thermal overload relays, TeSys Deca, 90...150A, class 20

thermal overload relays, TeSys Deca, 90...150A, class 20

SQDLR9D5569 LR9D5569 3389110787948
604.30 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 125 mm
  • Dielectric Strength: 1.89 kV, 50 Hz
  • Height: 118 mm
  • Net Weight: 0.885 kg
  • Warranty Length: 18 mth
  • Weight: 0.885 kg
  • Width: 115 mm
LR9D5569 is a TeSys LR9D electronic overload relay from Schneider Electric to be used with a TeSys D contactor. With a thermal range 90-150A, a tripping class 20 and phase unbalance protection, it protects motors 55 to 75kW@400V. LR9D5569 is a TeSys LR9D electronic overload relay from Schneider Electric to be combined with a TeSys D contactor. With a thermal setting range 90-150A, a tripping class 20 and phase unbalance detection, it protects motors 55 to 75kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Thermal overload protection, electronic type, with phase unbalance protection (differential), self powered (no external power supply needed). To be combined with Tesys LC1D115-D150 contactors. Light and compact, 120mm wide. Manual control with test & reset buttons, manual / automatic reset selector. High accuracy, temperature compensated to keep a precise tripping over the ambient temperature range. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. 90% reduction in energy dissipation compared to a thermal overload relay.
QTY
  • Product Description
  • Features
  • Specifications
LR9D5569 is a TeSys LR9D electronic overload relay from Schneider Electric to be used with a TeSys D contactor. With a thermal range 90-150A, a tripping class 20 and phase unbalance protection, it protects motors 55 to 75kW@400V. LR9D5569 is a TeSys LR9D electronic overload relay from Schneider Electric to be combined with a TeSys D contactor. With a thermal setting range 90-150A, a tripping class 20 and phase unbalance detection, it protects motors 55 to 75kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Thermal overload protection, electronic type, with phase unbalance protection (differential), self powered (no external power supply needed). To be combined with Tesys LC1D115-D150 contactors. Light and compact, 120mm wide. Manual control with test & reset buttons, manual / automatic reset selector. High accuracy, temperature compensated to keep a precise tripping over the ambient temperature range. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. 90% reduction in energy dissipation compared to a thermal overload relay.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : UL || CSA || CCC || UKCA
    • Mechanical Robustness : vibrations2 Gn, 5...300 Hz IEC 60068-2-6 || shocks13 Gn for 11 ms IEC 60068-2-7
    • Standards : EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5
    • Climatic Withstand : IACS E10
    • Ambient Air Temperature For Operation : -20-60 °C without derating IEC 60947-4-1
    • Dielectric Strength : 1.89 kV 50 Hz IEC 60947-1
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Ambient Air Temperature For Storage : -60-70 °C
    • Operating Altitude : <= 6561.68 ft (2000 m) without derating
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2212018
    • Packaging Without Single Use Plastic : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : d5a17874-1166-4927-b008-33d15e304a41
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI2212018
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 126.69793890788517
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 4.300183391790282
    • Carbon Footprint Of The Distribution Phase [A4] : 0.6 kg CO2 eq.
    • Pvc Free : Yes
    • Carbon Footprint Of The Installation Phase [A5] : 0.1 kg CO2 eq.
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 133 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 1.6370650693830773
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 133.33645011700477
  • Complementary
    • Network Frequency : 50-60 Hz
    • Height : 118 mm
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • [Ith] Conventional Free Air Thermal Current : 5 A signalling circuit
    • Connections - Terminals : power circuit bars || control circuit screw clamp terminals 1 0.5-1.5 mm² flexible without cable end || control circuit screw clamp terminals 2 0.5-1.5 mm² flexible without cable end || alarm circuit screw clamp terminals 1 0.5-1.5 mm² flexible without cable end
    • Phase Failure Sensitivity : tripping in 4 s +/- 20 % IEC 60947-4-1
    • [Ue] Rated Operational Voltage : 690 V AC 0...400 Hz power circuit IEC 60947-4-1
    • Switching Capacity In Ma : 0...150 mA
    • Associated Fuse Rating : 4 A gG for signalling circuit || 4 A BS for signalling circuit
    • Net Weight : 0.885 kg
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947-1
    • Maximum Voltage Drop : <2.5 V closed state
    • Supply Voltage Limits : 17-32 V
    • Tripping Threshold : 1.05 +/- 0.06 In alarm IEC 60947-4-1 || 1.12 +/- 0.06 In de-energisation IEC 60947-4-1
    • Tightening Torque : alarm circuit 0.45 N.m screw clamp terminals || power circuit 18 N.m bars M8 || control circuit 1.2 N.m screw clamp terminals
    • Control Type : Red push-button stop || Blue push-button reset
    • Mounting Support : under contactor || rail
    • Width : 115 mm
    • Depth : 125 mm
    • [Us] Rated Supply Voltage : 24 V DC
    • Temperature Compensation : -20-60 °C
  • Specifications
    • Country of Origin : France
    • Width : 115 mm
    • Height : 118 mm
    • Weight : 0.885 kg
    • Signalling Function : alarm
    • Thermal Protection Adjustment Range : 90-150 A
    • Network Type : AC
    • Relay Application : motor protection
    • Product Or Component Type : electronic thermal overload relay
    • Product Name : TeSys LRD || TeSys Deca
    • Thermal Overload Class : class 20 IEC 60947-4-1
    • Range : TeSys
    • [Ui] Rated Insulation Voltage : power circuit 1000 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL
    • Product Compatibility : NSX circuit breaker || LC1D115 || LC1D150
    • Device Short Name : LR9D