Mini contactor, TeSys SK, 2P(2NO), AC-3, 690V 5A, 220V AC coil

TESYS SK MINI CONTACTOR - 2P (

SQDLC1SKGC200M7 LC1SKGC200M7 3389110563047
127.88 / EA
http://schema.org/OutOfStock
  • Depth: 55.5 mm
  • Warranty Length: 18 mth
TeSys SKGC mini-contactor, 2 poles (2NO), for non-inductive load applications up to 20A/690V AC-1, and for 1-phase motor control applications up to 5A/690V AC-3. It provides a 220V 50/60Hz AC control circuit, a transparent protective cover to prevent front face access, connection by screw terminals. For operating rates until 1200 cycles/hour and ambient temperature -20/+50°C, it procures high reliability and durability. For use in modular panels, compact (27mm width), clipping on 35mm DIN rail. Location available to insert a suppressor module LA4SK (to be ordered separately). Multi standards certified (IEC, UL, CSA).
QTY
  • Product Description
  • Features
  • Specifications
TeSys SKGC mini-contactor, 2 poles (2NO), for non-inductive load applications up to 20A/690V AC-1, and for 1-phase motor control applications up to 5A/690V AC-3. It provides a 220V 50/60Hz AC control circuit, a transparent protective cover to prevent front face access, connection by screw terminals. For operating rates until 1200 cycles/hour and ambient temperature -20/+50°C, it procures high reliability and durability. For use in modular panels, compact (27mm width), clipping on 35mm DIN rail. Location available to insert a suppressor module LA4SK (to be ordered separately). Multi standards certified (IEC, UL, CSA).
  • Features
    • It is desingned with transparent protective cover at front for double security
    • Good adaptability: possible to insert a suppressor module
    • High durability & stable performance: up to 1200 cycles/hour for operating rates
    • Reliable in high and low temperature environment
    • Modularity design and compact size for easy maintenance, save time and space on installation
    • Wide application with multi standards certifications
  • Conformance Attributes
    • Product Certifications : CB Scheme, CE, UKCA, EAC, cULus
    • Standards : EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C), drop-out: 0.2...0.75 Uc at 50/60 Hz (at <55 °C)
    • IRMS Rated Making Capacity : 50 A AC conforming to NF C 63-110, 50 A AC conforming to IEC 60947
    • Rated Breaking Capacity : 40 A at <= 400 V conforming to NF C 63-110, 40 A at <= 400 V conforming to IEC 60947
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Operating Rate : 1200 cyc/h
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Contactor Application : motor control, resistive load
    • Operating Time : 6...8 ms coil de-energisation and NO opening, 7...14 ms coil energisation and NO closing
    • Protective Treatment : TC IEC 60068, TC DIN 50015
    • Utilisation Category : AC-1, AC-3
    • Ie Rated Operational Current2 : 5 A at <= 400 V AC AC-3, 20 A (at <50 °C) AC AC-1
    • Ui Rated Insulation Voltage2 : power circuit 690 V BS 5424, power circuit 690 V IEC 60947, power circuit 690 V UL 508, power circuit 690 V VDE 0110 group C, power circuit 690 V CSA C22.2 No 14
    • Carbon Footprint Of The Distribution Phase A4 : 0.05132471286393272, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.2 kg CO2 eq., 0.21846388581500262
    • Carbon Footprint Of The Installation Phase A5 : 0.007904081068694103, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.7 kg CO2 eq., 0.7152454472070074
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 51 kg CO2 eq., 51.34125131495782
    • Connections Terminals : connector 1 1.5-6 mm²solid, connector 2 1.5-4 mm²solid, connector 1 0.5-6 mm²flexible without cable end, connector 2 0.35-2.5 mm²flexible without cable end, connector 1 0.35-6 mm²flexible with cable end
    • Connections Terminals3 : connector 1 1.5-6 mm²solid, connector 2 1.5-4 mm²solid, connector 1 0.5-6 mm²flexible without cable end, connector 2 0.35-2.5 mm²flexible without cable end, connector 1 0.35-6 mm²flexible with cable end, connector 2 0.35-1.5 mm²flexible with cable end
    • Ie Rated Operational Current5 : 5 A at <= 400 V AC AC-3, 20 A (at <50 °C) AC AC-1
    • Ui Rated Insulation Voltage5 : power circuit 690 V BS 5424, power circuit 690 V IEC 60947, power circuit 690 V UL 508, power circuit 690 V VDE 0110 group C, power circuit 690 V CSA C22.2 No 14
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1503003
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Associated Fuse Rating : 20 A gI at <= 440 V for power circuit
    • Average Impedance : 4 mOhm - Ith 20 A 50 Hz for power circuit
    • Compatibility Code : LC1SKGC
    • Device Short Name : LC1SKGC
    • Energy Efficiency Optimized : False
    • Heat Dissipation : 1.4-1.4 W 50/60 Hz
    • Hold In Power Consumption In VA : 4.2-4.2 VA 50/60 Hz (at 20 °C)
    • Inrush Power In VA : 16-16 VA 50/60 Hz (at 20 °C)
    • Mechanical Durability : 10 Mcycles
    • Mounting Support : rail
    • Package Weight Lbs : 121.700 g
    • Pole Contact Composition : 2 NO
    • Poles Description : 2P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : mini contactor
    • Range : TeSys
    • Range Of Product : TeSys SK
    • Returnability : No
    • Sustainable Packaging : Yes
    • Tightening Torque : power circuit 0.8 N.m connector pozidriv No 1
    • Total Lifecycle Carbon Footprint : 52 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Icw Rated Short Time Withstand Current2 : 40 A 55 °C for power circuit
    • Ith Conventional Free Air Thermal Current2 : 20 A (at 55 °C) for power circuit
    • Uc Control Circuit Voltage2 : 220 V AC 50/60 Hz
    • Ue Rated Operational Voltage2 : power circuit 690 V AC 50/60 Hz
    • Medium Desc : Mini contactor, TeSys SK, 2P(2NO), AC-3, 690V 5A, 220V AC coil
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP1503003
    • Database Version : 2024-01
    • Pep Verification Date : 2025-11-21
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Global Commercial Status : Commercialised
    • Product Name : TeSys SK
    • Icw Rated Short Time Withstand Current5 : 40 A 55 °C for power circuit
    • Ith Conventional Free Air Thermal Current5 : 20 A (at 55 °C) for power circuit
    • Uc Control Circuit Voltage5 : 220 V AC 50/60 Hz
    • Ue Rated Operational Voltage5 : power circuit 690 V AC 50/60 Hz
  • Environment Attributes Main
    • Take Back : No, Nej
    • China ROHS Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • EU ROHS Directive : Compliant By Exemption , Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 52.334189441912464
    • Ambient Air Temperature For Operation : -20-50 °C
    • Ambient Air Temperature For Storage : -50-70 °C
    • Circularity Profile : ENVEOLI1503003
    • Environmental Disclosure : ENVPEP1503003
    • IP Degree Of Protection : IP2X VDE 0106
    • Operating Altitude : 6561.68 ft (2000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1503003
    • Pep Verification Date : 2025-11-21
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : mini contactor
    • Range Of Product : TeSys SK
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 55.5 mm