TeSys GB2 thermal magnetic circuit protector, 1 P, 0.5 A, Id = 3.3 A

TESYS GB2 THERMAL MAGNETIC CIR

SQDGB2CS05 GB2CS05 3389110431612
42.69 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys GB circuit breaker, 1 pole (1P), 0.5A/250V, low tripping threshold, for the protection of industrial equipment control circuits. It provides thermal magnetic protection with a magnetic tripping level at 3.3A (6 In) and breaking capacity Icu 50kA@240V. It can also be used for protection of DC loads up to 0.5A/48V DC-13 with a breaking capacity Icu 1.5kA@24V. Compact device (15mm wide), mounting on 35mm DIN-rail, control by toggle lever (start-stop guaranteed for 8000 cycles). Sold in lots of 6 units. It conforms to IEC 60947-1 and IEC 60947-2.
QTY
  • Product Description
  • Features
  • Specifications
TeSys GB circuit breaker, 1 pole (1P), 0.5A/250V, low tripping threshold, for the protection of industrial equipment control circuits. It provides thermal magnetic protection with a magnetic tripping level at 3.3A (6 In) and breaking capacity Icu 50kA@240V. It can also be used for protection of DC loads up to 0.5A/48V DC-13 with a breaking capacity Icu 1.5kA@24V. Compact device (15mm wide), mounting on 35mm DIN-rail, control by toggle lever (start-stop guaranteed for 8000 cycles). Sold in lots of 6 units. It conforms to IEC 60947-1 and IEC 60947-2.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • UE Rated Operational Voltage : 250 V AC 50/60 Hz IEC 60947-2, 48 V DC
    • Line Rated Current : 0.5 A
    • ICS Rated Service Short Circuit Breaking Capacity : 25 % 230/240 V AC 50/60 Hz IEC 60947-2
    • UIMP Rated Impulse Withstand Voltage : 4 kV IEC 60947-2
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Mechanical Robustness : shocks 22 Gn for 20 ms IEC 60068-2-27, vibrations 5 Gn, 5...110 Hz IEC 60068-2-6
    • Utilisation Category : category A IEC 60947-2, DC-12 IEC 60947-5-1, DC-13 IEC 60947-5-1
    • Carbon Footprint Of The Distribution Phase A4 : 0, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.1 kg CO2 eq., 0.1301891440175684
    • Carbon Footprint Of The Installation Phase A5 : 0.003508579804823296, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.3 kg CO2 eq., 0.3415778689707012
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 2 kg CO2 eq., 2.2455345384121927
    • Connections Terminals : connector 1 0.75-6 mm²solid without cable end, connector 2 0.75-4 mm²solid without cable end, connector 1 0.75-4 mm²flexible with cable end, connector 2 0.75-2.5 mm²flexible with cable end
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-13
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • WEEE Applicability : Finished product
    • WEEE Scope : In
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : GB2
    • Device Short Name : GB2
    • Electrical Durability : 8000 cycles
    • Energy Efficiency Optimized : False
    • Fire Resistance : 960 °C IEC 60695-2-1
    • Halogen Free Status : Halogen free plastic parts product
    • Magnetic Tripping Current : 3.3-3.3 A
    • Network Frequency : 50/60 Hz IEC 60947-2
    • Network Type : AC/DC
    • Package Weight Lbs : 52.000 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : circuit breaker
    • Protective Treatment : TC
    • Range : TeSys
    • Returnability : No
    • Sustainable Packaging : Yes
    • Tightening Torque : 1.2 N.m connector
    • Total Lifecycle Carbon Footprint : 3 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • ICS Rated Service Short Circuit Breaking Capacity : 25 % 230/240 V AC 50/60 Hz IEC 60947-2
    • Pep Code : ENVPEP2306023EN
    • Pep Verification Date : 2025-04-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : Protect the installation against overloads and short circuits and protect people and premises at risk of fire or explosion against insulation defects in a circuit with rated voltage 250V (Ue), rated current 2A (In), with 1P+N poles, a rated breaking capacity 15kA (Icn), and, in the Industrial application areas, while protecting them against the penetration of solid objects and liquids (IP20) in accordance with the standard IEC 62262, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 2.7208101312052855
    • 9 MM Pitches : 2
    • Ambient Air Temperature For Operation : -20-60 °C
    • Environmental Disclosure : ENVPEP2306023EN
    • Halogen Content Performance : Halogen free plastic parts product
    • IP Degree Of Protection : IP20 IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2306023EN
    • Pep Verification Date : 2025-04-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : circuit breaker
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months