expansion module, Modicon MCM, speed monitoring, 2 SinCos encoder, screw

SPEED MONITORING 2 SIN/COS ENC

SQDXPSMCMEN0200SC XPSMCMEN0200SC 3606480748769
785.59 / EA
http://schema.org/OutOfStock
  • Depth: 22.5 mm
This Modicon MCM safe speed monitoring module has 2 Sin/Cos encoder inputs (with RJ45 connectors) and 2 proximity sensor inputs (connection via terminal) and is fitted with captive screw clamp terminals. It is designed to monitor zero speed control, max speed (limited speed), speed range and direction. It has a rated supply voltage of 24V DC. It offers up to four logically selectable limited speed thresholds (freely configurable via SoSafe Configurable software) for each logical intput (axis), and a maximum input frequency of 500kHz (for encoders) and 5kHz for proximity sensors. It completes your safety CPU with safe-speed monitoring function, ideal for cutting machines like band-saw, circular saw and grinding machines. This module figures LEDs on its front face, displaying the status (power supply, reset, internal or external errors, node address, encoder or proximity sensors connection status, speed monitoring status). The safe speed monitoring module is connected to the safety controller via the backplane expansion connector. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. This module can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PL = e conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL 3 conforming to IEC 62061. The modular safety controllers Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe speed monitoring module instals on Omega 35mm DIN rail conforming to EN 50022, and is connected to the safety controller via the backplane expansion connector. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=XPSMCMEN0200SC_3D-Simpl, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001232_3D-CAD
  • Conformance Attributes
    • Product Certifications : RCM, cULus, TÜV
    • Standards : IEC 61508, ISO 13849-1, IEC 61496-1, IEC 61800-5-1, IEC 62061
  • Complementary Attributes
    • Maximum Input Frequency : 5 kHz sensor, 500 kHz encoder SinCos
    • Integrated Connection Type : backplane expansion bus
    • Uimp Rated Impulse Withstand Voltage : 4 kV IEC 61800-5
    • Us Rated Supply Voltage : 24 V - 20...20 % DC
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Cable Cross Section : 0.2-2.5 mm² - AWG 24...AWG 14 flexible without cable end, 0.2-2.5 mm² - AWG 24...AWG 14 solid without cable end, 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, with bezel, 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, without bezel, 0.2-1.5 mm² - AWG 24...AWG 16 flexible without cable end, 0.25-1 mm² - AWG 23...AWG 18 flexible with cable end, without bezel, 0.5-1.5 mm² - AWG 20...AWG 16 flexible with cable end, with double bezel, 0.2-1 mm² - AWG 24...AWG 18 solid without cable end
    • Electrical Connection : 2 connectors RJ45 EIA/TIA-568-A, screw terminal
    • Electromagnetic Compatibility : electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2, electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2, susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
    • Local Signalling : 1 LED green PWR power ON, 1 LED green RUN RUN (status), 1 LED red E IN internal error, 1 LED red E EX external error, 2 LEDs orange ADDR node address, 2 LEDs yellow PROX proximity sensors connection status, 2 LEDs yellow SH speed monitoring status, 2 LEDs yellow ENC encoder connection status
    • Safety Level : can reach category 4 ISO 13849-1, can reach PL = e ISO 13849-1, type 4 IEC 61496-1, SILCL 3 IEC 62061
    • Vibration Resistance : +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1
    • Connections Terminals : 2 captive screw clamp terminals, removable terminal block, 1 captive screw clamp terminals, removable terminal block
    • Medium Desc : expansion module, Modicon MCM, speed monitoring, 2 SinCos encoder, screw
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-25
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Device Short Name : XPSMCM
    • Function Of Module : speed monitoring
    • Insulation : 250 V AC between power supply and housing IEC 61800-5-1
    • Mounting Support : omega 35 mm DIN rail EN 50022
    • Overvoltage Category : II
    • Power Consumption In W : 3 W
    • Power Dissipation In W : 3 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : safe speed monitoring module
    • Quality Labels : CE
    • Range Of Product : Preventa Safety automation
    • Returnability : No
    • Sensor Type : inductive proximity sensor
    • Service Life : 20 year(s)
    • Shock Resistance : 10 gn 16 ms) 1000 shocks on each axis IEC 61496-1
    • Sustainable Packaging : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Height Nominal : 99 mm
    • Width Nominal : 114.5 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -10-55 °C, -10-55 °C
    • Ambient Air Temperature For Storage : -20-85 °C, -20-85 °C
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 enclosure)
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Relative Humidity : 10-95 %
  • General Attributes
    • Product Or Component Type : safe speed monitoring module
    • Range Of Product : Preventa Safety automation
  • ETIM
    • ETIM 8 : EC001449
    • ETIM 9 : EC001449
  • Input Attributes
    • Maximum Input Frequency : 5 kHz sensor, 500 kHz encoder SinCos
    • Discrete Input Voltage : 24 V DC
  • Specifications
    • Depth : 22.5 mm