IEC contactor, TeSys D, nonreversing, 80A resistive, 4 pole, 2 NO and 2 NC, 120VAC 50/60Hz coil, open style

IEC contactor, TeSys D, nonreversing, 80A resistive, 4 pole, 2 NO and 2 NC, 120VAC 50/60Hz coil, open style

SQDLC1D65008G7 LC1D65008G7 785901699453
682.55 / EACH
  • Certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds Register Of Shipping), RINA, UKCA, UL
  • Contact Configuration: 2 NO + 2 NC
  • Depth: 125 mm
  • Height: 127 mm
  • Impedance: 1.5 MOhm - Ith 80 A 50 Hz Power Circuit
  • Net Weight: 1.45 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 85 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 4.92 inches deep. It weighs 3.20 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 4.92 inches deep. It weighs 3.20 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Hold-In Power Consumption In Va : 13-13 VA 60 Hz 0.3 20 °C) || 15-15 VA 50 Hz 0.3 20 °C)
    • Coil Technology : without built-in suppressor module
    • Control Circuit Voltage Limits : 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60 °C operational AC 50 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz
    • Heat Dissipation : 4-5 W 50/60 Hz
    • Inrush Power In Va : 140-140 VA 60 Hz 0.75 20 °C) || 160-160 VA 50 Hz 0.75 20 °C)
  • Power Dissipation Per Pole : 9.6 W AC-1
  • Control Circuit Type : AC 50/60 Hz
  • Irms Rated Making Capacity : 1000 A 440 V power circuit IEC 60947
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • Utilisation Category : AC-1
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Rated Breaking Capacity : 1000 A 440 V power circuit IEC 60947
  • Overvoltage Category : III
  • Contactor Application : resistive load
  • [Uc] Control Circuit Voltage : 120 V AC 50/60 Hz
  • Electrical Durability : 1.4 Mcycles 80 A AC-1 <= 440 V
  • Device Short Name : LC1D
  • [Ith] Conventional Free Air Thermal Current : 80 A 60 °C power circuit
  • [Icw] Rated Short-Time Withstand Current : 520 A 40 °C - 10 s power circuit || 900 A 40 °C - 1 s power circuit || 110 A 40 °C - 10 min power circuit || 260 A 40 °C - 1 min power circuit
  • Mounting Support : rail || plate
  • Protective Cover : without
  • Range : TeSys
  • Connections - Terminals : control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit screw clamp terminals 1 1-35 mm²flexible without cable end || power circuit screw clamp terminals 2 1-25 mm²flexible without cable end || power circuit screw clamp terminals 1 1-35 mm²flexible with cable end || power circuit screw clamp terminals 2 1-25 mm²flexible with cable end || power circuit screw clamp terminals 1 1-35 mm²solid without cable end || power circuit screw clamp terminals 2 1-25 mm²solid without cable end
  • Operating Time : 4...19 ms opening || 12...26 ms closing
  • Mechanical Durability : 6 Mcycles
  • Average Impedance : 1.5 mOhm - Ith 80 A 50 Hz power circuit
  • Product Or Component Type : contactor
  • Product Certifications : CSA || CCC || UL || BV || LROS (Lloyds register of shipping) || DNV || GL || GOST || RINA || UKCA
  • Poles Description : 4P
  • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
  • [Ie] Rated Operational Current : 80 A 60 °C) <= 440 V AC AC-1 power circuit
  • Product Name : TeSys D
  • Associated Fuse Rating : 125 A gG <= 690 V type 1 power circuit || 125 A gG <= 690 V type 2 power circuit
  • Pole Contact Composition : 2 NO + 2 NC
  • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m screw clamp terminals 25-35 mm² hexagonal 4 mm || power circuit 5 N.m screw clamp terminals 1-25 mm² hexagonal 4 mm
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1
  • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
  • Offer Sustainability
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Environmental Disclosure : ENVPEP1503009EN
    • Sustainable Offer Status : Green Premium product
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Circularity Profile : ENVEOLI1503009EN
    • Eu Rohs Directive : Compliant
    • Toxic Heavy Metal Free : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pvc Free : Yes
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Reach Free Of Svhc : Yes
  • Environment
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open10 Gn for 11 ms
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Depth : 125 mm
    • Flame Retardance : V1 conforming to UL 94
    • Net Weight : 1.45 kg
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Pollution Degree : 3
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Protective Treatment : TH IEC 60068-2-30
    • Height : 127 mm
    • Width : 85 mm
    • Ambient Air Temperature For Storage : -60-80 °C