contactor, TeSys F, 3P(3NO), AC-3, <=440V 265 A, coil 550...600V AC

TESYS F CONTACTOR - 3P (3 NO)

SQDLC1F265X7 LC1F265X7 3389118095335
1334.88 / EA
http://schema.org/OutOfStock
  • Certifications: ABS, BV, CB, CCC, DNV, LROS (Lloyds Register Of Shipping), RINA, RMRoS, UKCA, UL
  • Contact Configuration: 3 NO
  • Depth: 213 mm
  • Height: 203 mm
  • Impedance: 0.3 MOhm - Ith 350 A 50 Hz
  • Net Weight: 7.44 kg
  • Standard: EN 60947-1, EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, JIS C8201-4-1
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 201.5 mm
QTY
  • Specifications
  • Environment
    • Ambient Air Temperature For Operation : -5-55 °C
    • Height : 203 mm
    • Net Weight : 7.44 kg
    • Ambient Air Temperature For Storage : -60-80 °C
    • Protective Treatment : TH
    • Ip Degree Of Protection : IP20 front face with shrouds IEC 60529 || IP20 front face with shrouds VDE 0106
    • Operating Altitude : 9842.52 ft (3000 m) without derating
    • Width : 201.5 mm
    • Depth : 213 mm
    • Permissible Ambient Air Temperature Around The Device : -40-70 °C
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP080208EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : ENVEOLI100418
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Product Certifications : CCC || RINA || CB || BV || RMRoS || UL || DNV || LROS (Lloyds register of shipping) || ABS || UKCA
    • Power Dissipation Per Pole : 37 W AC-1 || 21 W AC-3
    • Average Impedance : 0.3 mOhm - Ith 350 A 50 Hz
    • [Ith] Conventional Free Air Thermal Current : 350 A (at 40 °C)
    • Control Circuit Voltage Limits : operational 0.85...1.1 Uc 40...400 Hz 55 °C) || drop-out 0.15...0.2 Uc 40...400 Hz 55 °C)
    • Standards : EN 60947-1 || IEC 60947-1 || JIS C8201-4-1 || IEC 60947-4-1 || EN 60947-4-1
    • Mounting Support : plate
    • Control Circuit Type : AC 40...400 Hz
    • Rated Breaking Capacity : 2120 A conforming to IEC 60947-4-1
    • Associated Fuse Rating : 315 A aM at <= 440 V || 400 A gG at <= 440 V
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV
    • Inrush Power In Va : 650-650 VA, 40...400 Hz 0.9 20 °C)
    • Connections - Terminals : control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit bar 2 32 x 4 mm || power circuit lugs-ring terminals 1 240-240 mm² || power circuit connector 1 240-240 mm² || power circuit bolted connection
    • Pole Contact Composition : 3 NO
    • Operating Time : 40...65 ms closing || 100...170 ms opening
    • Maximum Operating Rate : 2400 cyc/h 55 °C
    • Mechanical Durability : 10 Mcycles
    • Tightening Torque : control circuit 1.2 N.m || power circuit 35 N.m
    • Compatibility Code : LC1F
    • Hold-In Power Consumption In Va : 10-10 VA, 40...400 Hz 0.9 20 °C)
    • Overvoltage Category : III
    • Motor Power Kw : 132 kW at 380...400 V AC 50/60 Hz (AC-3) || 140 kW at 415 V AC 50/60 Hz (AC-3) || 140 kW at 440 V AC 50/60 Hz (AC-3) || 160 kW at 500 V AC 50/60 Hz (AC-3) || 160 kW at 660...690 V AC 50/60 Hz (AC-3) || 147 kW at 1000 V AC 50/60 Hz (AC-3) || 75 kW at 220...230 V AC 50/60 Hz (AC-3) || 51 kW at 400 V AC 50/60 Hz (AC-4)
    • [Ui] Rated Insulation Voltage : 1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
    • [Icw] Rated Short-Time Withstand Current : 2200 A 40 °C - 10 s || 1230 A 40 °C - 30 s || 950 A 40 °C - 1 min || 620 A 40 °C - 3 min || 480 A 40 °C - 10 min
    • Heat Dissipation : 8-8 W
  • Specifications
    • [Uc] Control Circuit Voltage : 550...600 V AC 40...400 Hz
    • Range Of Product : TeSys F
    • [Ue] Rated Operational Voltage : <= 1000 V AC-1 || <= 690 V AC-3 || <= 690 V AC-4 || <= 460 V DC
    • Contactor Application : motor control || resistive load
    • Product Or Component Type : contactor
    • Range : TeSys
    • Utilisation Category : AC-4 || AC-1 || AC-3
    • [Ie] Rated Operational Current : 350 A (at <40 °C) at <= 440 V AC AC-1 || 265 A (at <55 °C) at <= 440 V AC AC-3
    • Poles Description : 3P
    • Device Short Name : LC1F