• Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Ui Rated Insulation Voltage : 2000 V
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Current Consumption : <= 40 mA voltage output, <= 40 mA voltage output, <= 60 mA current output, <= 60 mA current output<= 40 mA voltage output, <= 40 mA voltage output, <= 60 mA current output, <= 60 mA current output
    • Fire Resistance : 850 °C IEC 60695-2-1, 850 °C UL
    • Measurement Error : +/- 0.5 % of full scale 3 or 4 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 0.5 % of full scale 3 or 4 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 0.5 % of full scale 3 or 4 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 0.5 % of full scale 3 or 4 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 1 % of full scale 2 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 1 % of full scale 2 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 1 % of full scale 2 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 1 % of full scale 2 wires)20 °C temporary performance degradation when subject to electromagnetic interference)+/- 0.5 % of full scale 3 or 4 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 0.5 % of full scale 3 or 4 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 0.5 % of full scale 3 or 4 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 0.5 % of full scale 3 or 4 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 1 % of full scale 2 wires)20 °C temporary performance degradation when subject to electromagnetic interference), +/- 1 % of full scale 2 wires)20 °C temporary performance degradation when subject to electromagnetic interference)
    • Protection Type : reverse polarity protection on output, overvoltage protection on output (+/- 30 V), reverse polarity protection on power supply, short-circuit protection on output
    • Repeat Accuracy : +/- 0.2 % full scale 20 °C, +/- 0.2 % full scale 20 °C, +/- 0.6 % full scale 60 °C, +/- 0.6 % full scale 60 °C+/- 0.2 % full scale 20 °C, +/- 0.2 % full scale 20 °C, +/- 0.6 % full scale 60 °C, +/- 0.6 % full scale 60 °C
    • Safety Reliability Data : MTTFd = 32.9 years, B10d = 30437
    • Certificate Agency : GL, CSA, UL
    • Disturbance Radiated/Conducted : CISPR 11, CISPR 22 group 1 - class B
    • Carbon Footprint Of The Distribution Phase A4 : 0.24772669157832428, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.1672254518300461, 0.2 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0009126232522786244
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 5 kg CO2 eq., 4.696304851035895
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 19 kg CO2 eq., 19.105800523323484
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-08-07
    • Return Indicator : Y
    • Weee Scope : Out
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2511011EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1930
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Electromagnetic Compatibility : electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
    • Fixing Mode : clip-on (35 mm symmetrical DIN rail)fixed (mounting plate)
    • Local Signalling : LED (green) for power ON
    • Marking : CE
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : converter for Universal Pt100 probes
    • Range Of Product : Harmony Analog
    • Resistance To Fast Transients : 1 kV IEC 61000-4-4 on input-output)2 kV IEC 61000-4-4 on power supply)
    • Returnability : Yes
    • Shock Resistance : 50 gn 11 ms IEC 60068-2-27
    • Software Version : v6.2.5-6
    • Sustainable Packaging : Yes
    • Temperature Coefficient : 150 ppm/°C
    • Tightening Torque : 0.6-1.1 N.m
    • Total Lifecycle Carbon Footprint : 24 kg CO2 eq.
    • Vibration Resistance : 5 gn (f= 10-100 Hz) conforming to IEC 60068-2-6
    • Database Version : 2024-01
    • Data Source : extrapolated product
    • Nbr. Of Units In Pkg. : 1
    • Customs Code : 8536490075
    • Warranty In Months : 18
    • Product Weight In G : 125
    • Functional Unit Description : This voltage/current converter is part of the harmony analog range. It converts both AC and DC electrical power signals and operates on a 24 V DC supply. The device also extends the connection distance between a sensor and the measurement acquisition system and providing greater installation flexibility. Complies with IEC standards UL and CSA certified which making it suitable for universal applications. Designed for quick, intuitive configuration and it offers ease of use with fixed input and output values aligned with market requirements.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 39.42
    • Recyclability Potential In % : 62
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : 0-50 °C mounting side by side, 0-60 °C 2 cm spacing
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 24.21797014102003
    • Circularity Profile : ENVEOLI2511011EN
    • Environmental Disclosure : ENVPEP2511011EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 terminal block)IP50 housing)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2511011EN
    • Pep Verification Date : 2025-11-11
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : converter for Universal Pt100 probes
    • Range Of Product : Harmony Analog
  • ETIM
    • ETIM 8 : EC002653
    • ETIM 9 : EC002653
  • Output Attributes
    • Analogue Output Current : -30-0 mA no input or input wire broken, -30-0 mA no input or input wire broken-30-0 mA no input or input wire broken, -30-0 mA no input or input wire broken, 22-30 mA no input or input wire broken
    • Analogue Output Type : current 0...20 mA, current 4...20 mAvoltage 0...10 V
    • Analogue Output Voltage : -15...-11 V no input or input wire broken, -15...-11 V no input or input wire broken-15...-11 V no input or input wire broken, -15...-11 V no input or input wire broken, 11...15 V no input or input wire broken
  • Surge Protection And Filtering Attributes
    • Surge Withstand : 0.5 kV 1.2/50 µs IEC 61000-4-5
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Analogue Input Type : RTD - 100...100 °C/- 148...212 °F Pt 100 2, 3 or 4 wires
  • Specifications
    • Country of Origin : Indonesia