IEC contactor, TeSys D Green, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 100/250VAC/VDC coil

TESYS D CTR 50A 100-250VAC/DC

SQDLC1D50AKUE LC1D50AKUE 785901001706
129.79 / EA
  • Certifications: CCC, CSA, DNV-GL, EAC, KC, LROS (Lloyds Register Of Shipping), UKCA, UL
  • Contact Configuration: 1 NO + 1 NC, 3 NO
  • Depth: 120 mm
  • Height: 122 mm
  • Impedance: 1.5 MOhm - Ith 80 A 50 Hz Power Circuit
  • Net Weight: 0.997 kg
  • Standard: CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 55 mm
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Environment
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Net Weight : 0.997 kg
    • Color : Gray SE GREY 6) || Green SE GREEN 2)
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Width : 55 mm
    • Pollution Degree : 3
    • Flame Retardance : V1 conforming to UL 94
    • Ambient Air Temperature For Storage : -60-80 °C
    • Protective Treatment : TH IEC 60068-2-30
    • Height : 122 mm
    • Depth : 120 mm
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
  • Power Dissipation Per Pole : 9.6 W AC-1 || 3.7 W AC-3 || 3.7 W AC-3e
  • Connections - Terminals : control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid || power circuit EverLink BTR screw connectors 1 1-35 mm²flexible without cable end || power circuit EverLink BTR screw connectors 1 1-35 mm²flexible with cable end || power circuit EverLink BTR screw connectors 1 1-35 mm²solid || power circuit EverLink BTR screw connectors 2 1-25 mm²flexible without cable end || power circuit EverLink BTR screw connectors 2 1-25 mm²flexible with cable end || power circuit EverLink BTR screw connectors 2 1-25 mm²solid
  • Coil Type : AC/DC electronic
  • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
  • [Icw] Rated Short-Time Withstand Current : 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit || 84 A 40 °C - 10 min power circuit || 208 A 40 °C - 1 min power circuit || 400 A 40 °C - 10 s power circuit || 810 A 40 °C - 1 s power circuit
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Product Or Component Type : contactor
  • Pole Contact Composition : 3 NO
  • [Ui] Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1
  • Product Name : TeSys D Green
  • Protective Cover : with
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • Utilisation Category : AC-1 || AC-3 || AC-3e
  • Overvoltage Category : III
  • Irms Rated Making Capacity : 900 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1
  • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 100 A gG <= 690 V type 1 power circuit || 100 A gG <= 690 V type 2 power circuit
  • Mounting Support : rail || plate
  • Electrical Durability : 1.8 Mcycles 42 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V || 1.8 Mcycles 42 A AC-3e <= 440 V
  • Mechanical Durability : 6 Mcycles
  • Range : TeSys
  • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm
  • Maximum Horse Power Rating : 3 hp 115 V at AC 60 Hz for 1 phase || 7.5 hp 230/240 V at AC 60 Hz for 1 phase || 15 hp 200/208 V at AC 60 Hz for 3 phase || 15 hp 230/240 V at AC 60 Hz for 3 phase || 40 hp 460/480 V at AC 60 Hz for 3 phase || 40 hp 575/600 V at AC 60 Hz for 3 phase
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Contactor Application : motor control || resistive load
  • Product Certifications : CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
  • Poles Description : 3P
  • [Ie] Rated Operational Current : 80 A 60 °C) <= 440 V AC-1 power circuit || 50 A 60 °C) <= 440 V AC-3 power circuit || 50 A 60 °C) <= 440 V AC-3e power circuit
  • Device Short Name : LC1D
  • [Ith] Conventional Free Air Thermal Current : 80 A 60 °C power circuit || 10 A 60 °C signalling circuit
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • Standards : EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
  • [Uc] Control Circuit Voltage : 100...250 V AC 50/60 Hz || 100...250 V DC
  • Average Impedance : 1.5 mOhm - Ith 80 A 50 Hz power circuit
  • Rated Breaking Capacity : 900 A 440 V power circuit IEC 60947
  • Motor Power Kw : 15 kW 220...230 V AC 50 Hz AC-3) || 22 kW 380...400 V AC 50 Hz AC-3) || 25 kW 415 V AC 50 Hz AC-3) || 30 kW 440 V AC 50 Hz AC-3) || 30 kW 500 V AC 50 Hz AC-3) || 33 kW 660...690 V AC 50 Hz AC-3) || 15 kW 220...230 V AC 50 Hz AC-3e) || 22 kW 380...400 V AC 50 Hz AC-3e) || 25 kW 415 V AC 50 Hz AC-3e) || 30 kW 440 V AC 50 Hz AC-3e) || 30 kW 500 V AC 50 Hz AC-3e) || 33 kW 660...690 V AC 50 Hz AC-3e)
  • Operating Time : 55...65 ms closing || 20...120 ms opening >= 17221) || 20...80 ms opening >= 18011)
  • Complementary
    • Heat Dissipation : 1.2-1.2 W 50/60 Hz
    • Minimum Switching Current : 5 mA signalling circuit
    • Inrush Power In Va : 18-18 VA 50/60 Hz 20 °C)
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Hold-In Power Consumption In Va : 1.8-1.8 VA 20 °C) 50/60 Hz
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Inrush Power In W : 14-14 W 20 °C
    • Hold-In Power Consumption In W : 1.2-1.2 W 20 °C
    • Control Circuit Voltage Limits : <= 0.1 Uc -40-70 °C drop-out AC/DC || 0.85...1.1 Uc -40-60 °C operational AC/DC || 1...1.1 Uc 60-70 °C operational AC/DC
    • Minimum Switching Voltage : 17 V signalling circuit
    • Coil Technology : built-in bidirectional peak limiting
    • Signalling Circuit Frequency : 25...400 Hz
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Environmental Disclosure : ENVPEP1607010EN
    • Mercury Free : Yes
    • Rohs Exemption Information : Yes
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Eu Rohs Directive : Compliant
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Sustainable Offer Status : Green Premium product
    • Circularity Profile : ENVEOLI1607010EN