SQUARE D

Motor circuit breaker, Tesys GV5, 150A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%

TeSys Motor Protection Circuit

SQDGV5PB150N GV5PB150N 3606481005373
1035.24 / EA
http://schema.org/OutOfStock
TeSys GV5 motor protective circuit breakers provide an efficient motor control and protection solution up to 520 amps. This 3 pole motor protective circuit breaker is rated at 150A. The thermal protection adjustable dials have settings of 58A to 130A, a selectable tripping class of 5, 10 or 20, and magnetic protection at 15 In. It has SCCR breaking capacity 18kA at 600Y/347V. This UL489 motor protective circuit breaker is has UL Listed, CSA, IEC, CCC, EAC, and Marine certifications.
QTY
  • Product Description
  • Features
  • Specifications
TeSys GV5 motor protective circuit breakers provide an efficient motor control and protection solution up to 520 amps. This 3 pole motor protective circuit breaker is rated at 150A. The thermal protection adjustable dials have settings of 58A to 130A, a selectable tripping class of 5, 10 or 20, and magnetic protection at 15 In. It has SCCR breaking capacity 18kA at 600Y/347V. This UL489 motor protective circuit breaker is has UL Listed, CSA, IEC, CCC, EAC, and Marine certifications.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : CSA, ANSI, UL Listed, NOM
  • Complementary Attributes
    • Line Rated Current : 150 A
    • UE Rated Operational Voltage : 600 V AC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electrical Connection : lugs, load, lugs, line
    • Carbon Footprint Of The Distribution Phase A4 : 0.5775543976, 0.6 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.3 kg CO2 eq., 0.3226776506
    • Carbon Footprint Of The Installation Phase A5 : 0.029878509, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 15 kg CO2 eq., 15.0417243976
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 676 kg CO2 eq., 675.7844680064
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-18
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • WEEE Applicability : Finished product
    • WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • AWG Gauge : AWG 14...AWG 3/0 aluminium/copper
    • Energy Efficiency Optimized : False
    • Package Weight Lbs : 2.268 kg
    • Phase Failure Sensitivity : yes
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : motor protection circuit breaker
    • Returnability : Yes
    • Sustainable Packaging : No
    • Thermal Protection Adjustment Range : 58-130 A
    • Tightening Torque : 5-5 N.m 2.5-95 mm² (AWG 14...AWG 3/0)
    • Total Lifecycle Carbon Footprint : 692 kg CO2 eq.
    • Trip Unit Technology : electronicMicroLogic 2.2 M,
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : cross-selling relationship
    • Pep Code : ENVPEP1610005_V2-EN
    • Pep Verification Date : 2016-12-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : Protect during 20 years the installation against overloads and short-circuits in circuit with assigned voltage up to 600Y/347VAC and 125A rated current. This protection is ensured in accordance with the following parameters:& 10- Number of poles: 3& 10- Rated short-circuit current interruption rating Ii at 480Vac = 65kA (according to UL489)& 10- Tripping curve: long time and instantanous protections
    • Functional Unit Unit : unité (unit)
    • Product Kit Identifier : N
    • Product Manager : MANISH DEV PANWAR
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 691.7563029613
    • Ambient Air Temperature For Operation : 40-40 °C
    • Environmental Disclosure : ENVPEP1610005_V2-EN
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1610005_V2-EN
    • Pep Verification Date : 2016-12-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : motor protection circuit breaker