  • Depth: 41 mm
  • Dielectric Strength: 4 kV
  • Output Voltage: ...660 V
This Harmony SSP solid state panel mount 3-phase relay is rated 50A, is controlled with a 180V to 280V AC input, has a rated load voltage of 48V to 530V AC with random voltage switching, ideal for inductive loads. It has a visual indicator showing the status of its input and a alarm output enabling a quick response to unexpected events. It also has a test button for easy debugging, testing and commissioning. It is also silent and reliable thanks to the absence of moving contacts. 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
This Harmony SSP solid state panel mount 3-phase relay is rated 50A, is controlled with a 180V to 280V AC input, has a rated load voltage of 48V to 530V AC with random voltage switching, ideal for inductive loads. It has a visual indicator showing the status of its input and a alarm output enabling a quick response to unexpected events. It also has a test button for easy debugging, testing and commissioning. It is also silent and reliable thanks to the absence of moving contacts. 0 0 0 0 0 0 0 0 0 0 0 0
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Horse Power Rating : 1.5 hp 40 °C 120 V AC, 3 hp 40 °C 240 V AC, 7.5 hp 40 °C 480 V AC, 10 hp 40 °C 600 V AC
    • Maximum I T For Fusing : 2520 A².s for 10 ms at 50 Hz, 2320 A².s for 8.3 ms at 60 Hz
    • Maximum Voltage Drop : <1.6 V on-state, <1.6 V on-state<1.6 V on-state, <1.6 V on-state
    • Uc Control Circuit Voltage : 90...280 V AC 50/60 Hz, 180...280 V
    • Uimp Rated Impulse Withstand Voltage : 4 kV for input to case, 6 kV for input/output circuit, 6 kV for input/output to case
    • Absolute Maximum Voltage : 1200 V
    • Line Rated Current : 50 A
    • Maximum Leakage Current : 3 mA off-state
    • Maximum Switching Voltage : 9 V AC turn-off
    • Minimum Switching Voltage : 90 V AC turn-on
    • Rated Current : 50 A
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Control Type : without test button
    • Dielectric Strength : 4 kV AC for input/output, 4 kV AC for input or output to case
    • Electromagnetic Compatibility : electrostatic discharge 4 kV criteria B contact discharge conforming to IEC 61000-4-2, electrostatic discharge 8 kV criteria B air discharge conforming to IEC 61000-4-2, conducted RF disturbances 10 V, 0.15...80 MHz criteria A conforming to IEC 61000-4-6, radiated radio-frequency electromagnetic field immunity test 10 V/m, 80 MHz...1 GHz criteria A conforming to IEC 61000-4-3, surge immunity test 1 kV criteria B output ports line to line conforming to IEC 61000-4-5, surge immunity test 2 kV criteria B output ports line to earth conforming to IEC 61000-4-5, surge immunity test 1 kV criteria B input ports line to earth conforming to IEC 61000-4-5, electrical fast transient/burst immunity test 2 kV, 5kHz criteria B output ports conforming to IEC 61000-4-4, immunity to voltage dips 0 %/20 ms criteria B conforming to IEC 61000-4-11, immunity to voltage dips 40 %/200 ms criteria C conforming to IEC 61000-4-11, immunity to voltage dips 70 %/500 ms criteria C conforming to IEC 61000-4-11, immunity to short interruption 0 %/5 s criteria C conforming to IEC 61000-4-11, electrical fast transient/burst immunity test 1 kV, 5kHz criteria B input ports conforming to IEC 61000-4-4, radiated radio-frequency electromagnetic field immunity test 3 V/m, 1.4...6 GHz criteria A conforming to IEC 61000-4-3, radiated emission 30...1000 Mhz environment A conforming to IEC 60947-1, conducted emission 0.15...30 Mhz environment A conforming to IEC 60947-1
    • Insulation Resistance : >= 1000 MOhm at 500 V DC, >= 1000 MOhm at 500 V DC, >= 1000 MOhm at 500 V DC>= 1000 MOhm at 500 V DC, >= 1000 MOhm at 500 V DC, >= 1000 MOhm at 500 V DC
    • Motor Power Kw : 1.1 kW 40-40 °C 120 V AC, 2.2 kW 40-40 °C 240 V AC, 5.5 kW 40-40 °C 480 V AC, 7.5 kW 40-40 °C 600 V AC
    • Mounting Support : panel
    • Product Or Component Type : panel mount relay
    • Provided Equipment : thermal pad
    • Response Time : 20 ms (turn-on), 30 ms (turn-off)
    • Tightening Torque : 1.2 N.m for input, 2.5 N.m for output
    • Connections Terminals : screw terminals 1 x 0.2...1 x 2.5 mm², AWG 24...AWG 14) input, screw terminals 1 x 1.5...1 x 10 mm², AWG 16...AWG 8) output, screw connectors
    • Carbon Footprint Of The Distribution Phase A4 : 0.0353519565, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.1 kg CO2 eq., 0.0589912253
    • Carbon Footprint Of The Installation Phase A5 : 0.002254205, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 1 kg CO2 eq., 1.444659585
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 5 436 kg CO2 eq., 5436.4715929308
    • Control Circuit Voltage : 180...280 V
    • Certificate Agency : CE, CSA, EAC, UL, UKCA
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Weee Scope : Out
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1930
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Cos Phi : 0.5-0.5 (with maximum load)
    • Device Short Name : SSP
    • Dv Dt : 500 V/µs off-state at maximum voltage
    • Flame Retardance : V0 conforming to UL 94
    • Load Current : 0.4-50 A
    • Local Signalling : LED, green input
    • Marking : CE
    • Overvoltage Category : III
    • Phase : 3 phase
    • Product Availability : Stock - Normally stocked in distribution facility
    • Protection Device Type : TVS
    • Range Of Product : Harmony Solid State Relays
    • Returnability : Yes
    • Software Version : EIME v5.6
    • Sustainable Packaging : Yes
    • Thermal Resistance : 0.15 °C/W
    • Total Lifecycle Carbon Footprint : 5 438 kg CO2 eq.
    • Warranty In Months : 18
    • Output Voltage 35 : 42...660 V AC
    • Pep Code : ENVPEP1307070_V2
    • Database Version : 2017-03
    • Pep Verification Date : 2017-05-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : To control a circuit by a low-power signal with complete electrical isolation between control and controlled circuits, or where several circuits must be controlled by one signal during 20 years with a 30% use rate, in compliance with French standards.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unité (unit)
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 11096.257
    • Energy Model - Manufacturing [A1-a3] : Energy model used: Mexico
    • Energy Model - Installation [A5] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - Use [B6] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity mix; AC; < 1kV; EU-27
    • Offer Owner Code : 190786
    • Pn : 1
    • Height Nominal : 74.6 mm
    • Width Nominal : 104 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -40-80 °C, -40-80 °C
    • Ambient Air Temperature For Storage : -40-125 °C, -40-125 °C
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Lead Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 5438.0128499027
    • Environmental Disclosure : ENVPEP1307070_V2
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1307070_V2
    • Pep Verification Date : 2017-05-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : panel mount relay
    • Provided Equipment : thermal pad
    • Phase : 3 phase
    • Range Of Product : Harmony Solid State Relays
  • ETIM
    • ETIM 8 : EC002055
    • ETIM 9 : EC002055
  • Output Attributes
    • Output Switching Mode : random voltage switching, random voltage switching
    • Output Voltage : 42...660 V AC
    • Solid State Output Type : random voltage switching
  • Surge Protection And Filtering Attributes
    • Surge Current : 715 A 20 ms, 750 A 16.6 ms
  • Input Attributes
    • Cos Phi : 0.5-0.5 (with maximum load)
    • Input Current Limits : 7-20 mA
  • Specifications
    • Country of Origin : Brazil, France, Malta, Mexico
    • Depth : 41 mm
  • Overview Attributes
    • Device Presentation : complete product