SQUARE D

Contactor, TeSys Deca S207,4P(4NO),AC-1 25A , <=440V, 24V DC coil low consumption coil, lugs-ring terminal

TeSys Deca contactor S207,4P(4

SQDLC1DT256BLS207 LC1DT256BLS207 3389118234772
172.55 / EA
http://schema.org/OutOfStock
  • IsSustainable: No
TeSys Deca railway contactor, 4 poles (4NO), for resistive load applications up to 25A/440V AC-1. It is fully compliant with railway standards. It provides a 24V DC coil, 1NO+1NC built-in auxiliary contact, connection by lug-ring terminals. It procures high reliability and durability with operating rates up to 3600 cycles/hour and environment temperature 60°C. It provides IP20 protection on front face confirming to IEC 60529 Multi international standards certified.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca railway contactor, 4 poles (4NO), for resistive load applications up to 25A/440V AC-1. It is fully compliant with railway standards. It provides a 24V DC coil, 1NO+1NC built-in auxiliary contact, connection by lug-ring terminals. It procures high reliability and durability with operating rates up to 3600 cycles/hour and environment temperature 60°C. It provides IP20 protection on front face confirming to IEC 60529 Multi international standards certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : EN/IEC 60947-4-1, EN/IEC 60947-5-1, EN 45545: R22 HL3, EN 45545: R26 HL3, DIN 5510-2
  • Complementary Attributes
    • Control Circuit Voltage Limits : 0.1...0.25 Uc (-40-70 °C):drop-out DC, 0.7...1.25 Uc (-40-70 °C):operational DC
    • IRMS Rated Making Capacity : 250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • ICW Rated Short Time Withstand Current : 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit
    • IE Rated Operational Current : 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • UI Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    • Control Circuit Type : DC low consumption
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 250 A at 440 V for power circuit conforming to IEC 60947
    • UC Control Circuit Voltage : 24 V DC
    • UE Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • UIMP Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Important Information Attributes
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at <= 690 V coordination type 1 for power circuit, 25 A gG at <= 690 V coordination type 2 for power circuit
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 77 ±15 % ms closing, 25 ±20 % ms opening
    • Power Dissipation Per Pole : 1.56 W AC-1, 0.36 W AC-3
    • Range : TeSys, TeSys Deca
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5
    • ICW Rated Short Time Withstand Current : 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit
    • IE Rated Operational Current : 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • ITH Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 25 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.7246427795188933, 0.7 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.9187390216161835, 0.9 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.023978200054154134
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 2.14539456258519
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 23 kg CO2 eq., 23.17743736008029
    • Connections Terminals : control circuit: lugs-ring terminals - external diameter: 8 mm, power circuit: lugs-ring terminals - external diameter: 8 mm
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-08
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Persona Type Ids : OM8
    • Persona Type Names : OEM - Control Panelbuilder
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Average Impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit
    • Coil Technology : with integral suppression device
    • Compatibility Code : LC1D
    • Contact Compatibility : M5
    • Contactor Application : resistive load
    • Device Short Name : LC1D
    • Electrical Durability : 0.8 Mcycles 25 A AC-1 <= 440 V
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V0 conforming to UL 94
    • Hold In Power Consumption In W : 4-4 W 20 °C
    • Inrush Power In W : 4-4 W 20 °C)
    • Package Weight Lbs : 545.0 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 27 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-11
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Product Manager : NANNAN YAN
  • Environment Attributes Main
    • Climatic Withstand : IACS E10, IEC 60947-1 Annex Q category D
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 26.99019192385471
    • Ambient Air Temperature For Operation : -40-70 °C
    • Environmental Disclosure : ENVPEP1501004EN
    • IP Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-11
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca