TeSys Deca Manual Starter and Protector, thermal magnetic circuit protector, rotary handle, 2.5 to 4 A, screw clamp

MANUAL STARTER 600VAC 4AMP IEC

SQDGV2P08 GV2P08 3389110213478
290.45 / EA
http://schema.org/OutOfStock
  • Country of Origin: Thailand
  • Depth: 3.82 in
  • Height: 3.5 in
  • Warranty Length: 18 mth
  • Width: 1.77 in
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2P controls motors with full load currents up to 32 A. The manual starter is three pol
QTY
  • Product Description
  • Features
  • Specifications
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2P controls motors with full load currents up to 32 A. The manual starter is three pol
  • Connections Terminals
    • power circuit screw clamp terminal 2 1-6 mm²solid
    • powe
  • Uimp Rated Impulse Withstand Voltage
    • 6 kV IEC 60947-2
  • Thermal Protection Adjustment Range
    • 2.5-4 A IEC 60947-2
  • Range Of Product
    • TeSys GV2
    • TeSys Deca
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0 kg CO2 eq.
    • 0.028882284663263702
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0.8882217597579712
    • 0.9 kg CO2 eq.
  • Standards
    • EN/IEC 60947-2
    • EN/IEC 60947-4-1
    • UL 60947-4-1
    • CSA C22.2 No 60947-4-1
    • IEC/EN 60335-2-40:Annex JJ
    • IEC/EN 60335-1:Clause 30.2
  • Ue Rated Operational Voltage
    • 690 V AC 50/60 Hz IEC 60947-2
  • Ui Rated Insulation Voltage
    • 690 V AC 50/60 Hz IEC 60947-2
  • Ics Rated Service Short Circuit Breaking Capacity
    • 100 % 230/240 V AC 50/60 Hz IEC 60947-2
    • 100 % 400/415 V AC 50/60 Hz IEC 60947-2
    • 100 % 400/415
  • Ip Degree Of Protection
    • IP20 IEC 60529
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 2 kg CO2 eq.
    • 1.9174178745780381
  • Rated Duty
    • uninterrupted IEC 60947-4-1
  • Electrical Durability
    • 100000 cycles AC-3 415 V In
    • 100000 cycles AC-3e 415 V In
  • Fixing Mode
    • 35 mm symmetrical DIN rail clipped
    • panel screwed with 2 x M4 screws)
  • Mounting Position
    • horizontal
    • vertical
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • Electrician
  • Fire Resistance
    • 960 °C IEC 60695-2-11
  • Add Ons
    • GVAE11
    • GVAN11
    • GVAE1
    • GVAE20
    • GVAD1010
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 7 kg CO2 eq.
    • 6.5845
  • Persona Type Ids
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SC
  • Carbon Footprint Of The Distribution Phase A4
    • 0.03925994933156967
    • 0 kg CO2 eq.
  • Tightening Torque
    • 1.7 N.m screw clamp terminal
  • Ith Conventional Free Air Thermal Current
    • 4 A IEC 60947-2
  • Mechanical Robustness
    • shocks 30 Gn for 11 ms
    • vibrations 5 Gn, 5...150 Hz
  • Network Frequency
    • 50/60 Hz IEC 60947-2
  • Motor Power Kw
    • 1.1-1.1 kW 400/415 V AC 50/60 Hz
    • 1.5-1.5 kW 500 V AC 50/60 Hz
    • 2.2-2.
  • Suitability For Isolation
    • yes IEC 60947-1
  • Utilisation Category
    • category A IEC 60947-2
    • AC-3 IEC 60947-4-1
    • AC-3e IEC 60947-4-1
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Phase Failure Sensitivity
    • yes IEC 60947-4-1
  • Product Certifications
    • CCC
    • UL
    • CSA
    • EAC
    • ATEX
    • LROS (Lloyds register of shipping)
    • BV
    • RINA
    • DNV-GL
    • UKCA
  • Physical Attributes
    • Color : dark grey
  • Complementary Attributes
    • Line Rated Current : 4 A
    • Maximum Operating Rate : 25 cyc/h
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-18
    • Etim 10 : EC000074
    • Html Descr : TeSys GV2 Motor Circuit BreakerTrip Unit Technology: Thermal MagneticPoles Description: 3-PoleMagnetic Tripping Current: 4ARated Operational Voltage: 690VAC 50/60 Hz conforming to IEC 60947-2Connections - Terminals: Screw C
    • Manufacturer : Schneider Electric
    • Baan Price : 751.15
    • Baan Currency : USD
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Manufacturing Carbon Footprint : 1.91741787457804
    • Distribution Carbon Footprint : 3.92599493315697e-02
    • Installation Carbon Footprint : 2.88822846632637e-02
    • Use Carbon Footprint : 6.5845
    • End Of Life Carbon Footprint : 0.888221759757971
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2211002
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant with Exemptions
    • Rohs Eur Conformity Date : 1936
    • Rohs Eur Full Compliance Status : Compliant with Exemptions
    • China Rohs In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Wd Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : GV2P
    • Control Type : rotary handle
    • Device Application : motor protection
    • Device Short Name : GV2P
    • Magnetic Tripping Current : 74-74 A
    • Mechanical Durability : 100000 cycles
    • Network Type : AC
    • Package Weight Lbs : 324.000 g
    • Poles Description : 3P
    • Power Dissipation Per Pole : 2.5 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : motor circuit breaker
    • Range : TeSys Deca
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 9 kg CO2 eq.
    • Trip Unit Technology : thermal-magnetic
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 9.458281868330843
    • Relationshiptype : Compatible relationship
  • General Attributes
    • Product Or Component Type : motor circuit breaker
  • ETIM
    • ETIM 8 : EC000074
    • ETIM 9 : EC000074
  • Environment Attributes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Carbon Footprint : 9.45828186833084
    • Ambient Air Temperature For Operation : -20-60 °C
    • Ambient Air Temperature For Storage : -40-80 °C
    • Circularity Profile : ENVEOLI2211002
    • Climatic Withstand : IACS E10
    • Environmental Disclosure : ENVPEP2211002
    • Eu Rohs Directive : Compliant with Exemptions
    • Operating Altitude : <= 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Thailand
    • Height : 3.5 in
    • Width : 1.77 in
    • Depth : 3.82 in