Base Load Current At High Overload : 14.3 A
    • Braking To Standstill : by DC injection
    • Capacity Of Dc Link : 780 µF
    • Computer Port : true
    • Design Of Frequency Changer : U converter
    • Encoder Protocol : RS 422
    • Format Of The Drive : enclosed
    • Housing Material : sheet steel
    • Maximum Associated Fuse Rating : 40 A
    • Maximum Input Current Per Phase : 20.7 A
    • Nominal Switching Frequency : 4 kHz
    • Number Of Hw Interfaces Industrial Ethernet : 0.0
    • Number Of Hw Interfaces Other : 1.0
    • Number Of Hw Interfaces Parallel : 0.0
    • Number Of Hw Interfaces Profinet : 0.0
    • Number Of Hw Interfaces Serial Rs232 : 0.0
    • Number Of Hw Interfaces Serial Rs422 : 0.0
    • Number Of Hw Interfaces Serial Rs485 : 1.0
    • Number Of Hw Interfaces Serial Tty : 0.0
    • Number Of Hw Interfaces Usb : 0.0
    • Number Of Output Phases : 3
    • Operating Element Present : true
    • Optical Interface Present : false
    • Package Weight Lbs : 36.000 kg
    • Power Loss Per Device Current Dependent : 195.0 W
    • Power Loss Static Current Independent : 195.0 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : variable speed drive
    • Product Specific Application : complex machines
    • Range Of Product : Altivar Machine ATV320
    • Relative Symmetric Mains Voltage Tolerance : 10 %
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • Returnability : Yes
    • Supporting Protocol For As Interface Safety At Work : false
    • Supporting Protocol For Asi : false
    • Supporting Protocol For Bacnet : false
    • Supporting Protocol For Can : true
    • Supporting Protocol For Data Highway : false
    • Supporting Protocol For Devicenet : true
    • Supporting Protocol For Devicenet Safety : false
    • Supporting Protocol For Ethernet Ip : true
    • Supporting Protocol For Foundation Fieldbus : false
    • Supporting Protocol For Interbus : false
    • Supporting Protocol For Knx : false
    • Supporting Protocol For Lon : false
    • Supporting Protocol For Modbus : true
    • Supporting Protocol For Other Bus Systems : true
    • Supporting Protocol For Profibus : true
    • Supporting Protocol For Profinet Cba : false
    • Supporting Protocol For Profinet Io : true
    • Supporting Protocol For Profisafe : false
    • Supporting Protocol For Safetybus P : false
    • Supporting Protocol For Sercos : false
    • Supporting Protocol For Suconet : false
    • Supporting Protocol For TCP IP : true
    • Sustainable Packaging : Yes
    • Synchronous Motor Control Profile : vector control without sensor
    • Total Lifecycle Carbon Footprint : 6 037 kg CO2 eq.
    • Variant : with disconnect switch
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • EMC Limit Value Complied : true
    • Number Of Inputs Bidirectional Not Potential Free : 0
    • Number Of Inputs Potential Free : 0
    • Permitted Relative Humidity During Transport : class 2K5 according to EN 60721-3
    • With Safety Function Safe Brake Management Sbc Sbt : false
    • With Safety Function Safe Direction SDI : false
    • With Safety Function Safe Operating Stop Sos : false
    • With Safety Function Safe Position Sp : false
    • With Safety Function Safe Speed Monitor Ssm : false
    • With Safety Function Safe Stop 1 SS1 : true
    • With Safety Function Safe Torque Off Sto : true
    • With Safety Function Safely Limited Position Slp : false
    • With Safety Function Safely Limited Speed Sls : true
    • With Sft Fct Safe Stop 2 Ss2 : false
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 6037.0550965278
    • Relationship Type : Compatible relationship
    • Accessories : VW3A95817
    • Application In Industrial Area Permitted : true
    • Supporting Protocol For Interbus Safety : false
    • Pep Code : ENVPEP1908005EN
    • Pep Verification Date : 2020-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 27000
    • Functional Unit Description : To control the speed and torque of an synchronous electric motor for general application during 10 years and a 46% use rate, in accordance with the relevant standards. IP degree of protection:IP65 conforming to EN/IEC 61800-5-1 rated supply voltage
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 9965.901
    • Energy Model Manufacturing A1 A3 : Energy model used: Indonesia
    • Energy Model Installation A5 : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model Use B6 : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 : Electricity Mix; AC; < 1kV; EU-27
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.0064878711
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.006219584
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000001394
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.0000000073
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0002680408
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000997
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 62003.3604811086
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 1307.4389312977
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 48.9421374046
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 2.5307862595
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 60612.231030727
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 32.2175954198
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.0113027565
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.0009716496
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.0103311069
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 75.2681775253
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 45.6526717557
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0000095863
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 29.6154961832
    • Materials For Energy Recovery Kg Total Life Cycle : 0.2087863002
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0.0000000407
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0.2087862595
    • Materials For Recycling Kg Total Life Cycle : 27.7146755725
    • Materials For Recycling Kg Manufacturing A1 A3 : 2.3795038168
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 3.5888358779
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 21.7463358779
    • Net Use Of Fresh Water M3 Total Life Cycle : 16.3474009462
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.9957744275
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0003117676
    • Net Use Of Fresh Water M3 Installation A5 : 0.0000213372
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 15.3469844406
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.0043089733
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 22223.0276330557
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 213.2896946565
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.1237671756
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0264981298
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 22009.4614017198
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.126271374
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.001449575
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000199676
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.0000000071
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.0000000004
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0014293776
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000002223
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 18.0876947516
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.1463358779
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.000088154
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000052111
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 17.9410581034
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0002074053
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 113648.1800491934
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 2878.179389313
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 49.1904961832
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 2.5455229008
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 110676.1487629338
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 42.1158778626
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 122258.0221963075
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 2960.0038167939
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 49.2554198473
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 2.5494389313
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 119204.0543604297
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 42.1591603053
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 8611.4462492165
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 81.8048473282
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0656419466
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0039595191
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 8529.5284149264
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0433854962
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 47.1520992366
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 47.1520992366
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 113600.9815759109
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 2830.9809160305
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 49.1904961832
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 2.5455229008
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 110676.1487629338
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 42.1158778626
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 11.7728244275
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 11.7728244275
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 8599.673424789
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 70.0320229008
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0656419466
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0039595191
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 8529.5284149264
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0433854962
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 13.5834732824
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 13.5834732824
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 270963.7497469212
    • Air Pollution M3 Manufacturing A1 A3 : 18171.4122137405
    • Air Pollution M3 Distribution A4 : 148.1908396947
    • Air Pollution M3 Installation A5 : 7.785480916
    • Air Pollution M3 Operational Energy Use B6 : 252348.1104492113
    • Air Pollution M3 End Of Life C1 C4 : 288.2507633588
    • Water Pollution M3 Total Life Cycle : 259780.1406764848
    • Water Pollution M3 Manufacturing A1 A3 : 10446.5267175573
    • Water Pollution M3 Distribution A4 : 572.8740458015
    • Water Pollution M3 Installation A5 : 29.6051908397
    • Water Pollution M3 Operational Energy Use B6 : 246895.4438825917
    • Water Pollution M3 End Of Life C1 C4 : 1835.6908396947
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 45.5743344563
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 2.1690530752
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 1.7673996727
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 1.0536183206
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.0159052672
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.0008134008
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 44.496031128
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.0079663397
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 6037.0550965278
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 145.0992366412
    • Global Warming Kg Equivalent Co2 Distribution A4 : 3.4836183206
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.1952141221
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 5884.0114396576
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 4.2655877863
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.0639106489
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.0011350305
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0.0000607933
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 2.1030902491
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.0008563534
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.0934467939
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.0036635496
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0.0001976771
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 1.6679317551
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.0021598969
  • General Attributes
    • Product Or Component Type : variable speed drive
    • Range Of Product : Altivar Machine ATV320
  • Output Attributes
    • Maximum Output Voltage : 500 V
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=484224144&lang=en-us
    • Take Back : No
    • China ROHS Regulation : X
    • Carbon Footprint : 6037.0550965278
    • Ambient Air Transport Temperature : -25-70 °C
    • Circularity Profile : ENVEOLI1908005EN
    • Environmental Disclosure : ENVPEP1908005EN
    • EU ROHS Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Permitted Relative Humidity During Operation : class 3K5 according to EN 60721-3
    • Permitted Relative Humidity During Storage : class 1K5 according to EN 60721-3
    • Pep Code : ENVPEP1908005EN
    • Pep Verification Date : 2020-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • Input Attributes
    • Number Of Input Phases : 3
  • Specifications
    • Country of Origin : Indonesia