SQUARE D

Soft starter, Altivar Soft Starter ATS490, 250A, 208 to 690V AC, control supply 110 to 230V AC

Soft starter, Altivar Soft Sta

SQDATS490C25Y ATS490C25Y 3606486948873
4023.91 / EA
http://schema.org/OutOfStock
  • Connection Type: 1 RJ45 For Connecting Modbus Serial, 1 RJ45 For Connecting Modbus TCP/EtherNet/IP
  • Country of Origin: Indonesia
  • Depth: 265 mm
  • Height: 443 mm
  • Net Weight: 19 kg
  • Operating Position: Vertical +/- 10 Degree
  • Weight: 19 kg
  • Width: 206 mm
This soft starter belongs to the Altivar Soft Starter ATS490 range, which is intended to smoothly start and stop asynchronous motors supplied from 208 to 690V. With an operational rated current of 250A in normal duty, it supplies motor from 55 to 250 kW according to mains voltage. With an efficiency of 99.5%, dedicated application functions, and complete monitoring with data reporting, ATS490 enables advanced motor management. Certified cybersecurity, safe Torque Off, and condition monitoring features increase uptime, reduce operational expenditures, and simplify project design. ATS490 provides comprehensive system monitoring, including the motor, application, power and energy with an accuracy greater than 95%. ATS490 has a native Ethernet port for Modbus TCP or EtherNet/IP and a Modbus serial link. Dimensions are 206mm (width), 265mm (depth), 443mm (height) and it weighs 19kg. ATS490 uses plastic with more than 20% bio-based content, and aluminum is ASI-certified. Altivar Soft Starter ATS490 meets the requirements of applications such as pumps, fans, compressors, conveyors, mixers, cutters, grinders, crushers… It conforms to IEC/EN 60947-4-2 and has received CE, cULus, UKCA, RCM, CCC, and DNV certifications. Some accessories are available, like an IP65 remote mounting kit to mount the graphic display terminal on the enclosure door and communication modules to extend the connectivity to other protocols. The packaging uses recycled cardboard and lower single-use plastic. The ATS490 soft starters shall be mounted vertically inside an enclosure. The built-in and innovative features of ATS490 improve competitiveness, operational resilience, and equipment sustainability. ATS490 delivers excellence in mastering applications and costs, even for the most demanding requirements.
QTY
  • Product Description
  • Features
  • Specifications
This soft starter belongs to the Altivar Soft Starter ATS490 range, which is intended to smoothly start and stop asynchronous motors supplied from 208 to 690V. With an operational rated current of 250A in normal duty, it supplies motor from 55 to 250 kW according to mains voltage. With an efficiency of 99.5%, dedicated application functions, and complete monitoring with data reporting, ATS490 enables advanced motor management. Certified cybersecurity, safe Torque Off, and condition monitoring features increase uptime, reduce operational expenditures, and simplify project design. ATS490 provides comprehensive system monitoring, including the motor, application, power and energy with an accuracy greater than 95%. ATS490 has a native Ethernet port for Modbus TCP or EtherNet/IP and a Modbus serial link. Dimensions are 206mm (width), 265mm (depth), 443mm (height) and it weighs 19kg. ATS490 uses plastic with more than 20% bio-based content, and aluminum is ASI-certified. Altivar Soft Starter ATS490 meets the requirements of applications such as pumps, fans, compressors, conveyors, mixers, cutters, grinders, crushers… It conforms to IEC/EN 60947-4-2 and has received CE, cULus, UKCA, RCM, CCC, and DNV certifications. Some accessories are available, like an IP65 remote mounting kit to mount the graphic display terminal on the enclosure door and communication modules to extend the connectivity to other protocols. The packaging uses recycled cardboard and lower single-use plastic. The ATS490 soft starters shall be mounted vertically inside an enclosure. The built-in and innovative features of ATS490 improve competitiveness, operational resilience, and equipment sustainability. ATS490 delivers excellence in mastering applications and costs, even for the most demanding requirements.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Specifications
    • Country of Origin : Indonesia
    • Width : 206 mm
    • Height : 443 mm
    • Weight : 19 kg
    • Product Destination : asynchronous motors
    • [Ue] Rated Operational Voltage : 208...690 V AC - 15...10 %)
    • Product Or Component Type : soft starter
    • Phase : 3 phase
    • Utilisation Category : AC-3A || AC-53A
    • [Ie] Rated Operational Current : normal duty 250 A in line 40 °C)
    • Communication Port Protocol : Modbus serial || Modbus TCP/EtherNet/IP
    • Product Specific Application : process and infrastructures
    • Safety Function : STO (safe torque off): SIL 1 conforming to IEC 61508 || STO (safe torque off): PL c/category 2 conforming to ISO 13849
    • With Safety Function Cybersecurity : true
    • Maximum Horse Power Rating : 75 hp 208 V normal duty || 100 hp 230 V normal duty || 200 hp 460 V normal duty || 250 hp 575 V normal duty || 60 hp 208 V heavy duty || 75 hp 230 V heavy duty || 150 hp 460 V heavy duty || 200 hp 575 V heavy duty
    • Supply Frequency : 50...60 Hz - 20...20 %
    • Safety Level : security level (SL) 1 IEC 62443-4-2
    • Option Card : communication module CANopen daisy chain || communication module CANopen Sub-D || communication module CANopen open style || communication module Profibus DP V1
    • Range Of Product : Altivar Soft Starter ATS490
    • Service Factor : 100
    • With Safety Function Safe Torque Off (Sto) : true
    • Maximum Permanent Current : 210 A at 40 °C heavy duty
    • Motor Power Kw : 75 kW 230 V in the motor supply line normal duty || 132 kW 400 V in the motor supply line normal duty || 132 kW 440 V in the motor supply line normal duty || 160 kW 500 V in the motor supply line normal duty || 160 kW 525 V in the motor supply line normal duty || 220 kW 660 V in the motor supply line normal duty || 250 kW 690 V in the motor supply line normal duty || 55 kW 230 V in the motor supply line heavy duty || 110 kW 400 V in the motor supply line heavy duty || 110 kW 440 V in the motor supply line heavy duty || 132 kW 500 V in the motor supply line heavy duty || 132 kW 525 V in the motor supply line heavy duty || 160 kW 660 V in the motor supply line heavy duty || 200 kW 690 V in the motor supply line heavy duty || 132 kW 230 V to the motor delta terminals normal duty || 220 kW 400 V to the motor delta terminals normal duty || 110 kW 230 V to the motor delta terminals heavy duty || 160 kW 400 V to the motor delta terminals heavy duty
    • Torque Control : true
    • Device Short Name : ATS490
    • Ip Degree Of Protection : IP00
  • Complementary
    • Product Certifications : CE || cULus || UKCA || RCM || CCC || DNV || ATEX
    • Device Connection : in the motor supply line || inside delta
    • Standards : EN/IEC 60947-4-2 || UL 60947-4-2 || IEC 60664-1
    • Discrete Output Type : programmable digital output DQ1 <= 30 V 100 mA || programmable digital output DQ2 <= 30 V 100 mA
    • [Uc] Control Circuit Voltage : 110...230 V AC 50-60 Hz - 15...10 %
    • Maximum Switching Current : relay outputs 2 A / 250 V AC for AC-15 100000 cycles following IEC 60947-5-1 || relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1
    • Display Screen Available : true
    • Net Weight : 19 kg
    • Relay Output Type : relay outputs R1A, R1C NO || relay outputs R2A, R2C NO || relay outputs R3A, R3C NO
    • Analogue Input Number : 1
    • Discrete Output Number : 2
    • Connector Type : 1 RJ45 for connecting Modbus serial || 1 RJ45 for connecting Modbus TCP/EtherNet/IP
    • Method Of Access : slave Modbus serial
    • Integrated Motor Overload Protection : true
    • Discrete Input Number : 5
    • Accuracy Class : class 10E
    • Power Loss Per Device Current Dependent : 64 W
    • Number Of Addresses : 0-247 Modbus serial
    • Apparent Power : 90 VA
    • Material Declaration : true
    • Width : 206 mm
    • Transmission Rate : 4.8…38.4 kbps || 100 BASE TX
    • Depth : 265 mm
    • Discrete Input Logic : digital input DI1 0...< 5 V <= 2 mA > 11 V, >= 5 mA || digital input DI2 0...< 5 V <= 2 mA > 11 V, >= 5 mA || digital input DI3 0...< 5 V <= 2 mA > 11 V, >= 5 mA || digital input DI4 0...< 5 V <= 2 mA > 11 V, >= 5 mA || digital input STO 0...< 5 V <= 2 mA > 11 V, >= 5 mA
    • Analogue Output Type : current output AQ1 : 0...20 mA/4...20 mA , impedance< 500 Ohm || voltage output AQ1 : 0...10 V , impedance> 470 Ohm
    • Output Compatibility : open collector level 1 PLC IEC 65A-68
    • Operating Rate : 10 cyc/h
    • Analogue Input Type : AI1/PTC1 : PTC/PT 100/PT 1000/KTY84 temperature probe || PTC2 : PTC/PT 100/PT 1000/KTY84 temperature probe || PTC3 : PTC/PT 100/PT 1000/KTY84 temperature probe
    • Height : 443 mm
    • Transmission Frame : RTU || TCP/UDP
    • Relay Output Number : 3
    • Data Format : 8 bits, configurable odd, even or no parity 1or 2 stop
    • Marking : CE || cULus || UKCA || RCM || CCC || ATEX
    • Output Current Drift : 150-700 %
    • Internal Bypass : true
    • Communication Port Protocol : Modbus serial || Modbus TCP/EtherNet/IP
    • Overload Current : 400 % Ie for 13 s
    • Power Losses : 3034 W during starting at 40 °C at 400% Ie
    • Input Compatibility : DI1 discrete input level 1 PLC EN/IEC 61131-2 || DI2 discrete input level 1 PLC EN/IEC 61131-2 || DI3 discrete input level 1 PLC EN/IEC 61131-2 || DI4 discrete input level 1 PLC EN/IEC 61131-2 || STO discrete input level 1 PLC EN/IEC 61131-2
    • Function Available : pre-heating || smoke extraction || second motor set || Deceleration with torque control || Braking || boost || Line contactor control || reverse contactor control || anti-jam || jog || borehole pump starting || condition monitoring || power monitoring || cybersecure firmware update
    • Discrete Input Type : DI1) digital input, 4.4 kOhm || DI2) digital input, 4.4 kOhm || DI3) digital input, 4.4 kOhm || DI4) digital input, 4.4 kOhm || STO) digital input, > 1 kOhm
    • Minimum Switching Current : 100 mA 12 V DC relay outputs
    • Analogue Output Number : 1
    • Physical Interface : 2-wire RS 485 || 100-BASE-TX category 5 or industrial Ethernet
    • [In] Rated Current Pwr Loss Specifctn : 250 A
    • On-Load Factor : 50 %
    • Operating Position : vertical +/- 10 degree
    • Power Loss Static Current Independent : 19 W
    • Type Of Polarization : no impedance Modbus serial
    • Protection Type : phase failure mains || thermal protection starter || thermal protection motor || current overload motor || motor underload motor || excessive acceleration time motor || motor phase loss detection motor || protection against line phase inversion mains || external thermal protection motor || protection delta inside wiring starter || short-circuit between motor phase and earth motor
  • Environmental data
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Take-Back : No
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 2688.8307976519354
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP2311026
    • Packaging Without Single Use Plastic : No
    • Scip Number : 56b10439-800c-4445-84eb-664c87bd785d
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI2311026
    • Pvc Free : Yes
  • Environment
    • Maximum Deflection Under Vibratory Load (During Operation) : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load (During Transport) : 1.75 mm at 2...9 Hz
    • [Ui] Rated Insulation Voltage : 690 V
    • Operating Altitude : <= 6561.68 ft (2000 m) without derating || > 2000...4800 m with current derating 1 % per 100 m above 2000 m
    • Environmental Class (During Operation) : class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
    • Maximum Acceleration Under Vibratory Load (During Transport) : 1 gn at 9…200 Hz || 1.5 gn at 200…500 Hz
    • Maximum Acceleration Under Shock Load (During Transport) : 10 gn at 11 ms
    • Maximum Acceleration Under Shock Impact (During Operation) : 15 gn at 11 ms
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV
    • Pollution Degree : level 3
    • Electromagnetic Compatibility : conducted and radiated emissions level A conforming to IEC 60947-4-2 || damped oscillating waves level 3 conforming to IEC 61000-4-18 || electrostatic discharge level 3 conforming to IEC 61000-4-2 || immunity to electrical transients level 4 conforming to IEC 61000-4-4 || immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 || voltage/current impulse level 3 conforming to IEC 61000-4-5 || immunity to conducted interference caused by radio-electrical fields level 3 conforming to EN/IEC 61000-4-6
    • Ambient Air Temperature For Operation : -25-40 °C (without derating) || 40-60 °C (with current derating of 1 % per °C above 40 °C)
    • Maximum Acceleration Under Vibrational Stress (During Operation) : 1 gn at 13…200 Hz
    • Maximum Acceleration Under Vibratory Load (During Storage) : 1 gn at 9…200 Hz || 1.5 gn at 200…500 Hz
    • Ambient Air Temperature For Storage : -40-70 °C
    • Relative Humidity : 5-95 % without condensation or dripping water EN/IEC 60068-2-3
    • Maximum Acceleration Under Shock Load (During Storage) : 10 gn at 11 ms
    • Ambient Air Transport Temperature : -40-70 °C
    • Maximum Deflection Under Vibratory Load (During Storage) : 1.75 mm at 2...9 Hz