Combination motor starter, TeSys Ultra, self protected, full voltage nonreversing, NEMA size 1

TESYS U FVNR NEMA SZ 1 SELF PR

SQDLUB32NR LUB32NR 3389118367234
568.06 / EA
http://schema.org/OutOfStock
  • Depth: 126 mm
TeSys U motor starters are integrated starters. TeSys U can be configured to fit specific applications. This TeSys U standard power base has 3 poles that are rated 32A at 600V. This power base is rated for 7.5HP at 200-208VAC, 7.5HP at 240VAC, 10HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. Power base is rated NEMA Size 1. Power base has screw clamp terminals which are non-removable. The power base is 6.42 inches tall, 1.77 inches wide and 5.31 inches deep. Power base is UL Listed and CSA Certified.
QTY
  • Product Description
  • Features
  • Specifications
TeSys U motor starters are integrated starters. TeSys U can be configured to fit specific applications. This TeSys U standard power base has 3 poles that are rated 32A at 600V. This power base is rated for 7.5HP at 200-208VAC, 7.5HP at 240VAC, 10HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. Power base is rated NEMA Size 1. Power base has screw clamp terminals which are non-removable. The power base is 6.42 inches tall, 1.77 inches wide and 5.31 inches deep. Power base is UL Listed and CSA Certified.
  • Features
    • DIN-rail mounting and screw fixing
    • Type of control to be acheived: Basic or Advanced
    • Modular, plug & play structure helps you to perform quick maintenance
    • Direct access to detailed information for every motor starter of your installation
    • Advanced motor management system
  • Conformance Attributes
    • Product Certifications : CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
    • Standards : EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
  • Complementary Attributes
    • Maximum Operating Rate : 3600 cyc/h
  • Important Information Attributes
    • Device Application : motor control, motor protection
    • Fire Resistance : 960 °C parts supporting live components IEC 60695-2-12, 650 °C IEC 60695-2-12
    • Fixing Mode : clipped (DIN rail), screw-fixed (plate)
    • Heat Dissipation : 3-3 W control circuit with LUCA, LUCB, LUCC, LUCD, 1.8-1.8 W control circuit with LUCM
    • Operating Time : 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 65 ms closing with LUCM control circuit
    • Resistance To Electrostatic Discharge : 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
    • Resistance To Fast Transients : 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Shock Resistance : 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
    • Tightening Torque : control circuit: 0.8-1.2 N.m flat screwdriver 5 mm, control circuit: 0.8-1.2 N.m Philips no 1 screwdriver 5 mm, power circuit: 1.9-2.5 N.m flat screwdriver 6 mm, power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6 mm, power circuit: 1.9-2.5 N.m pozidriv No 2 screwdriver 6 mm
    • Typical Current Consumption : 220 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 45 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 200 mA 24 V DC I maximum while closing with LUCM, 220 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 25 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 25 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 45 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 75 mA 24 V DC I rms sealed with LUCM, 80 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 90 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
    • Utilisation Category : AC-43, AC-44, AC-41
    • Vibration Resistance : 2 gn 5-300 Hz) power poles open IEC 60068-2-27, 4 gn 5-300 Hz) power poles closed IEC 60068-2-27
    • Ics Rated Service Breaking Capacity2 : 50 kA 230 V, 50 kA 440 V, 10 kA 500 V, 4 kA 690 V
    • Ie Rated Operational Current2 : 28.5 A <= 440 V, 23 A 500 V, 21 A 690 V
    • Uc Control Circuit Voltage2 : 24 V AC 50/60 Hz, 24 V DC, 48...72 V AC 50/60 Hz, 110...240 V AC 50/60 Hz, 110...220 V DC
    • Ui Rated Insulation Voltage2 : 690 V IEC 60947-6-2 3), 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
    • Carbon Footprint Of The Distribution Phase A4 : 0.48402743062940107, 0.5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 2 kg CO2 eq., 2.2152336182217813
    • Carbon Footprint Of The Installation Phase A5 : 0.06871591408843203, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 8 kg CO2 eq., 8.456331740744961
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 18 kg CO2 eq., 18.290275694507795
    • Connections Terminals : control circuit: screw clamp terminals 1 cable(s) 0.34-1.5 mm² flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² rigid, control circuit: screw clamp terminals 2 cable(s) 0.34-1.5 mm² flexible with cable end, power circuit: screw clamp terminals 1 cable(s) 1-10 mm² rigid, power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm² flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
    • Non Dissipating Shock Wave : 2 kV common mode 48...220 V DC IEC 60947-6-2, 1 kV serial mode 24...240 V AC IEC 60947-6-2, 1 kV serial mode 48...220 V DC IEC 60947-6-2, 2 kV common mode 24...240 V AC IEC 60947-6-2
    • Safe Separation Of Circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
    • Connections Terminals3 : control circuit: screw clamp terminals 1 cable(s) 0.34-1.5 mm² flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² rigid, control circuit: screw clamp terminals 2 cable(s) 0.34-1.5 mm² flexible with cable end, control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² flexible without cable end, control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² rigid, power circuit: screw clamp terminals 1 cable(s) 1-10 mm² rigid, power circuit: screw clamp terminals 1 cable(s) 1-6 mm² flexible with cable end, power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm² flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 1-6 mm² flexible with cable end, power circuit: screw clamp terminals 2 cable(s) 1-6 mm² rigid, power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
    • Ics Rated Service Breaking Capacity5 : 50 kA 230 V, 50 kA 440 V, 10 kA 500 V, 4 kA 690 V
    • Ie Rated Operational Current5 : 28.5 A <= 440 V, 23 A 500 V, 21 A 690 V
    • Uc Control Circuit Voltage5 : 24 V AC 50/60 Hz, 24 V DC, 48...72 V AC 50/60 Hz, 48...72 V DC, 110...240 V AC 50/60 Hz, 110...220 V DC
    • Ui Rated Insulation Voltage5 : 690 V IEC 60947-6-2 3), 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Manufacturer : Schneider Electric
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • WEEE Applicability : Finished product
    • WEEE Scope : In
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2406038EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Compatibility Code : LUB
    • Device Short Name : LUB
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Product contains halogen above thresholds
    • Immunity To Microbreaks : 3 ms control circuit
    • Mechanical Durability : 15 Mcycles
    • Network Frequency : 40...60 Hz
    • Package Weight Lbs : 906 g
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : non reversing power base
    • Protective Treatment : TH IEC 60068
    • Range : TeSys
    • Range Of Product : TeSys Ultra
    • Returnability : Yes
    • Suitability For Isolation : yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 30 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current2 : 32 A
    • Ue Rated Operational Voltage2 : 690 V AC power circuit
    • Uimp Rated Impulse Withstand Voltage2 : 6 kVIEC 60947-6-2
    • Medium Desc : Combination motor starter, TeSys Ultra, self protected, full voltage nonreversing, NEMA size 1
    • Stocking Flag : N
    • Product Kit Identifier : N
    • Pep Code : ENVPEP2406038EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-06-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : France, FR
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Immunity To Radioelectric Fields : 10 V IEC 61000-4-6
    • Immunity To Voltage Dips : 70 % / 500 ms IEC 61000-4-11
    • Resistance To Radiated Fields : 10 V/m 3 IEC 61000-4-3
    • Global Commercial Status : Commercialised
    • Product Name : TeSys Ultra
    • Ue Rated Operational Voltage5 : 690 V AC power circuit
    • Uimp Rated Impulse Withstand Voltage5 : 6 kVIEC 60947-6-2
  • Environment Attributes Main
    • Take Back : No, Nej
    • Ambient Air Temperature For Operation : -25-60 °C with LUCM, -25-60 °C with LUCM, -25-70 °C with LUCA, LUCB, LUCC, LUCD, -25-70 °C with LUCA, LUCB, LUCC, LUCD, -25-60 °C with LUCM, -25-60 °C with LUCM, -25-70 °C with LUCA, LUCB, LUCC, LUCD
    • EU ROHS Directive : Compliant , Compliant
    • IP Degree Of Protection : IP20 IEC 60947-1 front panel and wired terminals), IP20 IEC 60947-1 other faces), IP40 IEC 60947-1 front panel outside connection zone)
    • ROHS Exemption Information : Yes
    • Reach Free SHVC : Yes
    • Halogene Performance : Product contains halogen above thresholds
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 29.51458439819237
    • Ambient Air Temperature For Storage : -40-85 °C
    • Circularity Profile : ENVEOLI2406038EN
    • Environmental Disclosure : ENVPEP2406038EN
    • Halogen Content Performance : Product contains halogen above thresholds
    • Nema Size : 1
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2406038EN
    • Pep Verification Date : 2024-06-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : non reversing power base
    • Range Of Product : TeSys Ultra
  • Specifications
    • Depth : 126 mm