Timing Relay - One Minute Off-Delay with 240VAC Coil with No Contacts

TIMING RELAY - ONE MINUTE OFF-

SQD8501XO00XTD1V03Y414 8501XO00XTD1V03Y414 SQD8501XO00XTD1V03Y414
0.00 / EA
http://schema.org/OutOfStock
  • Certifications: CSA LR60905 Class 3211 03, UL Listed File E78403 CCN NKCR
  • Depth: 6.55 in
  • Height: 3.5 in
  • Line Rated Current: 10 A, 5 A
  • Warranty Length: 18 mth
  • Width: 2.23 in
QTY
  • Specifications
  • Environment
    • Product Certifications : CSA LR60905 class 3211 03 || UL listed file E78403 CCN NKCR
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI1310013
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1310013EN
    • Sustainable Offer Status : Green Premium product
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • [Uc] Control Circuit Voltage : 220 V AC 50 Hz || 240 V AC 60 Hz
    • [Icm] Rated Short-Circuit Making Capacity : 60 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 30 A 240 V AC inductive control circuit UL 508 || 15 A 480 V AC inductive control circuit UL 508 || 12 A 600 V AC inductive control circuit UL 508 || 10 A <= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301...600 V DC inductive control circuit UL 508 || 4 A 125 V DC inductive control circuit UL 508
    • Height : 3.5 in
    • Ambient Air Temperature For Operation : -40-160 °F
    • Time Delay Range : 0.2...60 s
    • Control Circuit Voltage Limits : operational 0.85...1.1 Uc AC 50/60 Hz
    • Mounting Support : panel
    • Hold-In Power Consumption In Va : 23-23 VA 60 Hz || 25-25 VA 50 Hz
    • Electrical Connection : ring tongue
    • Contacts Type And Composition : without
    • Rated Breaking Capacity : 6 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 3 A 240 V AC inductive control circuit UL 508 || 1.5 A 480 V AC inductive control circuit UL 508 || 1.2 A 600 V AC inductive control circuit UL 508 || 10 A <= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301...600 V DC inductive control circuit UL 508 || 4 A 125 V DC resistive control circuit UL 508
    • Operating Time : 15 ms - pick-up || 16 ms - drop-out
    • Awg Gauge : AWG 18...AWG 12 copper
    • Width : 2.23 in
    • Tightening Torque : control circuit 1.02-1.36 N.m screw terminal
    • Time Delay Type : off-delay
    • Depth : 6.55 in
    • Inrush Power In Va : 148-148 VA 60 Hz || 143-143 VA 50 Hz
  • Specifications
    • Line Rated Current : 10 A AC || 5 A DC
    • Relay Type : timing
    • Range Of Product : 8501X
    • Poles Description : 0P
    • Product Or Component Type : relay
    • Maximum Switching Voltage : 600 V AC