Soft starter, Altivar Soft Starter ATS430, 110A, 208 to 600V AC, control supply 110 to 230V AC

Soft starter, Altivar Soft Sta

SQDATS430C11S6 ATS430C11S6 3606486948668
2504.28 / EA
http://schema.org/OutOfStock
  • Connection Type: 1 RJ45, Open Style
  • Depth: 230.2 mm
  • Operating Position: Vertical +/- 10 Degree
This soft starter belongs to the Altivar Soft Starter ATS430 range which is intended to smoothly start and stop asynchronous motors supplied from 208 to 600V. With an operational rated current of 110A, it supplies motor from 30 to 75kW according to mains voltage. With an efficiency rating of 99.5%, torque control, high stress resistance, and complete monitoring, the ATS430 provides the essentials for effectiveness. Altivar Soft Starter ATS430 delivers best in class motor control with its torque control, the original by Schneider Electric. ATS430 provides complete system monitoring, including the motor, application, power and energy with an accuracy greater than 95%. The cybersecurity standards for ATS430 are met by incorporating best practices that help minimize downtime. Dimensions are 160mm (width), 230mm (depth), 289mm (height) and it weighs 6.6kg. ATS430 uses plastic with more than 20% bio-based content, and aluminum is ASI-certified. Altivar Soft Starter ATS430 is designed for applications such as pumps, fans, compressors, conveyors, and mixers. It conforms to IEC/EN 60947-4-2 and has received CE, cULus, UKCA, RCM, and CCC certifications. Some accessories are available, including an IP65 or IP43 remote mounting kit for installing a plain text or graphic display terminal on the enclosure door. The packaging is made from recycled cardboard and incorporates less single-use plastic. The ATS430 soft starters shall be mounted vertically inside an enclosure. The Altivar Soft Starter ATS430 range offers torque control, reliable operation, and simplicity. It also integrates essential features for the future, including cybersecurity best practices and condition monitoring. ATS430 delivers the essentials for effectiveness while lowering the overall equipment costs.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : RJ45, open style (DO, D1, PE, COM), Modbus serial
  • Complementary Attributes
    • Integrated Motor Overload Protection : true
    • Maximum Horse Power Rating : 30 hp 208 V normal duty40 hp 230 V normal duty75 hp 460 V normal duty100 hp 575 V normal duty
    • Maximum Switching Current : relay outputs 2 A / 250 V AC for AC-15 100000 cycles following IEC 60947-5-1relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1
    • Minimum Switching Current : 100 mA 12 V DC relay outputs
  • Important Information Attributes
    • Connector Type : 1 RJ45, open style
    • Display Type : 1 LED green-yellow)status1 LED Red)Warning/Error1 LED Yellow)COM1, 1 LED Yellow)COM2
    • Electromagnetic Compatibility : conducted and radiated emissions level A conforming to IEC 60947-4-2, electrostatic discharge level 3 conforming to IEC 61000-4-2immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3, immunity to electrical transients level 4 conforming to IEC 61000-4-4voltage/current impulse level 3 conforming to IEC 61000-4-5damped oscillating waves level 3 conforming to IEC 61000-4-18immunity to conducted disturbances radio-frequency level 3 conforming to IEC 61000-4-6
    • Function Available : single direction, pre-heating, power monitoring, condition monitoring, user management, ports and services hardening, security event logging, cybersecure firmware update, small motor test
    • Marking : cULus, CE, UKCA, CCC, RCM, EAC, KC
    • Motor Power Kw : 30 kW 230 V in line normal duty55 kW 400 V in line normal duty, 55 kW 440 V in line normal duty75 kW 500 V in line normal duty, 75 kW 525 V in line normal duty
    • Protection Type : phase failure mains, thermal protection mains, thermal protection startercurrent overload motor, motor underload motor, excessive acceleration time motor, motor phase loss detection motor, protection against line phase inversion mains, external thermal protection motor, short-circuit between motor phase and earth motor
    • Transmission Frame : RTU : 1 RJ45, RTU : open style (DO, D1, PE, COM)
    • Utilisation Category : AC-3A, AC-53A
    • Certificate Agency : cULus, CE, UKCA, CCC, RCM, EAC, KC
    • [Ue] Rated Operational Voltage : 208 V 30 hp normal duty230 V 30 kW normal duty, 230 V 40 hp normal duty400 V 55 kW normal duty, 440 V 55 kW normal duty460 V 75 hp normal duty500 V 75 kW normal duty, 525 V 75 kW normal duty575 V 100 hp normal duty, 208...600 V AC - 15...10 %)
    • Environmental Class (During Operation) : class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
    • Maximum Acceleration Under Vibratory Load (During Storage) : 1 gn at 9…200 Hz, 1.5 gn at 200…500 Hz
    • Maximum Acceleration Under Vibratory Load (During Transport) : 1 gn at 9…200 Hz, 1.5 gn at 200…500 Hz
    • Carbon Footprint Of The Distribution Phase [A4] : 1.480987434717716, 1 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 14.0049784175406, 14 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 1 kg CO2 eq., 1.073119681325051
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 164 kg CO2 eq., 164.3886546978562
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 2 693 kg CO2 eq., 2692.825142464157
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Pre Comm Date : 2025-03-26
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : Soft starter - Soft starter
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2301005EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2412
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Product Kit Identifier : N
    • Apparent Power : 70 VA
    • Data Format : 8 bits, odd, even or no parity, 1 or 2 bits to stop for Modbus serial RJ458 bits, configurable odd, even or no parity for Modbus serial open style (DO, D1, PE, COM)
    • Device Connection : in line
    • Device Short Name : ATS430
    • Display Screen Available : true
    • Internal Bypass : true
    • Material Declaration : true
    • Method Of Access : slave Modbus serial
    • Network Frequency : 50-60 Hz
    • Number Of Addresses : 0-247 Modbus serial
    • Operating Position : vertical +/- 10 degree
    • Operating Rate : 10 cyc/h
    • Overload Current : 400 % Ie for 13 s
    • Phase : 3 phase
    • Power Loss Per Device Current Dependent : 18 W
    • Power Loss Static Current Independent : 19 W
    • Power Losses : 904 W during starting at 40 °C at 400% In
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Destination : asynchronous motors
    • Product Or Component Type : soft starter
    • Product Specific Application : standard industrial machines
    • Range Of Product : Altivar Soft Starter ATS430
    • Returnability : Yes
    • Service Factor : 100
    • Software Version : v6.1
    • Supply Frequency : 50...60 Hz - 20...20 %
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 2 874 kg CO2 eq.
    • Transmission Rate : 4.8…38.4 kbps for Modbus serial RJ450.3...115.2 kbps for Modbus serial open style (DO, D1, PE, COM)
    • Type Of Polarization : no impedance Modbus serial
    • Voltage Ramp : true
    • Volume Of Cooling Air : 31 m3/h
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • Torque Control : true
    • Pep Code : ENVPEP2301005EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-05-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : referent product
    • Functional-unit Description : The aim of soft starter is to drive an asynchronous motor (squirrel cage) by limitation of the current during acceleration phase with a torque control. It’s based on two phases dimmer with silicon controlled rectifier (thyristor). The rating of softstarter is given by nominal current 110A in the case study which lead to drive several power motor depending of power network voltage ie 230V power motor of 30kW and 500V power motor of 75kW. Calculation of the environmental impacts is based on 20 years of product service lifetime. The usage profile taken into account is 50% uptime in use phase and 50% uptime in stand by phase.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 6570
    • Energy Model - Manufacturing [A1-a3] : Indonesia, ID
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Recyclability Potential, In % : 1
    • Height Nominal : 289 mm
    • Width Nominal : 160 mm
    • [Ie] Rated Operational Current : normal duty 110 A in line 40 °C)
    • [Uc] Control Circuit Voltage : 24 V DC110...230 V AC 50-60 Hz - 15...10 %
    • [Ui] Rated Insulation Voltage : 600 V
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV
    • Maximum Acceleration Under Shock Impact (During Operation) : 15 gn at 11 ms
    • Maximum Acceleration Under Shock Load (During Storage) : 10 gn at 11 ms
    • Maximum Acceleration Under Shock Load (During Transport) : 10 gn at 11 ms
    • Maximum Acceleration Under Vibrational Stress (During Operation) : 1 gn at 13…200 Hz
    • Maximum Deflection Under Vibratory Load (During Operation) : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load (During Storage) : 1.75 mm at 2...9 Hz
    • Maximum Deflection Under Vibratory Load (During Transport) : 1.75 mm at 2...9 Hz
    • On-load Factor : 50 %
    • With Safety Function Safe Brake Management (Sbc/Sbt) : false
    • With Safety Function Safe Direction (Sdi) : false
    • With Safety Function Safe Operating Stop (Sos) : false
    • With Safety Function Safe Position (Sp) : false
    • With Safety Function Safe Speed Monitor (Ssm) : false
    • With Safety Function Safe Stop 1 (Ss1) : false
    • With Safety Function Safe Torque Off (Sto) : false
    • With Safety Function Safely Limited Position (Slp) : false
    • With Safety Function Safely Limited Speed (Sls) : false
    • With Sft Fct Safe Stop 2 (Ss2) : false
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 7.846 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • [In] Rated Current Pwr Loss Specifctn2 : 110 A
    • Customs Code : 8537109170
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -25-40 °C (without derating), -25-40 °C (without derating)-25-40 °C (without derating), -25-40 °C (without derating)40-60 °C (with current derating of 1 % per °C above 40 °C)
    • Ambient Air Temperature For Storage : -40-70 °C, -40-70 °C
    • Ambient Air Transport Temperature : -40-70 °C, -40-70 °C
    • Operating Altitude : <= 6561.68 ft (2000 m) without derating, <= 6561.68 ft (2000 m) without derating, > 2000...4800 m with current derating 1 % per 100 m above 2000 m, > 2000...4800 m with current derating 1 % per 100 m above 2000 m<= 6561.68 ft (2000 m) without derating, <= 6561.68 ft (2000 m) without derating, > 2000...4800 m with current derating 1 % per 100 m above 2000 m, > 2000...4800 m with current derating 1 % per 100 m above 2000 m
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Carbon Footprint : 2873.7728826955968
    • Circularity Profile : ENVEOLI2301005EN
    • Environmental Disclosure : ENVPEP2301005EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20
    • Nema Degree Of Protection : open type
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % without condensation or dripping water EN/IEC 60068-2-3
    • Pep Code : ENVPEP2301005EN
    • Pep Verification Date : 2024-05-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : soft starter
    • Range Of Product : Altivar Soft Starter ATS430
  • ETIM
    • ETIM 8 : EC000640
    • ETIM 9 : EC000640
  • Output Attributes
    • Analogue Output Type : current output AQ1 : 0...20 mA/4...20 mA , impedance< 500 Ohm, voltage output AQ1 : 0...10 V , impedance> 470 Ohm
    • Relay Output Type : relay outputs R1A, R1C NOrelay outputs R1B, R1C NC, relay outputs R2A, R2C NO
    • Analogue Output Number : 1
    • Discrete Output Number : 0
    • Output Current Drift : 150-700 %
    • Relay Output Number : 2
  • Input Attributes
    • Analogue Input Type : PTC1 : PTC temperature probe, PTC2 : PTC temperature probe
    • Discrete Input Logic : digital input STOP 0...< 5 V <= 2 mA > 11 V, >= 5 mA, digital input RUN 0...< 5 V <= 2 mA > 11 V, >= 5 mA, digital input DI3 0...< 5 V <= 2 mA > 11 V, >= 5 mA, digital input DI4 0...< 5 V <= 2 mA > 11 V, >= 5 mA
    • Discrete Input Type : STOP) digital input, 4.4 kOhm, RUN) digital input, 4.4 kOhm, DI3) digital input, 4.4 kOhm, DI4) digital input, 4.4 kOhm
    • Input Compatibility : STOP digital input level 1 PLC EN/IEC 61131-2, RUN digital input level 1 PLC EN/IEC 61131-2, DI3 digital input level 1 PLC EN/IEC 61131-2, DI4 digital input level 1 PLC EN/IEC 61131-2
    • Analogue Input Number : 1
    • Discrete Input Number : 4
  • Specifications
    • Country of Origin : Brazil, France, Indonesia, Philippines, United States
    • Depth : 230.2 mm
  • Batteries & Runtime Attributes
    • Removable Battery : Yes