IEC contactor, TeSys D, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style

IEC contactor, TeSys D, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style

SQDLC1D32G7 LC1D32G7 785901207207
174.70 / EACH
  • Certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds Register Of Shipping), RINA, UL
  • Contact Configuration: 1 NO + 1 NC
  • Country of Origin: Indonesia
  • Depth: 3.62 in, 92 mm
  • Height: 3.35 in, 85 mm
  • Impedance: 2 mOhm - Ith 50 A 50 Hz Power Circuit
  • Operating Cycles: 3600 cyc/h 60 °C
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Voltage: 300 V, 690 V
  • Warranty Length: 18 mth
  • Weight: 0.375 kg, 0.83 lb
  • Width: 1.77 in, 45 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for any type of application. They can be used to create motor starters for almost any type of application. TeSys D contactors offer quick simple setup, while maintaining a compact size. Contactors have both Horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for any type of application. They can be used to create motor starters for almost any type of application. TeSys D contactors offer quick simple setup, while maintaining a compact size. Contactors have both Horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
  • Offer Sustainability
    • Pvc Free : Yes
    • EU RoHs Directive : Compliant
    • Green Premium Status : Green Premium product
    • REACh Free Of SVHC : Yes
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Inrush Power In VA : 70 VA 60 Hz 0.75 68 °F (20 °C)) || 70 VA 50 Hz 0.75 68 °F (20 °C))
    • Heat Dissipation : 2…3 W 50/60 Hz
    • Minimum Switching Current : 5 mA signalling circuit
    • Auxiliary Contacts Type : type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 || Mirror contact 1 NC IEC 60947-4-1
    • Hold-In Power Consumption Va : 7.5 VA 60 Hz 0.3 68 °F (20 °C)) || 7 VA 50 Hz 0.3 68 °F (20 °C))
    • Signalling Circuit Frequency : 25...400 Hz
    • Insulation Resistance : > 10 MOhm for signalling circuit
    • Minimum Switching Voltage : 17 V signalling circuit
    • Coil Technology : Without built-in suppressor module
    • Ctrl Circuit Voltage Limits : 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz || 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz || 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz || 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
  • Ordering And Shipping Details
    • Returnability : Yes
    • Discount Schedule : I12
    • Category : 22354 - CTR,TESYS D,OPEN,9-38A AC
    • Country Of Origin : ID
    • GTIN : 00785901207207
    • Nbr. Of Units In Pkg. : 1
  • Contractual Warranty
    • Warranty : 18 months
  • Environment
    • Ambient Air Temp For Storage : -76…176 °F (-60…80 °C)
    • Height : 3.35 in (85 mm)
    • Product Weight : 0.83 lb(US) (0.375 kg)
    • Protective Treatment : TH IEC 60068-2-30
    • Ambient Air Temp For Op : -40…140 °F (-40…60 °C) || 140…158 °F (60…70 °C) with derating
    • Pollution Degree : 3
    • Mechanical Robustness : Vibrations contactor open2 Gn, 5...300 Hz || Vibrations contactor closed4 Gn, 5...300 Hz || Shocks contactor closed15 Gn for 11 ms || Shocks contactor open8 Gn for 11 ms
    • IP Degree Of Protection : IP20 front face IEC 60529
    • Width : 1.77 in (45 mm)
    • Depth : 3.62 in (92 mm)
    • Fire Resistance : 1562 °F (850 °C) IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
  • Main
    • Electrical Durability : 1.65 Mcycles 32 A AC-3 <= 440 V || 1.4 Mcycles 50 A AC-1 <= 440 V
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Poles Description : 3P
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Power Pole Contact Composition : 3 NO
    • Control Circuit Type : AC at 50/60 Hz
    • Operating Time : 12...22 ms closing || 4...19 ms opening
    • Irms Rated Making Capacity : 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1 || 550 A 440 V power circuit IEC 60947
    • Motor Power kW : 7.5 kW 220...230 V AC 50/60 Hz AC-3) || 15 kW 380...400 V AC 50/60 Hz AC-3) || 15 kW 415...440 V AC 50/60 Hz AC-3) || 18.5 kW 500 V AC 50/60 Hz AC-3) || 18.5 kW 660...690 V AC 50/60 Hz AC-3) || 7.5 kW 400 V AC 50/60 Hz AC-4)
    • Rated Breaking Capacity : 550 A 440 V power circuit IEC 60947
    • Power Dissipation Per Pole : 2 W AC-3 || 5 W AC-1
    • Uc Control Circuit Voltage : 120 V AC 50/60 Hz
    • Product Name : TeSys D
    • Uimp Rated Imp Wstd Voltage : 6 kV IEC 60947
    • Tightening Torque : Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm || Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 || Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm || Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals Philips No 2
    • Device Short Name : LC1D
    • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 63 A gG <= 690 V type 1 power circuit || 63 A gG <= 690 V type 2 power circuit
    • Contactor Application : Resistive load || Motor control
    • Ui Rated Insulation Voltage : Power circuit 690 V IEC 60947-4-1 || Power circuit 600 V CSA || Power circuit 600 V UL || Signalling circuit 690 V IEC 60947-1 || Signalling circuit 600 V CSA || Signalling circuit 600 V UL
    • Icw Rated Short-Time Wstd Crrt : 260 A 104 °F (40 °C) - 10 s power circuit || 430 A 104 °F (40 °C) - 1 s power circuit || 60 A 104 °F (40 °C) - 10 min power circuit || 138 A 104 °F (40 °C) - 1 min power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
    • Product Or Component Type : Contactor
    • Motor Power Hp (Ul / Csa) : 2 hp 115 V at AC 50/60 Hz for 1 phase || 5 hp 230/240 V at AC 50/60 Hz for 1 phase || 7.5 hp 200/208 V at AC 50/60 Hz for 3 phase || 10 hp 230/240 V at AC 50/60 Hz for 3 phase || 20 hp 460/480 V at AC 50/60 Hz for 3 phase || 30 hp 575/600 V at AC 50/60 Hz for 3 phase
    • Ie Rated Operational Current : 32 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit || 50 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
    • Ith Cnvtl Free Air Therm Crrt : 10 A 140 °F (60 °C) signalling circuit || 50 A 140 °F (60 °C) power circuit
    • Ue Rated Operational Voltage : Power circuit: <= 690 V AC 25...400 Hz || Power circuit <= 300 V DC
    • Front Cover : With
    • Range : TeSys
    • Overvoltage Category : III
    • Operating Rate : 3600 cyc/h 60 °C
    • Mechanical Durability : 15 Mcycles
    • Mounting Support : Rail || Plate
    • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
    • Product Certifications : UL || DNV || CCC || LROS (Lloyds register of shipping) || GOST || GL || CSA || BV || RINA
    • Average Impedance : 2 mOhm - Ith 50 A 50 Hz power circuit
    • Connections - Terminals : Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end || Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end || Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end || Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end || Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end || Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end || Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²)flexible without cable end || Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)flexible without cable end || Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²)flexible with cable end || Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²)flexible with cable end || Power circuit screw clamp terminals 1 0.00…0.02 in² (1.5…10 mm²)solid without cable end || Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)solid without cable end
    • Utilisation Category : AC-3 || AC-1 || AC-4