SQUARE D

IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 208VAC 50/60Hz coil, open

CONTACTOR 600VAC 115AMP IEC +O

SQDLC1D115LE7 LC1D115LE7 3389110726725
714.16 / EA
http://schema.org/OutOfStock
  • Country of Origin: Czechia
  • Depth: 5.35 in
  • Height: 6.22 in
  • Warranty Length: 18 mth
  • Width: 4.72 in
TeSys Deca contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys Deca contactors are available in 13 contactor ratings for inductive motor applicati
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys Deca contactors are available in 13 contactor ratings for inductive motor applicati
  • Uc Control Circuit Voltage
    • 208 V AC 50/60 Hz
  • Insulation Resistance
    • > 10 MOhm for signalling circuit
  • Heat Dissipation
    • 3-8 W at 50/60 Hz
  • Connections Terminals
    • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
    • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffne
  • Mounting Support
    • rail
    • plate
  • Uimp Rated Impulse Withstand Voltage
    • 8 kV IEC 60947
  • Climatic Withstand
    • IACS E10 exposure to damp heat
    • IEC 60947-1 Annex Q category D exposure to damp heat
  • Power Dissipation Per Pole
    • 24 W AC-1
    • 7.9 W AC-3
    • 7.9 W AC-3e
  • Maximum Operating Rate
    • 2400 cyc/h at 60 °C
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0.3 kg CO2 eq.
    • 0.2654427709841767
  • Non Overlap Time
    • 1.5 ms on de-energisation between NC and NO contact
    • 1.5 ms on energisation between NC and NO contact
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 4.425806016866926
    • 4 kg CO2 eq.
  • Standards
    • CSA C22.2 No 14
    • EN 60947-4-1
    • IEC 60947-4-1
    • IEC 60335-1:Clause 30.2
    • IEC 60335-2-40:Annex JJ
    • UL 60335-2-40:Annex JJ
    • UL 60947-4-1
    • CSA C22.2 No 60947-4-1
    • JIS C8201-4-1
  • Ue Rated Operational Voltage
    • power circuit <= 1000 V AC 25...400 Hz
    • power circuit <= 300 V DC
  • Ui Rated Insulation Voltage
    • power circuit 600 V CSA
    • power circuit 600 V UL
    • power circuit 1000 V IEC 60947-4-1
    • signalli
  • Operating Time
    • 6...20 ms opening
    • 20...50 ms closing
  • Control Circuit Type
    • AC 50/60 Hz
  • Ip Degree Of Protection
    • IP20 front face IEC 60529
  • Minimum Switching Voltage
    • 17 V for signalling circuit
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 22 kg CO2 eq.
    • 22.22881266064238
  • Protective Treatment
    • THIEC 60068-2-30
  • Average Impedance
    • 0.6 mOhm - Ith 200 A 50 Hz for power circuit
  • Electrical Durability
    • 0.8 Mcycles 200 A AC-1 <= 440 V
    • 0.95 Mcycles 115 A AC-3 <= 440 V
    • 0.95 Mcycles 115 A AC-3 <=
  • Maximum Horse Power Rating
    • 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors
    • 40 h
  • Fire Resistance
    • 850 °C IEC 60695-2-1
  • Contactor Application
    • resistive load
    • motor control
  • Flame Retardance
    • V1 conforming to UL 94
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 82 kg CO2 eq.
    • 81.50132194244603
  • Auxiliaries
    • LADN22
    • LADN11
    • LADN20
    • LAD8N11
    • LADT2
    • LADN40
    • LADN31
    • LADN02
    • LADT0
    • LAD8N20
  • Safety Reliability Level
    • B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1
    • B10d = 684932 cycles contactor with nominal load EN/ISO 13849-
  • Carbon Footprint Of The Distribution Phase A4
    • 0.7508929239734572
    • 0.8 kg CO2 eq.
  • Tightening Torque
    • control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm
    • control circuit 1.2 N.
  • Ith Conventional Free Air Thermal Current
    • 200 A (at 60 °C) for power circuit
  • Irms Rated Making Capacity
    • 1260 A at 440 V for power circuit conforming to IEC 60947
    • 140 A AC for signallin
  • Mechanical Robustness
    • vibrations contactor open 2 Gn, 5...300 Hz)
    • vibrations contactor closed 4 Gn, 5...300 Hz)
    • vibrations contactor closed 4
  • Minimum Switching Current
    • 5 mA for signalling circuit
  • Motor Power Kw
    • 30 kW at 220...230 V AC 50/60 Hz (AC-3)
    • 55 kW at 380...400 V AC 50/60 Hz (AC-3)
    • 55 kW at 380..
  • Control Circuit Voltage Limits
    • 0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz
    • 0.8...1.15 Uc (-40-55 °C
  • Utilisation Category
    • AC-1
    • AC-3
    • AC-3e
    • AC-4
  • Ie Rated Operational Current
    • 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • 200 A (at <60 °C) at <= 440 V
  • Icw Rated Short Time Withstand Current
    • 250 A 40 °C - 10 min for power circuit
    • 550 A 40 °C - 1 min for power circuit
    • 550 A 40 °C - 1 min fo
  • Hold In Power Consumption In Va
    • 2-18 VA 60 Hz cos phi 0.3 (at 20 °C)
    • 2-18 VA 50 Hz cos phi 0.3 (at 20 °C)
    • 2-18 VA 50 Hz cos phi 0.3 (at 20
  • Inrush Power In Va
    • 280-350 VA 60 Hz cos phi 0.8 (at 20 °C)
    • 280-350 VA 50 Hz cos phi 0.8 (at 20 °C)
    • 280-350 VA 50
  • Associated Fuse Rating
    • 250 A gG at <= 690 V coordination type 1 for power circuit
    • 250 A gG at <= 690
  • Permissible Ambient Air Temperature Around The Device
    • -40-60 °C
    • 60-70 °C with derating
  • Rated Breaking Capacity
    • 1100 A at 440 V for power circuit conforming to IEC 60947
  • Product Certifications
    • UL
    • CSA
    • CCC
    • UKCA
    • CE
    • EAC
    • Marine
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Manufacturing Carbon Footprint : 22.2288126606424
    • Distribution Carbon Footprint : 0.750892923973457
    • Installation Carbon Footprint : 0.265442770984177
    • Use Carbon Footprint : 81.501321942446
    • End Of Life Carbon Footprint : 4.42580601686693
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI100405EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS Eur In Scope : Yes
    • ROHS Eur Status : Compliant with Exemptions
    • ROHS Eur Conformity Date : 1904
    • ROHS Eur Full Compliance Status : Compliant with Exemptions
    • ROHS Eur Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Compatibility Code : LC1D
    • Contact Compatibility : M13
    • Device Short Name : LC1D
    • Mechanical Durability : 8 Mcycles
    • Overvoltage Category : III
    • Package Weight Lbs : 2.543 kg
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 109 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 109.17227631491296
    • Relationshiptype : Compatible relationship
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS Url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=612704&lang=en-us
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 109.172276314913
    • Circularity Profile : ENVEOLI100405EN
    • Environmental Disclosure : ENVPEP060301EN
    • Eu Rohs Directive : Compliant with Exemptions
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Czechia
    • Height : 6.22 in
    • Width : 4.72 in
    • Depth : 5.35 in