SQUARE D

Harmony analog, Temperature transmitter, 0..100 °C/32..212 °F, for Optimum Pt100 probes

Harmony analog, Temperature transmitter, 0..100 °C/32..212 °F, for Optimum Pt100 probes

SQDRMPT33BD RMPT33BD 785901566205
113.00 / EA
  • Certifications: CSA, GL, UL
  • Current: 40 mA, 60 mA
  • Net Weight: 0.12 kg
  • Operating Temperature: 0-50 °C Mounting Side By Side || 0-60 °C 2 Cm Spacing
  • Standard: DIN 43760, EN/IEC 60584-1, EN/IEC 60751, EN/IEC 60947-1
  • Storage Temperature: -40-85 °C
  • Warranty Length: 18 mth
This temperature transmitter is part of the range of Zelio Analog interfaces. It is designed to convert signal of Pt100 probe into standard electrical signal which is compatible with automation platforms, controllers. Its supply voltage is 24V DC, non isolated. It also allows the connection distance between a sensor and the measurement acquisition device to be increased. The cables used to connect the converters to process equipment (PLCs) are standard cables, which are more cost effective than extension cables or compensation cables suitable for low level signals for Pt100 probes or thermocouples. Conforming to IEC standards, UL and CSA certified, this converter is suitable for universal use.
  • Product Description
  • Specifications
This temperature transmitter is part of the range of Zelio Analog interfaces. It is designed to convert signal of Pt100 probe into standard electrical signal which is compatible with automation platforms, controllers. Its supply voltage is 24V DC, non isolated. It also allows the connection distance between a sensor and the measurement acquisition device to be increased. The cables used to connect the converters to process equipment (PLCs) are standard cables, which are more cost effective than extension cables or compensation cables suitable for low level signals for Pt100 probes or thermocouples. Conforming to IEC standards, UL and CSA certified, this converter is suitable for universal use.
  • Contractual warranty
    • Warranty : 18 months
  • Environment
    • Resistance To Fast Transients : 1 kV IEC 61000-4-4 on input-output) || 2 kV IEC 61000-4-4 on power supply)
    • Product Certifications : UL || GL || CSA
    • Standards : DIN 43760 || EN/IEC 60584-1 || EN/IEC 60751 || EN/IEC 60947-1
    • Shock Resistance : 50 gn 11 ms IEC 60068-2-27
    • Electromagnetic Compatibility : electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2
    • Vibration Resistance : 5 gn 10-100 Hz)IEC 60068-2-6
    • Disturbance Radiated/Conducted : CISPR 22 group 1 - class B || CISPR 11
    • Ambient Air Temperature For Storage : -40-85 °C
    • Ip Degree Of Protection : IP20 terminal block) || IP50 housing)
    • Ambient Air Temperature For Operation : 0-50 °C mounting side by side || 0-60 °C 2 cm spacing
    • Pollution Degree : 2 IEC 60664-1
    • Fire Resistance : 850 °C IEC 60695-2-1 || 850 °C UL
  • Offer Sustainability
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI1607005EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Environmental Disclosure : ENVPEP1607005EN
    • Mercury Free : Yes
    • Rohs Exemption Information : Yes
    • Sustainable Offer Status : Green Premium product
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Surge Withstand : 0.5 kV 1.2/50 µs IEC 61000-4-5
    • Analogue Output Current : -30-0 mA no input or input wire broken || 22-30 mA no input or input wire broken
    • Repeat Accuracy : +/- 0.2 % full scale 20 °C || +/- 0.6 % full scale 60 °C
    • Temperature Coefficient : 150 ppm/°C
    • [Us] Rated Supply Voltage : 24 V DC non isolated +/- 20 %
    • Fixing Mode : clip-on 35 mm symmetrical DIN rail) || fixed mounting plate)
    • Local Signalling : for power ON LED (green)
    • Marking : CE
    • [Ui] Rated Insulation Voltage : 2000 V
    • Clamping Connection Capacity : 2 x 1.5 mm² || 1 x 2.5 mm²
    • Protection Type : short-circuit protection on output || reverse polarity protection on output || overvoltage protection on output (+/- 30 V) || reverse polarity protection on power supply
    • Current Consumption : <= 40 mA voltage output || <= 60 mA current output
    • Safety Reliability Data : MTTFd = 43.9 years || B10d = 40564
    • Analogue Output Voltage : -15...-11 V no input or input wire broken || 11...15 V no input or input wire broken
    • Net Weight : 0.12 kg
    • Tightening Torque : 0.6-1.1 N.m
    • Maximum Wiring Resistance : 0.2 Ohm 2 wires
    • Measurement Error : +/- 0.5 % of full scale 3 or 4 wires)20 °C || +/- 1 % of full scale 2 wires)20 °C || +/- 10 % of full scale20 °C electromagnetic interference of 10 V/m)
  • Product Or Component Type : converter for Optimum Pt100 probes
  • Range Of Product : Harmony Analog
  • Analogue Output Type : current 4...20 mA <= 500 Ohm || voltage 0...10 V >= 100 kOhm
  • Analogue Input Type : temperature probe 0...100 °C/32..212 °F Pt 100 2, 3 or 4 wires