SQUARE D

Tesys motor starter kit, LC1D09BD contactor, LR9D08 thermal overload relay

Tesys motor starter kit, LC1D09BD contactor, LR9D08 thermal overload relay

SQDLR9D08KITD09BD LR9D08KITD09BD 3606486288092
151.28 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Dielectric Strength: 50 Hz, 6 kV
  • Height: 3.03 in
  • Width: 1.77 in
TeSys motor starter kits combine a TeSys LC1D contactor and a TeSys LR9D overload relay to make an IEC starter. This starter has a LC1D09BD contactor and a LR9D08 electronic overload relay. The LC1D09BD contactor has a 9 ampere resistive and horsepower ratings. The LR9D08 electronic overload relay has a current setting of 1.6 to 8 amperes. This starter is UL listed and CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
TeSys motor starter kits combine a TeSys LC1D contactor and a TeSys LR9D overload relay to make an IEC starter. This starter has a LC1D09BD contactor and a LR9D08 electronic overload relay. The LC1D09BD contactor has a 9 ampere resistive and horsepower ratings. The LR9D08 electronic overload relay has a current setting of 1.6 to 8 amperes. This starter is UL listed and CSA certified.
  • Features
    • Customizable with hundreds of combinations
    • Robust design and reliable build
    • Easy to Service with replaceable parts
    • Available in NEMA Sizes 00 to 7
    • 600 Volts maximum
  • Complementary Attributes
    • Irms Rated Making Capacity : 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Maximum Horse Power Rating : 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors5 hp at 460/480 V AC 50/60 Hz for 3 phase motors7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
    • Ui Rated Insulation Voltage : signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 1000 Vsignalling circuit 690 V, power circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
    • Control Circuit Type : DC standard
    • Control Circuit Voltage Limits : drop-out 0.1...0.25 Uc DC 60 °C)operational 0.7...1.25 Uc DC 60 °C)
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 250 A at 440 V for power circuit conforming to IEC 60947
    • Uc Control Circuit Voltage : 24 V DC
    • Ue Rated Operational Voltage : 690 V power circuit660 V signalling circuitpower circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
    • Uimp Rated Impulse Withstand Voltage : 6 kV6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 5 A gG signalling circuit, 5 A BS signalling circuit10 A gG for signalling circuit conforming to IEC 60947-5-125 A gG at <= 690 V coordination type 1 for power circuit20 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : motor control, resistive load
    • Control Type : Red push-button stop and manual reset, White 2 microswitches adjustable trip classRed knob automatic resetWhite dial full-load current adjustment
    • Electromagnetic Compatibility : surge withstand 2 kV common mode IEC 61000-4-5, resistance to electrostatic discharge 8 kV IEC 61000-4-2, immunity to radiated radio-electrical interference 10 V/m IEC 61000-4-3immunity to fast transients 2 kV IEC 61000-4-4
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations 10...150 Hz 6 Gn) IEC 60068-2-6shocks 11 ms 15 gn) IEC 60068-2-7, vibrations contactor open2 Gn, 5...300 Hzvibrations contactor closed4 Gn, 5...300 Hzshocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
    • Motor Power Kw : 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)4 kW at 380...400 V AC 50/60 Hz (AC-3), 4 kW at 415...440 V AC 50/60 Hz (AC-3)5.5 kW at 500 V AC 50/60 Hz (AC-3), 5.5 kW at 660...690 V AC 50/60 Hz (AC-3)2.2 kW at 400 V AC 50/60 Hz (AC-4)
    • Mounting Support : under contactorplate, with specific accessories, , with specific accessories, plate, rail
    • Power Range : 1.1-2 kW 200-240 V 3 phase2.2-3 kW 380-440 V 3 phase, 4-6 kW 380-440 V 3 phase, 4-6 kW 480-500 V 3 phase
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals Philips No 2control circuit 0.8 N.m screw clamp terminalspower circuit 3.1 N.m screw clamp terminalspower circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
    • Utilisation Category : AC-4, AC-1, AC-3
    • Connections Terminals : power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable endpower circuit screw clamp terminals 2 1-4 mm²solid without cable endcontrol circuit screw clamp terminals 2 1-4 mm²flexible without cable endcontrol circuit screw clamp terminals 1 1-4 mm²flexible with cable endcontrol circuit screw clamp terminals 2 1-2.5 mm²flexible with cable endcontrol circuit screw clamp terminals 1 1-4 mm²solid without cable endcontrol circuit screw clamp terminals 2 1-4 mm²solid without cable end, control circuit screw clamp terminals 1 2.5-2.5 mm² solid or flexible - without cable endpower circuit screw clamp terminals 1 16-16 mm² solid or flexible - without cable endpower circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²solid without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end
    • Certificate Agency : LROS (Lloyds register of shipping), UL, GOST, DNV, GL, BV, RINA, TÜV, CSA, cULus, CCC
    • Ith Conventional Free Air Thermal Current : 5 A signalling circuit, 25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-06-30
    • Return Indicator : N
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1502001EN
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2020
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Contact Compatibility : M4
    • Contactor Coil Voltage : 24 V DC standard
    • Dielectric Strength : 6 kV 50 Hz IEC 60255-5
    • Energy Efficiency Optimized : False
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Inrush Power In W : 5.4-5.4 W 20 °C)
    • Mechanical Durability : 30 Mcycles
    • Motor Starter Type : direct on-line contactor
    • Number Of Poles : 3P
    • Operating Time : 53.55...72.45 ms closing16...24 ms opening
    • Overvoltage Category : III
    • Phase Failure Sensitivity : phase difference > 40% 3-3 s IEC 60947-4-1
    • Pole Contact Composition : 3 NO
    • Power Consumption In W : 300 mW
    • Power Dissipation Per Pole : 1.56 W AC-10.2 W AC-3
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : motor starter
    • Protective Treatment : TH IEC 60068-2-30
    • Range : TeSys
    • Relay Application : motor protection
    • Returnability : No
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : No
    • Thermal Overload Class : class 5…30
    • Thermal Protection Adjustment Range : 0.4-2 A
    • Time Constant : 28 ms
    • Time Range : 1.5...4 min - automatic reset time
    • Tripping Threshold : 1.25 In IEC 60947-4-1
    • Height Nominal : 72.5 mm
    • Height Useful : 77 mm
    • Width Nominal : 45 mm
    • Width Real : 45 mm
    • Nbr. Of Units In Pkg. : 1
    • Customs Code : 8537109170
    • Hold In Power Consumption In W : 5.4-5.4 W 20 °C
    • Warranty In Months : 18
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -25-70 °C IEC 60255-8, -25-70 °C IEC 60255-8, -5-60 °C, -5-60 °C, -25-70 °C IEC 60255-8, -25-70 °C IEC 60255-8
    • Ip Degree Of Protection : front face IP20 IEC 60529, front face IP20 VDE 0106, IP20 front face IEC 60529
    • Permissible Ambient Air Temperature Around The Device : -40-70 °C at Uc, -40-70 °C at Uc-40-70 °C at Uc, -40-70 °C at Uc
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Ambient Air Temperature For Storage : -60-80 °C-60-80 °C
    • Circularity Profile : ENVEOLI1502001EN
    • Environmental Disclosure : ENVPEP1502001EN
    • Eu Rohs Directive : Compliant By Exemption
    • Operating Altitude : 6561.68 ft (2000 m) without derating9842.52 ft (3000 m) without derating
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Pep Code : ENVPEP1502001EN
  • General Attributes
    • Product Or Component Type : motor starter
  • Specifications
    • Country of Origin : United States
    • Height : 3.03 in