variable speed drive, Altivar Machine ATV340, 0.75kW, heavy duty, 400V, 3 phases

variable speed drive, Altivar Machine ATV340, 0.75kW, heavy duty, 400V, 3 phases

SQDATV340U07N4 ATV340U07N4 3606480966873
951.03 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 0.75kW / 1hp and a rated voltage f
QTY
  • Product Description
  • Features
  • Specifications
This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 0.75kW / 1hp and a rated voltage f
  • Insulation Resistance
    • > 1 MOhm 500 V DC for 1 minute to earth
  • Environmental Class During Storage
    • class 1C3 according to EN 60721-3-1
    • class 1S2 according to EN 60721-3-1
  • Power Range
    • 0.55-1 kW 380-440 V 3 phase
    • 0.55-1 kW 480-500 V 3 phase
  • Connector Type
    • 1 x RJ45, Modbus serial on front face
    • 1 x RJ45, Modbus serial HMI on front face
    • 1 x RJ45, Modbus s
  • US Rated Supply Voltage
    • 380...480 V - 15...10 %
  • Input Output Type
    • programmable as logic input/output DQ1 0-1 kHz, <= 30 V DC, 100 mA
    • programmable as logic input/output DQ1 0-1 kHz, <= 30
  • Analogue Input Type
    • AI1 software-configurable current 0...20 mA 250 Ohm 12 bits
    • AI1 software-c
  • Continuous Output Current
    • 2.2 A 4 kHz heavy duty
    • 2.8 A 4 kHz normal duty
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Analogue Output Type
    • software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits
    • softwa
  • Communication
    • VW3A3607
    • VW3A3609
    • VW3A3601
  • Carbon Footprint Of The Installation Phase A5
    • 0.6 kg CO2 eq.
    • 0.6486902542592797
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 4.226225434014892
    • 4 kg CO2 eq.
  • Encoder Protocol
    • 1 Vpp
    • EnDat 2.2
    • resolver
    • RS 422
    • SSI 24V
    • SSI 5V
    • TTL/HTL
  • Discrete Input Type
    • PTI programmable as pulse input 0-30 kHz, 24 V DC 30 V)
    • PTI programmable as pulse inpu
  • Electrical Connection
    • screw terminal 1.5...4 mm² line side
    • screw terminal 4...6 mm² DC bus
    • screw terminal 1.5...4 mm² motor
    • screw terminal
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 65 kg CO2 eq.
    • 65.48024960432647
  • Method Of Access
    • slave Modbus RTU
  • Line Current
    • 2.6 A 380 V normal duty)
    • 2.1 A 480 V normal duty)
    • 3.4 A 380 V heavy duty)
    • 2.6 A 480 V heavy duty)
    • 2.6 A 48
  • Motor Slip Compensation
    • can be suppressed
    • not available in permanent magnet motor law
    • automatic whatever the load
    • adjustable
  • Maximum Switching Current
    • relay output R1C resistive, cos phi = 1 3 A 250 V AC
    • relay output R1C resistive, cos phi = 1 3
  • Relay Output Type
    • relay outputs R1A
    • relay outputs R1C 100000 cycles
    • relay outputs R2A
    • relay outputs R2C 100000 cycles
    • relay outputs R2C 1000
  • Input Compatibility
    • DI1...DI5 discrete input level 1 PLC IEC 61131-2
    • PTI pulse input level 1 PLC IEC 65A-68
    • PTI pulse input lev
  • Protection Type
    • thermal protection motor
    • safe torque off motor
    • motor phase loss motor
    • thermal protection drive
    • safe torque off drive
    • overheating drive
    • ov
  • Sampling Duration
    • 2 ms +/- 0.5 ms DI1...DI5) - discrete input
    • 5 ms +/- 1 ms PTI) - pulse input
    • 5 ms +/- 1 m
  • Linearity Error
    • AI1, AI2 +/- 0.15 % of maximum value analog input
    • AQ1 +/- 0.2 % analog output
  • Environmental Class During Operation
    • class 3C3 according to IEC 60721-3-3
    • class 3S3 according to IEC 60721-3-3
  • Maximum Horse Power Rating
    • 1.5 hp normal duty
    • 1 hp heavy duty
  • Vibration Resistance
    • 1.5 mm peak to peak 2-19 Hz)IEC 60721-3-3 class 3M3
    • 1 gn 9-200 Hz)IEC 60721-3-3 class 3M3
    • 1 gn 9-2
  • Option Card
    • communication module, Profibus DP V1
    • communication module, PROFINET
    • communication module, DeviceNet
    • communication module, CANopen
    • communication module, CA
  • Persona Type Names
    • End User
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • System Integrator
  • Motor Power KW
    • 1.1 kW normal duty
    • 0.75 kW heavy duty
  • Refresh Time
    • relay output R1, R2)5 ms +/- 0.5 ms)
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 1 264 kg CO2 eq.
    • 1263.8326001965108
  • Electromagnetic Compatibility
    • electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    • radiated radio-frequency electro
  • Supply Frequency
    • 50...60 Hz +/- 5 %
  • Apparent Power
    • 2.2 kVA 480 V normal duty)
    • 2.2 kVA 480 V heavy duty)
  • Persona Type Ids
    • EU
    • OM
    • OM8
    • SI
  • Environmental Class During Transport
    • class 2C3 according to EN 60721-3-2
    • class 2S1 according to EN 60721-3-2
  • Carbon Footprint Of The Distribution Phase A4
    • 0.4739159791096693
    • 0.5 kg CO2 eq.
  • Synchronous Motor Control Profile
    • permanent magnet motor
    • reluctance motor
  • Minimum Switching Current
    • relay output R1B 5 mA 24 V DC
    • relay output R2C 5 mA 24 V DC
    • relay output R
  • Operating Altitude
    • <= 9842.52 ft (3000 m) with current derating above 1000m
  • Safety Function
    • STO (safe torque off) SIL 3
  • Discrete Input Logic
    • positive logic (source) DI1...DI5), < 5 V, > 11 V
    • negative logic (sink) DI1...DI5), > 16 V, < 10 V
    • negat
  • Asynchronous Motor Control Profile
    • constant torque standard
    • variable torque standard
    • optimized torque mode
  • Discrete Output Type
    • programmable output DQ1, DQ2 30 V DC 100 mA
  • Shock Resistance
    • 15 gn 11 ms, class 3M3 IEC 60721-3-3
  • Maximum Transient Current
    • 3.1 A 60 s normal duty)
    • 3.3 A 60 s heavy duty)
    • 3.8 A 2 s normal duty)
    • 4 A 2 s heavy duty)
    • 4 A
  • Discrete And Process Manufacturing
    • hoisting tower crane
    • hoisting other application
    • material handling grouping conveyor
    • material handling palletizer - high performance
    • material handling palletizer - high pe
  • Power Dissipation In W
    • natural convection 28 W 380 V 4 kHz heavy duty)
    • forced convect
  • Ambient Air Temperature For Operation
    • -15-50 °C without derating vertical position)
    • 50-60 °C with derating factor vertical position)
    • 50-60 °C with dera
  • UE Rated Operational Voltage
    • 380...480 V 1.1 kW normal duty
    • 380...480 V 0.75 kW heavy duty
    • 380...480 V 1.5 hp normal duty
    • 380...
  • Switching Frequency
    • 2...16 kHz adjustable
    • 14...16 kHz with derating factor
  • Assets
    • CAD : https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0000956_3D-CAD
  • Complementary Attributes
    • Brake Chopper Integrated : true
    • Maximum Associated Fuse Rating : 8.0 A
    • Maximum Input Current Per Phase : 3.4 A
    • Maximum Output Voltage : 480 V
    • Maximum Acceleration Under Shock Impact During Operation : 70 m/s² at 22 ms
    • Maximum Acceleration Under Shock Load During Storage : 70 m/s² at 22 ms
    • Maximum Acceleration Under Shock Load During Transport : 70 m/s² at 22 ms
    • Maximum Acceleration Under Vibrational Stress During Operation : 5 m/s² at 9...200 Hz
    • Maximum Acceleration Under Vibratory Load During Storage : 5 m/s² at 9...200 Hz
    • Maximum Acceleration Under Vibratory Load During Transport : 5 m/s² at 9...200 Hz
    • Maximum Deflection Under Vibratory Load During Operation : 1.5 mm at 2...9 Hz
    • Maximum Deflection Under Vibratory Load During Storage : 1.5 mm at 2...9 Hz
    • Maximum Deflection Under Vibratory Load During Transport : 1.5 mm at 2...9 Hz
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-10-02
    • Device Type : Variable speed drive - VSD Compacts
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Manufacturing Carbon Footprint : 65.4802496043265
    • Distribution Carbon Footprint : 0.473915979109669
    • Installation Carbon Footprint : 0.64869025425928
    • Use Carbon Footprint : 1263.83260019651
    • End Of Life Carbon Footprint : 4.22622543401489
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2311030EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Conformity Date : 1923
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • China ROHS Label : 5
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : YES_SSI2
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • 1 Phase Low Current Possible : false
    • 4 Quadrant Operation Possible : true
    • Application In Domestic And Commercial Area Permitted : false
    • Assembly Style : with heat sink
    • Base Load Current At High Overload : 2.2 A
    • Base Load Current At Low Overload : 2.8 A
    • Braking To Standstill : by DC injection
    • Capacity Of Dc Link : 195.0 µF
    • Computer Port : true
    • Design Of Frequency Changer : U converter
    • Housing Material : plastic
    • Isolation : between power and control terminals
    • Maximum Associated Fuse Rating : 8.0 A
    • Maximum Input Current Per Phase : 3.4 A
    • Motor Starter Type : variable speed drive
    • Nominal Switching Frequency : 4 kHz
    • Number Of Hw Interfaces Industrial Ethernet : 0
    • Number Of Hw Interfaces Other : 0
    • Number Of Hw Interfaces Parallel : 0
    • Number Of Hw Interfaces Profinet : 0
    • Number Of Hw Interfaces Serial Rs232 : 0
    • Number Of Hw Interfaces Serial Rs422 : 0
    • Number Of Hw Interfaces Serial Rs485 : 1
    • Number Of Hw Interfaces Serial Tty : 0
    • Number Of Hw Interfaces Usb : 0
    • Number Of Output Phases : 3
    • Operating Element Present : true
    • Optical Interface Present : false
    • Package Weight Lbs : 2.432 kg
    • Power Loss Per Device Current Dependent : 49.0 W
    • Power Loss Static Current Independent : 16.0 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : variable speed drive
    • Product Specific Application : machine
    • Range Of Product : Altivar Machine ATV340
    • Relative Symmetric Mains Voltage Tolerance : 10 %
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • Returnability : Yes
    • Specific Application : machine
    • Supporting Protocol For As Interface Safety At Work : false
    • Supporting Protocol For Asi : false
    • Supporting Protocol For Bacnet : false
    • Supporting Protocol For Can : true
    • Supporting Protocol For Data Highway : false
    • Supporting Protocol For Devicenet : false
    • Supporting Protocol For Devicenet Safety : false
    • Supporting Protocol For Ethernet Ip : false
    • Supporting Protocol For Foundation Fieldbus : false
    • Supporting Protocol For Interbus : false
    • Supporting Protocol For Knx : false
    • Supporting Protocol For Lon : false
    • Supporting Protocol For Modbus : true
    • Supporting Protocol For Other Bus Systems : true
    • Supporting Protocol For Profibus : true
    • Supporting Protocol For Profinet Cba : true
    • Supporting Protocol For Profinet Io : true
    • Supporting Protocol For Profisafe : false
    • Supporting Protocol For Safetybus P : false
    • Supporting Protocol For Sercos : false
    • Supporting Protocol For Suconet : false
    • Supporting Protocol For TCP IP : false
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 1 335 kg CO2 eq.
    • Variant : standard version
    • Volume Of Cooling Air : 18.0 m3/h
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • EMC Limit Value Complied : true
    • Number Of Inputs Bidirectional Not Potential Free : 0
    • Number Of Inputs Potential Free : 0
    • Permitted Relative Humidity During Transport : class 2K5 according to EN 60721-3
    • With Safety Function Safe Brake Management Sbc Sbt : true
    • With Safety Function Safe Direction SDI : false
    • With Safety Function Safe Operating Stop Sos : false
    • With Safety Function Safe Position Sp : false
    • With Safety Function Safe Speed Monitor Ssm : false
    • With Safety Function Safe Stop 1 SS1 : true
    • With Safety Function Safe Torque Off Sto : true
    • With Safety Function Safely Limited Position Slp : false
    • With Safety Function Safely Limited Speed Sls : true
    • With Sft Fct Safe Stop 2 Ss2 : false
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 1334.661681468221
    • Relationship Type : Compatible relationship
    • Application In Industrial Area Permitted : true
    • Supporting Protocol For Interbus Safety : false
    • Pep Code : ENVPEP2311030EN
    • Pep Verification Date : 2024-10-01
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Product Weight In G : 2432
    • Functional Unit Description : To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine's operating point for 4 kW for heavy duty electric motors for fluid management and industrial applications in IP20/UL type 1 conditions, at 380V to 480V ra
    • Functional Unit Quantity : 1
    • Functional Unit Unit : Unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 3083.52
    • Energy Model Manufacturing A1 A3 : Indonesia, ID
    • Energy Model Installation A5 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model Use B6 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model End Of Life C1 C4 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Recyclability Potential In : 47
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 7.702394219500835
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.47764561584224585
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.002998573126642449
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.0018809693279947526
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 7.21169102828759
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.008178032916362002
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.026689818156404057
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Biogenic Carbon Content Of The Product Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Product Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Product Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 2.1313290842275614
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : 0.39845166876876875
    • Climate Change Biogenics Kg Co2 Eq Distribution A4 : 0
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.030436529182139252
    • Climate Change Biogenics Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Biogenics Kg Co2 Eq Repair B3 : 0
    • Climate Change Biogenics Kg Co2 Eq Replacement B4 : 0
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 1.6859298003674201
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.016511085909233243
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.15807464799751691
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 1332.5297801826684
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 65.08122611225377
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 0.4739159791096693
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.6182536720556282
    • Climate Change Fossil Fuels Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Repair B3 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Replacement B4 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 1262.1466703961435
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 4.209714023106117
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -4.985778994065083
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 1334.661681468221
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 65.48024960432647
    • Climate Change Total Kg Co2 Eq Distribution A4 : 0.4739159791096693
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.6486902542592797
    • Climate Change Total Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Total Kg Co2 Eq Repair B3 : 0
    • Climate Change Total Kg Co2 Eq Replacement B4 : 0
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 1263.8326001965108
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 4.226225434014892
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -5.144416052766797
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.010427630225941195
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.010334683499661277
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.00000001863934020442
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.00000001663970238577
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.00009155320275004216
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.00000135824448728563
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Benefits Loads Beyond System Boundaries D : -0.00011616834192277621
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 33341.097279658854
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 1092.9195592674116
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 6.605051739305288
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 6.355816012558516
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 32198.69656194703
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 36.52029069254761
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -89.04090081755642
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 15488.046973283444
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 1426.4371614102809
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 0.3189350773533455
    • Ecotoxicity Fresh Water Ctue Installation A5 : 7.3589777870321536
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 13610.510460765803
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 443.42143824297534
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -268.1805256254856
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.00005880387108904286
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.00000275659615049946
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.0000000243851887327
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0.00000001134798105713
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.00005595139947346688
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.0000000601422952867
    • Emission Of Fine Particles Incidence Of Diseases Benefits Loads Beyond System Boundaries D : -0.00000039082906509277
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.027130391736193995
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.0005548945244718351
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.026193209088174886
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0.00038228812354727603
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.004098009624099696
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.0005584145013628277
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.00000017760015341153
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.00001479620779597344
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.003460233541261181
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.00006438777352630256
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.00002111754701899861
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 150.77205498831378
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 149.7962551730045
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.015990243699643174
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.9598095716096506
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -9.450404352289937
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.00000367503809468566
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000203055328771014
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0.0000000000083203572
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0.00000007246780454744
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000014738157731028
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000142462710476061
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000135182742718297
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.00000799274550675884
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000203333396417017
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0.00000000090040319012
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0.0000000026740785814
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000584597292596196
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.0000001098641348552
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000006741223508164
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 27.6594908494879
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 1.8833171981348547
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0
    • Impacts Related To Land Use Soil Quality Installation A5 : 0.022714838134704464
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 25.146556173210115
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.6069026400082244
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : -1.569282899242874
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 2788.4112841051733
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 895.2463628519845
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.001153220688387212
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.09874736856767691
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 1879.1272980642837
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 13.937722599648934
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Benefits Loads Beyond System Boundaries D : -3.4588208385823687
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.8772464203587095
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.0533903736656245
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.0014055127285174296
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.0008173285247914558
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.8192621768006801
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.0023710286390959674
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0026109529783741045
    • Materials For Energy Recovery Kg Total Life Cycle : 0.00000000919438025944
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0.00000000919438025944
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 0.9323233278206504
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.05321014508009465
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.002022067028707462
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.8770911157118483
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 1.6230293926094554
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.56994224763303
    • Net Use Of Fresh Water M3 Distribution A4 : 0.00004186279315603232
    • Net Use Of Fresh Water M3 Installation A5 : 0.0012614610305432246
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 1.0411992151722231
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.010584605980503129
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.025131410573650256
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 205.40664292706248
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 22.10812210523341
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.01661963793729014
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.2781590349577898
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 181.83859650006264
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 1.1651456488713394
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -6.91471118481633
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.00001489717073861835
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.00000934121629761512
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.00000000072579783628
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.00000000843365992038
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.00000540410865160895
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.00000014268633163762
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.00000052867668750267
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 2.840257687132482
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.19785208365414703
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.0038891056638736426
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.0013049831992758554
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 2.6304955799853285
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.006715934629856827
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.009739167108873091
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.053936171646573744
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.014919696984082579
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.00001183701189400525
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000342527734131665
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.03806045083328041
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0009099340439035743
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.005125342514154115
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 12.921358249152881
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.5648516199319453
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.01541915276999626
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.005691582761095669
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 12.310771144580068
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.024624749109775548
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.02889713115169915
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 34.36108033599856
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 34.36108033599856
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -12.997392240996694
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 39553.25266925452
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 1120.4381081126223
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 6.613865875785691
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 7.189915807800072
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 38381.68173202018
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 37.32904743813786
    • Total Use Of Primary Energy During The Life Cycle Mj Benefits Loads Beyond System Boundaries D : -92.72174659288508
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 6212.155389595681
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 27.51854884521016
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.008814136480402229
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.8340997952415575
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 6182.985170073159
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.8087567455902522
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -3.680845775328613
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 34.36108033599856
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 34.36108033599856
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -12.997392240996694
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 33306.736199322855
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 1058.558478931413
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 6.605051739305288
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 6.355816012558516
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 32198.69656194703
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 36.52029069254761
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -76.0435085765598
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 3.3445441338069095
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 3.3445441338069095
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0.8867475110947115
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 6208.810845461874
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 24.174004711403256
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.008814136480402229
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.8340997952415575
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 6182.985170073159
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.8087567455902522
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -4.5675932864233255
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.6226518298327227
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.6226518298327227
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
    • Water Use M3 Eq Total Life Cycle : 69.41981180166421
    • Water Use M3 Eq Manufacturing A1 A3 : 24.189733831645384
    • Water Use M3 Eq Distribution A4 : 0.0017980069660515875
    • Water Use M3 Eq Installation A5 : 0.05416520766799212
    • Water Use M3 Eq Maintenance B2 : 0
    • Water Use M3 Eq Repair B3 : 0
    • Water Use M3 Eq Replacement B4 : 0
    • Water Use M3 Eq Operational Energy Use B6 : 44.71950629164698
    • Water Use M3 Eq End Of Life C1 C4 : 0.4546084637377927
    • Water Use M3 Eq Benefits Loads Beyond System Boundaries D : -0.7947956728133354
    • Air Pollution M3 Total Life Cycle : 0
    • Air Pollution M3 Manufacturing A1 A3 : 0
    • Air Pollution M3 Distribution A4 : 0
    • Air Pollution M3 Installation A5 : 0
    • Air Pollution M3 Maintenance B2 : 0
    • Air Pollution M3 Repair B3 : 0
    • Air Pollution M3 Replacement B4 : 0
    • Air Pollution M3 Operational Energy Use B6 : 0
    • Air Pollution M3 End Of Life C1 C4 : 0
    • Air Pollution M3 Benefits Loads Beyond System Boundaries D : 0
    • Water Pollution M3 Total Life Cycle : 0
    • Water Pollution M3 Manufacturing A1 A3 : 0
    • Water Pollution M3 Distribution A4 : 0
    • Water Pollution M3 Installation A5 : 0
    • Water Pollution M3 Maintenance B2 : 0
    • Water Pollution M3 Repair B3 : 0
    • Water Pollution M3 Replacement B4 : 0
    • Water Pollution M3 Operational Energy Use B6 : 0
    • Water Pollution M3 End Of Life C1 C4 : 0
    • Water Pollution M3 Benefits Loads Beyond System Boundaries D : 0
    • Packaging Weight In G : 762.3
  • General Attributes
    • Product Or Component Type : variable speed drive
    • Range Of Product : Altivar Machine ATV340
  • Output Attributes
    • Maximum Output Voltage : 480 V
    • Relay Output Number : 2
    • Speed Drive Output Frequency : 0.1-599 Hz
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=442523108&lang=en-us
    • Take Back : No
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 1334.66168146822
    • Ambient Air Transport Temperature : -40-70 °C
    • Circularity Profile : ENVEOLI2311030EN
    • Environmental Disclosure : ENVPEP2311030EN
    • EU ROHS Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Permitted Relative Humidity During Operation : class 3K5 according to EN 60721-3
    • Permitted Relative Humidity During Storage : class 1K5 according to EN 60721-3
    • Pep Code : ENVPEP2311030EN
    • Pep Verification Date : 2024-10-01
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • Input Attributes
    • Number Of Input Phases : 3
  • Specifications
    • Country of Origin : Indonesia