Thermal overload relay, electronic, TeSys Giga, 160A to 630A, Class 5E to 30E, push-in control connection

THERMAL OVERLOAD RELAY, ELECTR

SQDLR9G630 LR9G630 3606481912589
2434.75 / EA
http://schema.org/OutOfStock
  • Depth: 186 mm
TeSys LR9G 630A thermal overload relay is compatible with TeSys Giga high power contactor, push-in control connection. It provides phase imbalance, phase failure, in-built ground-fault and single-phase loads protections. It is available for manual and auto reset options and LED indicator for Motor ON and pre-trip alarm. Tripping classes is selectable from class 5E to class 30E to suit different application needs from fast tripping, general purpose and high inertia loads. It is suitable for independent mounting or direct mounting with LC1G contactors. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature without derating up to 3000m altitude. Multi standards certified (CE,CB,CCC,cULus,EAC,KC,RCM,Marine). Unique QR code provides quick access to complete product data.
QTY
  • Product Description
  • Features
  • Specifications
TeSys LR9G 630A thermal overload relay is compatible with TeSys Giga high power contactor, push-in control connection. It provides phase imbalance, phase failure, in-built ground-fault and single-phase loads protections. It is available for manual and auto reset options and LED indicator for Motor ON and pre-trip alarm. Tripping classes is selectable from class 5E to class 30E to suit different application needs from fast tripping, general purpose and high inertia loads. It is suitable for independent mounting or direct mounting with LC1G contactors. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature without derating up to 3000m altitude. Multi standards certified (CE,CB,CCC,cULus,EAC,KC,RCM,Marine). Unique QR code provides quick access to complete product data.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel (Metallic), which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Color : dark grey
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8, PB
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electromagnetic Compatibility : EMC immunity conforming to IEC 60947-4-1emission tests criteria A conforming to IEC 60947-4-1, immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3voltage dips and interruptions immunity test conforming to SEMI F47
    • Local Signalling : LED, trip indicator
    • Mounting Support : direct on contactor, plate
    • Network Frequency : 30...60 Hz, 100 Hz
    • Protection Type : phase imbalance 0-5 s - alarm circuit UL 60947-4-1, ground fault protection 0-1 s - alarm circuit IEC 60947-4-1, ground fault protection 0-1 s - alarm circuit UL 60947-4-1, phase loss 0-4 s - alarm circuit, phase imbalance 0-5 s - alarm circuit IEC 60947-4-1
    • Reset : automatic reset, manual
    • Certificate Agency : CB Scheme, CCC, cULus, UKCA, ATEX, EU-RO-MR by DNV-GL, EAC
    • Connections - Terminals : power circuit: bar - busbar cross section: 50 x 10 mm, power circuit: lugs-ring terminals 1 300-300 mm², control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end, control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: push-in 2 0.5-1.0 mm² with cable end
    • Carbon Footprint Of The Distribution Phase [A4] : 0.5101636186118972, 0.5 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 5 kg CO2 eq., 5.017797406826899
    • Carbon Footprint Of The Installation Phase [A5] : 0.10723822617490514, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 31 kg CO2 eq., 31.319061943344423
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 1 015 kg CO2 eq., 1014.6580185636406
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-06-27
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : No
    • Traceability : No
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2105014
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2121
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Contacts Type And Composition : 1 NO + 1 NC
    • Device Short Name : LR9G
    • Mechanical Durability : 7000 cycles
    • Mechanical Robustness : vibrations 5-300 Hz 6 gn contactor openshocks 15 gn 11 ms contactor closed
    • Network Type : AC
    • Overvoltage Category : III
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys LRG
    • Product Or Component Type : electronic thermal overload relay
    • Protective Treatment : TH
    • Range : TeSys
    • Relay Application : motor protection
    • Returnability : Yes
    • Software Version : v6.1
    • Sustainable Packaging : No
    • Thermal Overload Class : class 5E...30E IEC 60947-4-1
    • Thermal Protection Adjustment Range : 160-630 A
    • Tightening Torque : 58 N.m
    • Total Lifecycle Carbon Footprint : 1 052 kg CO2 eq.
    • Tripping Threshold : 1.125 +/- 0.07 In IEC 60947-4-1
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • R Thermal Protection Adj Range : 160-630 A
    • Pep Code : ENVPEP2105014EN
    • Database Version : 2023-02
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime In Y : 20
    • Energy Model - Manufacturing [A1-a3] : China, CN
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2018; China, CN
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2018; China, CN
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2018; China, CN
    • Recyclability Potential In % : 42
    • Height Nominal : 148 mm
    • Width Nominal : 211 mm
    • [Ith] Conventional Free Air Thermal Current : 5 A
    • [Uc] Control Circuit Voltage : 24...500 V AC 50/60 Hz24...250 V DC
    • [Ue] Rated Operational Voltage : 1000 V AC 50/60 Hz
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV
    • Halogen-free Status : Halogen free plastic parts product
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 4.540 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536490075
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -60-80 °C, -60-80 °C
    • Ambient Air Transport Temperature : -25-60 °C, -25-60 °C
    • Ip Degree Of Protection : IP2X front face with shrouds IEC 60529, IP2X front face with shrouds VDE 0106
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C at Uc, -40-60 °C at Uc-40-60 °C at Uc, -40-60 °C at Uc
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 1051.6122797585988
    • Ambient Air Temperature For Operation : -25-60 °C-25-60 °C
    • Circularity Profile : ENVEOLI2105014
    • Environmental Disclosure : ENVPEP2105014EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2105014EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : electronic thermal overload relay
  • ETIM
    • ETIM 8 : EC000106
    • ETIM 9 : EC000106
  • Surge Protection And Filtering Attributes
    • Surge Withstand : 4 kV
  • Specifications
    • Country of Origin : Brazil, China, France, Indonesia, Philippines, United States
    • Depth : 186 mm