SQUARE D

Industrial control transformer, Type TF, 1 phase, 1000VA, 240x480V primary, 120V secondary, 50/60Hz

1000VA CNTRL TRANS

SQD9070TF1000D1 9070TF1000D1 785901904922
1227.44 / EA
http://schema.org/OutOfStock
  • Depth: 6.3 in
  • Fuse Type: 1.50 in
  • Primary Voltage: 110 V, 115 V, 120 V, 440 V, 460 V, 480 V
  • Temperature Rise: 115 °C
  • Warranty Length: 18 mth
Control power transformers from Schneider-Electric set the industry standard for design innovation and performance. They are designed with low impedance windings for excellent voltage regulation and can accommodate the high inrush current associated with contactors, starters, solenoids, and relays. A variety of designs are available to meet the diverse needs of panel builders and machinery OEMs. The versatility of our control transformer line offers unparalleled options for design engineers. Type TF and EOF transformers consist of two primary fuse blocks and one secondary fuse block, a configuration meets the majority of overcurrent needs by panel builders and machinery OEMs. Since the fuse blocks are pre-wired and mounted on top of the transformer, the Type TF and EOF transformers have the same footprint as the Type T and Type EO units, respectively. This industrial control transformer has a power rating, of 1000 VA and is 1 phase(UL). With a primary voltage of 240 x 480V and a secondary voltage of 120V. This transformer complies to UL, CSA, CE standards. The fuse type for this transformer is CC with a fuse size of 0.41 x 1.50 in and will be mounted on the top of the unit. The temperature rise is rated at 115 °C. Dimensions for the unit are 5.8 in (H)5.25 in (W)6.3 in (D) with the winding material of copper. This design frees up space normally used for separate fuse blocks
QTY
  • Features
  • Specifications
  • Features
    • Type TF units are designed to free up space by fuse blocks pre-wired and factory installed saving you time
    • Provides reliable power using voltage regulation
    • Protects against accidental shocks through the use of touch-safe terminals
    • Conforms to the electrical characteristics in the data sheet by the Underwriters Laboratories (UL)
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Phenyl glycidyl ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL listed file E61239, CSA file LR37055 guide 184-N-90
  • Complementary Attributes
    • Rated Power In VA : 1000 VA UL, 1000 VA CSA, 1000 VA NOM, 600 VA CE
  • Important Information Attributes
    • Primary Voltage : 240 x 480 V 120 V, 230 x 460 V 115 V, 220 x 440 V 110 V
    • Carbon Footprint Of The Distribution Phase A4 : 2.5180866783, 3 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 2 kg CO2 eq., 2.4793945043
    • Carbon Footprint Of The Installation Phase A5 : 0.4952942191, 0.5 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 38 kg CO2 eq., 38.2983735652
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 6 310 kg CO2 eq., 6310.3972304295
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Manufacturer : Schneider Electric
    • Device Type : Transformer - dry
    • Serviceability : No
    • Traceability : No
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Electrical Connection : screw clamp terminals
    • Energy Efficiency Optimized : False
    • Fuse Type : 0.41 x 1.50 in CC top
    • Insulation Temperature : 180 °C
    • Material : copper: winding
    • Package Weight Lbs : 9.888 kg
    • Phase : 1 phase
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : Industrial Control Transformer
    • Range Of Product : TF
    • Returnability : Yes
    • Sustainable Packaging : No
    • Temperature Rise : 115 °C
    • Total Lifecycle Carbon Footprint : 6 354 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Medium Desc : Industrial control transformer, Type TF, 1 phase, 1000VA, 240x480V primary, 120V secondary, 50/60Hz
    • Stocking Flag : N
    • Product Kit Identifier : N
    • Pep Code : ENVPEP1308008EN
    • Database Version : 2016-11
    • Pep Verification Date : 2020-11-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Convert distribution voltage of either 240V or 480V to required control voltage of 120V, units are specifically design to limit voltage drop during high inrush currents from control devices, during 20 years
    • Functional Unit Unit : unité (unit)
    • Energy Model Manufacturing A1 A3 2 : Energy model used: Mexico
    • Energy Model Installation A5 2 : Electricity mix; AC; 120V; US
    • Energy Model Use B6 2 : Electricity mix; AC; 120V; US
    • Energy Model End Of Life C1 C4 2 : Electricity mix; AC; 120V; US
    • Global Commercial Status : Commercialised
  • Environment Attributes Main
    • Take Back : No, Nej
    • China ROHS Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • EU ROHS Directive : Compliant By Exemption , Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 6354.1883793964
    • Environmental Disclosure : ENVPEP1308008EN
    • Nema Degree Of Protection : not rated (open device)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Product Compatibility : FSC2
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1308008EN
    • Pep Verification Date : 2020-11-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Phase : 1 phase
    • Product Or Component Type : Industrial Control Transformer
    • Range Of Product : TF
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 6.3 in