TeSys Deca Manual Starter and Protector, thermal magnetic circuit protector, rotary handle, 1 to 1.6 A, screw clamp

MANUAL STARTER 1-1.6AMP

SQDGV2P06 GV2P06 3389110213454
300.06 / EA
http://schema.org/OutOfStock
  • Depth: 97 mm
  • Warranty Length: 18 mth
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2P controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by a rotary handle. The Class 10 ambient compensated thermal over current is adjustable from 1 ampere to 1.6 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).
QTY
  • Product Description
  • Features
  • Specifications
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2P controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by a rotary handle. The Class 10 ambient compensated thermal over current is adjustable from 1 ampere to 1.6 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Color : dark grey
  • Complementary Attributes
    • Ics Rated Service Short Circuit Breaking Capacity : 100 % 230/240 V AC 50/60 Hz IEC 60947-2, 100 % 400/415 V AC 50/60 Hz IEC 60947-2, 100 % 440 V AC 50/60 Hz IEC 60947-2, 100 % 500 V AC 50/60 Hz IEC 60947-2, 100 % 690 V AC 50/60 Hz IEC 60947-2
    • Line Rated Current : 1.6 A
    • Maximum Operating Rate : 25 cyc/h
    • Rated Duty : uninterrupted IEC 60947-4-1
    • Ue Rated Operational Voltage : 690 V AC 50/60 Hz IEC 60947-2
    • Ui Rated Insulation Voltage : 690 V AC 50/60 Hz IEC 60947-2
    • Uimp Rated Impulse Withstand Voltage : 6 kV IEC 60947-2
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Control Type : rotary handle
    • Electrical Durability : 100000 cycles AC-3 415 V In, 100000 cycles AC-3e 415 V In
    • Fixing Mode : 35 mm symmetrical DIN rail clipped, panel screwed with 2 x M4 screws)
    • Mechanical Robustness : shocks 30 Gn for 11 ms, vibrations 5 Gn, 5...150 Hz
    • Motor Power Kw : 0.55-0.55 kW 500 V AC 50/60 Hz0.37-0.37 kW 400/415 V AC 50/60 Hz, 0.55-0.55 kW 400/415 V AC 50/60 Hz, 0.37-0.37 kW 500 V AC 50/60 Hz, 0.75-0.75 kW 690 V AC 50/60 Hz
    • Mounting Position : horizontal, vertical
    • Poles Description : 3P
    • Product Or Component Type : motor circuit breaker
    • Range : TeSys Deca
    • Range Of Product : TeSys GV2, TeSys Deca
    • Tightening Torque : 1.7 N.m screw clamp terminal
    • Trip Unit Technology : thermal-magnetic
    • Utilisation Category : category A IEC 60947-2, AC-3 IEC 60947-4-1, AC-3e IEC 60947-4-1
    • Connections Terminals : power circuit: screw clamp terminal 2 cable(s) 1-6 mm² - solid, power circuit: screw clamp terminal 2 cable(s) 1.5-6 mm² - flexible without cable end, power circuit: screw clamp terminal 2 cable(s) 1-4 mm² - flexible with cable end
    • Ics Rated Service Short Circuit Breaking Capacity : 100 % 230/240 V AC 50/60 Hz IEC 60947-2, 100 % 400/415 V AC 50/60 Hz IEC 60947-2, 100 % 440 V AC 50/60 Hz IEC 60947-2, 100 % 500 V AC 50/60 Hz IEC 60947-2, 100 % 690 V AC 50/60 Hz IEC 60947-2
    • Carbon Footprint Of The Distribution Phase A4 : 0.03925994933156967, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.8882217597579712, 0.9 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.028882284663263702
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 1.9174178745780381
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 7 kg CO2 eq., 6.5845
    • Certificate Agency : CCC, UL, CSA, EAC, ATEX, LROS (Lloyds register of shipping), BV, RINA, DNV-GL, UKCA
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-25
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Service Catalog Item : Finished good
    • Use Carbon Footprint : 6.5845
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2211002
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1936
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 3
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : GV2P
    • Device Application : motor protection
    • Device Short Name : GV2P
    • Fire Resistance : 960 °C IEC 60695-2-11
    • Magnetic Tripping Current : 26.2-26.2 A
    • Mechanical Durability : 100000 cycles
    • Network Frequency : 50/60 Hz IEC 60947-2
    • Network Type : AC
    • Phase Failure Sensitivity : yes IEC 60947-4-1
    • Power Dissipation Per Pole : 2.5 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys GV2
    • Returnability : Yes
    • Software Version : v5.9.4
    • Suitability For Isolation : yes IEC 60947-1
    • Sustainable Packaging : Yes
    • Thermal Protection Adjustment Range : 1-1.6 A IEC 60947-2
    • Total Lifecycle Carbon Footprint : 9 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 1.6 A IEC 60947-2
    • Warranty In Months : 18
    • R Thermal Protection Adj Range 3 : 1-1.6 A
    • Pep Code : ENVPEP2211002EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-06-19
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Protect during 20 years the installation against overloads and short-circuits in circuit with assigned voltage 690V AC and rated current 25A. This protection is ensured in accordance with the following parameters:& 10- Number of poles 3p& 10- Rated breaking capacity 4KA
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 98.55
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; FR
    • Recyclability Potential, In % : 51
    • Offer Owner Code : 190788
    • Pn : 1
    • Height Nominal : 89 mm
    • Width Nominal : 45 mm
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 6.5675
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 6.5845
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 1264.4
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 46.502
    • Impacts Related To Land Use/Soil Quality (-) Operational Energy Use [B6] : 0.2099
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 170.68
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 1381.3
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 116.9
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1264.4
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 116.9
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Storage : -40-80 °C, -40-80 °C
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 9.458281868330843
    • Ambient Air Temperature For Operation : -20-60 °C-20-60 °C
    • Circularity Profile : ENVEOLI2211002
    • Climatic Withstand : IACS E10
    • Environmental Disclosure : ENVPEP2211002EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 IEC 60529
    • Operating Altitude : <= 6561.68 ft (2000 m)<= 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2211002EN
    • Pep Verification Date : 2025-06-19
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : motor circuit breaker
    • Range Of Product : TeSys GV2, TeSys Deca
  • ETIM
    • ETIM 8 : EC000074
    • ETIM 9 : EC000074
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil, France, United Kingdom, Thailand, United States
    • Depth : 97 mm