SQUARE D

IEC contactor, TeSys D, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 72VDC coil, open style

TESYS CONTACTOR 600V 115AMP

SQDLC1D115SD LC1D115SD 338911037737
0.00 / EA
  • Certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds Register Of Shipping), RINA, UKCA, UL
  • Contact Configuration: 1 NO + 1 NC
  • Contact Configuration: 3 NO
  • Depth: 136 mm
  • Height: 158 mm
  • Impedance: 0.6 MOhm - Ith 200 A 50 Hz Power Circuit
  • Net Weight: 2.5 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 120 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 72 VDC coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 72 VDC coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Rohs Exemption Information : Yes
    • Circularity Profile : ENVEOLI100405EN
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Environmental Disclosure : ENVPEP060301EN
    • Eu Rohs Directive : Compliant
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Mercury Free : Yes
  • Protective Cover : with
  • Pole Contact Composition : 3 NO
  • Mounting Support : rail || plate
  • Tightening Torque : control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm
  • Motor Power Kw : 30 kW 220...230 V AC 50/60 Hz AC-3) || 55 kW 380...400 V AC 50/60 Hz AC-3) || 59 kW 415...440 V AC 50/60 Hz AC-3) || 75 kW 500 V AC 50/60 Hz AC-3) || 80 kW 660...690 V AC 50/60 Hz AC-3) || 65 kW 1000 V AC 50/60 Hz AC-3) || 18.5 kW 400 V AC 50/60 Hz AC-4)
  • Range : TeSys
  • Operating Time : 20...35 ms closing || 40...75 ms opening
  • Electrical Durability : 0.8 Mcycles 200 A AC-1 <= 440 V || 0.95 Mcycles 115 A AC-3 <= 440 V
  • Associated Fuse Rating : 250 A gG <= 690 V type 1 power circuit || 200 A gG <= 690 V type 2 power circuit || 10 A gG signalling circuit
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • [Icw] Rated Short-Time Withstand Current : 250 A 40 °C - 10 min power circuit || 550 A 40 °C - 1 min power circuit || 950 A 40 °C - 10 s power circuit || 1100 A 40 °C - 1 s power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
  • Utilisation Category : AC-1 || AC-4 || AC-3
  • Control Circuit Type : DC standard
  • Mechanical Durability : 8 Mcycles
  • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Uc] Control Circuit Voltage : 72 V DC
  • Connections - Terminals : control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible without cable end || control circuit screw clamp terminals 1 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || power circuit connector 1 10-120 mm²flexible without cable end || power circuit connector 2 10-50 mm²flexible without cable end || power circuit connector 1 10-120 mm²flexible with cable end || power circuit connector 2 10-50 mm²flexible with cable end || power circuit connector 1 10-120 mm²solid without cable end || power circuit connector 2 10-50 mm²solid without cable end
  • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
  • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
  • [Ue] Rated Operational Voltage : power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
  • Maximum Operating Rate : 1200 cyc/h 60 °C
  • Rated Breaking Capacity : 1100 A 440 V power circuit IEC 60947
  • Irms Rated Making Capacity : 1260 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1
  • Device Short Name : LC1D
  • Power Dissipation Per Pole : 24 W AC-1 || 7.9 W AC-3
  • Contactor Application : resistive load || motor control
  • Average Impedance : 0.6 mOhm - Ith 200 A 50 Hz power circuit
  • [Ie] Rated Operational Current : 200 A 60 °C) <= 440 V AC AC-1 power circuit || 115 A 60 °C) <= 440 V AC AC-3 power circuit
  • Product Certifications : CSA || GOST || UL || CCC || BV || RINA || DNV || GL || LROS (Lloyds register of shipping) || UKCA
  • Poles Description : 3P
  • Maximum Horse Power Rating : 30 hp 200/208 V at AC 50/60 Hz for 3 phase || 40 hp 230/240 V at AC 50/60 Hz for 3 phase || 75 hp 460/480 V at AC 50/60 Hz for 3 phase || 100 hp 575/600 V at AC 50/60 Hz for 3 phase
  • Product Or Component Type : contactor
  • Overvoltage Category : III
  • Product Name : TeSys D
  • [Ith] Conventional Free Air Thermal Current : 200 A 60 °C power circuit
  • Complementary
    • Control Circuit Voltage Limits : 0.75...1.2 Uc -40-55 °C operational DC || 0.15...0.4 Uc -40-70 °C drop-out DC || 1...1.2 Uc 55-70 °C operational DC
    • Minimum Switching Voltage : 17 V signalling circuit
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Signalling Circuit Frequency : 25...400 Hz
    • Hold-In Power Consumption In W : 2.4-5.1 W 20 °C
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Minimum Switching Current : 5 mA signalling circuit
    • Time Constant : 25 ms
    • Coil Technology : with integral suppression device
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Inrush Power In W : 270-365 W 20 °C)
  • Environment
    • Height : 158 mm
    • Ambient Air Temperature For Storage : -60-80 °C
    • Width : 120 mm
    • Net Weight : 2.5 kg
    • Pollution Degree : 3
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open6 Gn for 11 ms
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Depth : 136 mm
    • Flame Retardance : V1 conforming to UL 94
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Protective Treatment : TH IEC 60068-2-30
    • Ip Degree Of Protection : IP20 front face IEC 60529