IEC contactor, TeSys D, nonreversing, 115A, 75HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style

IEC contactor, TeSys D, nonreversing, 115A, 75HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style

SQDLC1D1156F7 LC1D1156F7 785901997146
523.95 / EACH
  • Certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds Register Of Shipping), RINA, UKCA, UL
  • Contact Configuration: 1 NO + 1 NC
  • Contact Configuration: 3 NO
  • Depth: 136 mm
  • Height: 158 mm
  • Impedance: 0.6 MOhm - Ith 200 A 50 Hz Power Circuit
  • Net Weight: 2.5 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 120 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Environment
    • Maximum Width : 120 mm
    • Flame Retardance : V1 conforming to UL 94
    • Net Weight : 2.5 kg
    • Ambient Air Temperature For Storage : -60-80 °C
    • Pollution Degree : 3
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Maximum Depth : 136 mm
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open6 Gn for 11 ms
    • Maximum Height : 158 mm
    • Protective Treatment : TH IEC 60068-2-30
  • Contractual warranty
    • Warranty : 18 months
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Poles Description : 3P
  • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
  • [Icw] Rated Short-Time Withstand Current : 250 A 40 °C - 10 min power circuit || 550 A 40 °C - 1 min power circuit || 950 A 40 °C - 10 s power circuit || 1100 A 40 °C - 1 s power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
  • Rated Breaking Capacity : 1100 A 440 V power circuit IEC 60947
  • [Uc] Control Circuit Voltage : 110 V AC 50/60 Hz
  • [Ue] Rated Operational Voltage : power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
  • Mounting Support : plate || rail
  • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
  • Irms Rated Making Capacity : 1260 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1
  • Associated Fuse Rating : 250 A gG <= 690 V type 1 power circuit || 200 A gG <= 690 V type 2 power circuit || 10 A gG signalling circuit
  • Product Name : TeSys D
  • Device Short Name : LC1D
  • Pole Contact Composition : 3 NO
  • Average Impedance : 0.6 mOhm - Ith 200 A 50 Hz power circuit
  • [Ie] Rated Operational Current : 200 A 60 °C) <= 440 V AC AC-1 power circuit || 115 A 60 °C) <= 440 V AC AC-3 power circuit
  • Maximum Operating Rate : 2400 cyc/h 60 °C
  • Mechanical Durability : 8 Mcycles
  • Tightening Torque : control circuit 1.2 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.2 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 12 N.m lugs-ring terminals hexagonal 13 mm M8 || power circuit 12 N.m bars hexagonal 13 mm M8
  • Range : TeSys
  • Electrical Durability : 0.8 Mcycles 200 A AC-1 <= 440 V || 0.95 Mcycles 115 A AC-3 <= 440 V
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
  • Product Or Component Type : contactor
  • Contactor Application : motor control || resistive load
  • Utilisation Category : AC-3 || AC-1 || AC-4
  • Product Certifications : CCC || RINA || GOST || BV || UL || DNV || LROS (Lloyds register of shipping) || CSA || GL || UKCA
  • [Ith] Conventional Free Air Thermal Current : 200 A 60 °C power circuit
  • Motor Power Kw : 30 kW 220...230 V AC 50/60 Hz AC-3) || 55 kW 380...400 V AC 50/60 Hz AC-3) || 59 kW 415...440 V AC 50/60 Hz AC-3) || 75 kW 500 V AC 50/60 Hz AC-3) || 80 kW 660...690 V AC 50/60 Hz AC-3) || 65 kW 1000 V AC 50/60 Hz AC-3) || 18.5 kW 400 V AC 50/60 Hz AC-4)
  • Protective Cover : with
  • Overvoltage Category : III
  • Maximum Horse Power Rating : 30 hp 200/208 V at AC 50/60 Hz for 3 phase || 40 hp 230/240 V at AC 50/60 Hz for 3 phase || 75 hp 460/480 V at AC 50/60 Hz for 3 phase || 100 hp 575/600 V at AC 50/60 Hz for 3 phase
  • Power Dissipation Per Pole : 24 W AC-1 || 7.9 W AC-3
  • Control Circuit Type : AC 50/60 Hz
  • Operating Time : 6...20 ms opening || 20...50 ms closing
  • Connections - Terminals : control circuit lugs-ring terminals 8 mm) || power circuit lugs-ring terminals 25 mm) || power circuit bars 1 5 x 25 mm
  • Complementary
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Hold-In Power Consumption In Va : 2-18 VA 60 Hz 0.3 20 °C) || 2-18 VA 50 Hz 0.3 20 °C)
    • Minimum Switching Voltage : 17 V signalling circuit
    • Heat Dissipation : 3-8 W 50/60 Hz
    • Signalling Circuit Frequency : 25...400 Hz
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Control Circuit Voltage Limits : 0.3...0.5 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55 °C operational AC 50/60 Hz || 1...1.15 Uc 55-70 °C operational AC 50/60 Hz
    • Minimum Switching Current : 5 mA signalling circuit
    • Inrush Power In Va : 280-350 VA 60 Hz 0.8 20 °C) || 280-350 VA 50 Hz 0.8 20 °C)
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
  • Offer Sustainability
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Circularity Profile : ENVEOLI100405EN
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP060301EN
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Rohs Exemption Information : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Eu Rohs Directive : Compliant
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.