SQUARE D

TeSys Deca IEC contactor, 32 A, 3 P, 20 HP at 480 VAC, reversing, 120 VAC 50/60 Hz coil

REVERSING CONTACTOR 575VAC 32A

SQDLC2D32G7 LC2D32G7 3389110391527
590.68 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 92 mm
  • Height: 85 mm
  • IsSustainable: No
  • Net Weight: 0.797 kg
  • Warranty Length: 18 mth
  • Weight: 0.797 kg
  • Width: 90 mm
TeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3 (15kW@400V). They can be used to create motor starters for almost any type of application. It provides 120V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3 (15kW@400V). They can be used to create motor starters for almost any type of application. It provides 120V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Height : 85 mm
    • Climatic Withstand : IACS E10 || IEC 60947-1 Annex Q category D
    • Pollution Degree : 3
    • Net Weight : 0.797 kg
    • Flame Retardance : V1 conforming to UL 94
    • Ambient Air Temperature For Storage : -60-80 °C
    • Protective Treatment : TH IEC 60068-2-30
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Width : 90 mm
    • Depth : 92 mm
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP110229EN
    • Packaging Without Single Use Plastic : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Circularity Profile : ENVEOLI110229EN
    • Take-Back : No
    • Pvc Free : Yes
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 294.4395406527926
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Current : 5 mA for signalling circuit
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz || 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz || 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz || 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
    • Insulation Resistance : > 10 MOhm for signalling circuit
    • Inrush Power In Va : 70-70 VA 60 Hz cos phi 0.75 (at 20 °C) || 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
    • Coil Technology : without built-in suppressor module
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Signalling Circuit Frequency : 25...400 Hz
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Hold-In Power Consumption In Va : 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C) || 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Heat Dissipation : 2-3 W 50/60 Hz
  • Specifications
    • Country of Origin : France
    • Width : 90 mm
    • Height : 85 mm
    • Weight : 0.797 kg
    • Product Certifications : UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA || CB
    • Interlocking Type : mechanical
    • [Uc] Control Circuit Voltage : 120 V AC 50/60 Hz
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
    • Power Dissipation Per Pole : 2 W AC-3 || 5 W AC-1
    • Average Impedance : 2 mOhm - Ith 50 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit || 50 A (at 60 °C) for power circuit
    • Mounting Support : plate || rail
    • Control Circuit Type : AC 50/60 Hz
    • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Contactor Application : motor control || resistive load
    • Rated Breaking Capacity : 550 A at 440 V for power circuit conforming to IEC 60947
    • Product Or Component Type : reversing contactor
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
    • Product Name : TeSys Deca
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Connections - Terminals : control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid || power circuit screw clamp terminals 1 2.5-10 mm²flexible without cable end || power circuit screw clamp terminals 2 2.5-10 mm²flexible without cable end || power circuit screw clamp terminals 1 1-10 mm²flexible with cable end || power circuit screw clamp terminals 2 1.5-6 mm²flexible with cable end || power circuit screw clamp terminals 1 1.5-10 mm²solid || power circuit screw clamp terminals 2 2.5-10 mm²solid
    • Range : TeSys || TeSys Deca
    • Pole Contact Composition : 3 NO
    • Device Presentation : preassembled with reversing power busbar
    • Utilisation Category : AC-3 || AC-1
    • [Ie] Rated Operational Current : 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2
    • Electrical Durability : 1.65 Mcycles 32 A AC-3 <= 440 V || 1.4 Mcycles 50 A AC-1 <= 440 V
    • Mechanical Durability : 15 Mcycles
    • Poles Description : 3P
    • Operating Time : 12...22 ms closing || 4...19 ms opening
    • Overvoltage Category : III
    • Motor Power Kw : 7.5 kW at 220...230 V AC 50 Hz || 15 kW at 380...400 V AC 50 Hz || 15 kW at 415...440 V AC 50 Hz || 18.5 kW at 500 V AC 50 Hz || 18.5 kW at 660...690 V AC 50 Hz
    • Maximum Horse Power Rating : 2 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 7.5 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 20 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp at 575/600 V AC 60 Hz for 3 phase motors
    • [Ui] Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
    • Device Short Name : LC2D
    • [Icw] Rated Short-Time Withstand Current : 60 A 40 °C - 10 min for power circuit || 138 A 40 °C - 1 min for power circuit || 260 A 40 °C - 10 s for power circuit || 430 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit