SQUARE D

IEC contactor, TeSys D Green, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60VAC/VDC coil, open

TESYS D CTR, 32A, 24-60VAC/DC

SQDLC1D32BNE LC1D32BNE 785901765004
94.08 / EA
  • Certifications: CCC, CSA, DNV-GL, EAC, KC, LROS (Lloyds Register Of Shipping), UKCA, UL
  • Contact Configuration: 1 NO + 1 NC, 3 NO
  • Depth: 92 mm
  • Height: 85 mm
  • Impedance: 2 MOhm - Ith 50 A 50 Hz Power Circuit
  • Net Weight: 0.438 kg
  • Standard: CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, UL 60947-4-1
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 45 mm
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 32A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 80A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.97 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 32A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 80A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.97 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Pole Contact Composition : 3 NO
  • Poles Description : 3P
  • Contactor Application : motor control || resistive load
  • Overvoltage Category : III
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • Range : TeSys || TeSys Deca
  • Utilisation Category : AC-1 || AC-3 || AC-3e
  • [Ui] Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
  • Electrical Durability : 2.1 Mcycles 29 A AC-3 <= 440 V || 0.9 Mcycles 50 A AC-1 <= 440 V || 2.1 Mcycles 29 A AC-3e <= 440 V
  • Operating Time : 45...55 ms closing || 20...90 ms opening
  • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 63 A gG <= 690 V type 1 power circuit || 63 A gG <= 690 V type 2 power circuit
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • Device Short Name : LC1D
  • [Ith] Conventional Free Air Thermal Current : 10 A 60 °C signalling circuit || 50 A 60 °C power circuit
  • Mounting Support : rail || plate
  • Power Dissipation Per Pole : 2 W AC-3 || 5 W AC-1 || 2 W AC-3e
  • [Ie] Rated Operational Current : 32 A 60 °C) <= 440 V AC-3 power circuit || 50 A 60 °C) <= 440 V AC-1 power circuit || 32 A 60 °C) <= 440 V AC-3e power circuit
  • Average Impedance : 2 mOhm - Ith 50 A 50 Hz power circuit
  • Rated Breaking Capacity : 550 A 440 V power circuit IEC 60947
  • Product Or Component Type : contactor
  • Protective Cover : with
  • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2 M4 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 M3.5
  • Mechanical Durability : 15 Mcycles
  • Product Name : TeSys D Green || TeSys Deca
  • Maximum Horse Power Rating : 2 hp 115 V at AC 60 Hz for 1 phase || 5 hp 230/240 V at AC 60 Hz for 1 phase || 10 hp 200/208 V at AC 60 Hz for 3 phase || 10 hp 230/240 V at AC 60 Hz for 3 phase || 20 hp 460/480 V at AC 60 Hz for 3 phase || 25 hp 575/600 V at AC 60 Hz for 3 phase
  • Standards : EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
  • Connections - Terminals : control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid || power circuit screw clamp terminals 1 2.5-10 mm²flexible without cable end || power circuit screw clamp terminals 2 2.5-10 mm²flexible without cable end || power circuit screw clamp terminals 1 1-10 mm²flexible with cable end || power circuit screw clamp terminals 2 1.5-6 mm²flexible with cable end || power circuit screw clamp terminals 1 1.5-10 mm²solid || power circuit screw clamp terminals 2 2.5-10 mm²solid
  • Coil Type : AC/DC electronic
  • Irms Rated Making Capacity : 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1 || 550 A 440 V power circuit IEC 60947
  • [Icw] Rated Short-Time Withstand Current : 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit || 60 A 40 °C - 10 min power circuit || 138 A 40 °C - 1 min power circuit || 260 A 40 °C - 10 s power circuit || 430 A 40 °C - 1 s power circuit
  • [Uc] Control Circuit Voltage : 24...60 V AC 50/60 Hz || 24...60 V DC
  • Motor Power Kw : 7.5 kW 220...230 V AC 50 Hz AC-3) || 15 kW 380...400 V AC 50 Hz AC-3) || 15 kW 415 V AC 50 Hz AC-3) || 15 kW 440 V AC 50 Hz AC-3) || 18.5 kW 500 V AC 50 Hz AC-3) || 18.5 kW 660...690 V AC 50 Hz AC-3) || 7.5 kW 220...230 V AC 50 Hz AC-3e) || 15 kW 380...400 V AC 50 Hz AC-3e) || 15 kW 415 V AC 50 Hz AC-3e) || 15 kW 440 V AC 50 Hz AC-3e) || 18.5 kW 500 V AC 50 Hz AC-3e) || 18.5 kW 660...690 V AC 50 Hz AC-3e)
  • Product Certifications : CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
  • Environment
    • Ambient Air Temperature For Storage : -60-80 °C
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Depth : 92 mm
    • Flame Retardance : V1 conforming to UL 94
    • Protective Treatment : TH IEC 60068-2-30
    • Width : 45 mm
    • Pollution Degree : 3
    • Color : Gray SE GREY 6) || Green SE GREEN 2)
    • Height : 85 mm
    • Net Weight : 0.438 kg
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Environmental Disclosure : ENVPEP1609002
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • Sustainable Offer Status : Green Premium product
    • Mercury Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Eu Rohs Directive : Compliant
    • Circularity Profile : ENVEOLI1609002EN
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
  • Complementary
    • Hold-In Power Consumption In W : 0.6-0.6 W 20 °C
    • Control Circuit Voltage Limits : <= 0.1 Uc -40-70 °C drop-out AC/DC || 0.85...1.1 Uc -40-60 °C operational AC || 0.8...1.1 Uc -40-60 °C operational DC || 1...1.1 Uc 60-70 °C operational AC/DC
    • Coil Technology : built-in bidirectional peak limiting
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Inrush Power In Va : 15-15 VA 50/60 Hz 20 °C)
    • Signalling Circuit Frequency : 25...400 Hz
    • Inrush Power In W : 14-14 W 20 °C
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Minimum Switching Voltage : 17 V signalling circuit
    • Heat Dissipation : 0.6-0.6 W 50/60 Hz
    • Minimum Switching Current : 5 mA signalling circuit
    • Hold-In Power Consumption In Va : 0.9-0.9 VA 20 °C) 50/60 Hz
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
  • Contractual warranty
    • Warranty : 18 months