SQUARE D

smart communication module, Modicon M262, CANopen, 1 SubD9

SmartModuleCANopen-1SubD9

SQDTMSCO1 TMSCO1 3606489604240
444.27 / EA
http://schema.org/OutOfStock
  • Depth: 88.3 mm
This smart communication module for Modicon M262 logic/motion controllers is designed to provide 1 CANopen master access to the controllers. TMSCO1 smart communication module integrates M262 controllers in CANopen architectures, ensures communication with devices. It figures one CANopen port for CANopen master communication and supports up to 63 slaves. Modicon M262 are logic/motion controllers with embedded cloud connectivity, figuring cybersecurity capabilities, supporting monitoring, analytics and predictive maintenance. CANopen link can be configured between 20kbps and 1Mbit/s and supports up to 63 slaves. It is possible to connect one CANopen smart communication modules on a logi/motion controller, the power supply is embedded on the communication bus. It measures 30mm width, 88mm depth, and 100mm height. It weighs 0.150kg. This controller is designed for machinery requiring integrated IIoT connectivity or encrypted communication. Certified with CE, cULus HazLoc, RCM, EAC, Achilles L2, EU RO Mutual, Conform to UL 61010-1/-2-201, CSAC22.2 No. 61010-1/-2-201, ANSI/ISA 12-12-01, EN 61131-2. This smart communication module is compatible with Modicon M262 logic/motion controllers. It is configured by EcoStruxure Machine Expert software. TMSCO1 smart communication module installs on 35mm DIN rail with Clip-on locks. Modicon M262 logic/motion controllers are the IIoT-ready controllers for performance machines. Modicon M262 logic/motion controllers embed Industrial Internet of Things (IIoT) protocols and encryption to provide direct cloud connectivity & digital services.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : CANopen
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Electromagnetic Emission : conducted emissions 120...69 dBµV/m QP power lines)10-150 kHz IEC 55011, conducted emissions 63 dBμV/m QP power lines)1.5-30 MHz IEC 55011, radiated emissions 40 dBµV/m A30-230 kHz IEC 55011, conducted emissions 79...63 dBμV/m QP power lines)150-1500 kHz IEC 55011, radiated emissions 47 dBµV/m A230-1000 MHz IEC 55011
    • Local Signalling : 1 LED (green) for PWR, 1 LED (green/red) for MOD STS, 1 LED (green) for CAN RUN, 1 LED (red) for CAN ERR
    • Mounting Support : top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, plate or panel with fixing kit
    • Number Of Module Per Plc : 1 maximum per logic controller, 1 maximum per motion controller
    • Resistance To Conducted Disturbances : 10 V 0.15...80 MHz IEC 61000-4-4, 3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL), 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
    • Resistance To Electromagnetic Fields : 10 V/m 80 MHz...1 GHz IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3, 1 V/m 2 GHz...3 GHz IEC 61000-4-3
    • Resistance To Electrostatic Discharge : 4 kV on contact IEC 61000-4-2, 8 kV on air IEC 61000-4-2
    • Resistance To Fast Transients : 2 kV IEC 61000-4-4 power lines), 1 kV IEC 61000-4-4 Ethernet line), 1 kV IEC 61000-4-4 serial link), 1 kV IEC 61000-4-4 input), 1 kV IEC 61000-4-4 transistor output)
    • Vibration Resistance : 1 gn 8.4-200 Hz panel mounting3.5 mm 2-8.4 Hz symmetrical rail, 1 gn 8.4-200 Hz symmetrical rail, 3.5 mm 2-8.4 Hz panel mounting
    • Carbon Footprint Of The Distribution Phase A4 : 0.032256, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.19466, 0.2 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0047629
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 4 kg CO2 eq., 3.5825
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 52 kg CO2 eq., 51.503
    • Certificate Agency : CE, cULus, RCM, EAC (pending), Achilles
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Manufacturing Carbon Footprint : 3.5825
    • Use Carbon Footprint : 51.503
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1904005EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1936
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : ADVANCED
    • Function Option : Advanced
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Current Consumption : 50 mA 24 V
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : smart communication module
    • Range Of Product : Modicon M262
    • Returnability : No
    • Services : maximum 63 slave nodes
    • Shock Resistance : 15 gn 11 ms
    • Software Version : EIME v5.8.1
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 55 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 55.317
    • Warranty In Months : 18
    • Pep Code : ENVPEP1904005EN
    • Database Version : 2016-11
    • Pep Verification Date : 2019-04-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
    • Data Source : referent product
    • Functional-unit Description : For adding a CANopen master network Equipped with a 9-way SUB-D connector to the M262 Controllers, at 1.2W 100% of the time for 10 years
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unité (unit)
    • Reference Lifetime, In Y : 10
    • Energy Model - Manufacturing [A1-a3] : Energy model used: Indonesia
    • Energy Model - Installation [A5] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - Use [B6] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity mix; AC; < 1kV; EU-27
    • Recyclability Potential, In % : 35
    • Height Nominal : 100 mm
    • Width Nominal : 30 mm
    • Air Pollution (M3) Total Life Cycle : 2639.5
    • Air Pollution (M3) Manufacturing [A1-a3] : 418.13
    • Air Pollution (M3) Distribution [A4] : 1.3721
    • Air Pollution (M3) Operational Energy Use [B6] : 2216.7
    • Air Pollution (M3) End Of Life [C1-c4] : 3.1402
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Total Life Cycle : 622.11
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 36.629
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 584.6
    • Global Warming (Kg.Equivalent.Co2) Total Life Cycle : 55.317
    • Global Warming (Kg.Equivalent.Co2) Manufacturing [A1-a3] : 3.5825
    • Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6] : 51.503
    • Hazardous Waste Disposed Of (Kg) Total Life Cycle : 3.9198
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 3.4823
    • Materials For Recycling (Kg) Total Life Cycle : 0.1609
    • Net Use Of Fresh Water (M3) Total Life Cycle : 186.76
    • Net Use Of Fresh Water (M3) Operational Energy Use [B6] : 186.74
    • Non-hazardous Waste Disposed Of (Kg) Total Life Cycle : 193.05
    • Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 1.0179
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 192.03
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 947.15
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 48.363
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 897.83
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4] : 0.4362
    • Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle : 1080.6
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 51.02
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 1028.6
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 133.46
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 2.6563
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 130.8
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 3.1229
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 3.1229
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 944.02
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 45.241
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 897.83
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 0.4362
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 1.5795
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 1.5795
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 131.88
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 1.0768
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 130.8
    • Water Pollution (M3) Total Life Cycle : 2574.6
    • Water Pollution (M3) Manufacturing [A1-a3] : 435.53
    • Water Pollution (M3) Distribution [A4] : 5.3044
    • Water Pollution (M3) Operational Energy Use [B6] : 2125.2
    • Water Pollution (M3) End Of Life [C1-c4] : 7.8222
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-60 °C horizontal installation, -20-60 °C horizontal installation, -20-50 °C vertical installation, -20-50 °C vertical installation-20-60 °C horizontal installation, -20-60 °C horizontal installation, -20-50 °C vertical installation
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Relative Humidity : 10-95 %, without condensation in operation), 10-95 %, without condensation in storage)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 55.317
    • Circularity Profile : ENVEOLI1904005EN
    • Environmental Disclosure : ENVPEP1904005EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Storage Altitude : 0-3000 m
    • Pep Code : ENVPEP1904005EN
    • Pep Verification Date : 2019-04-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : smart communication module
    • Range Of Product : Modicon M262
  • ETIM
    • ETIM 8 : EC001423
    • ETIM 9 : EC001423
  • Specifications
    • Country of Origin : Brazil, France, Indonesia, Mexico, Singapore
    • Depth : 88.3 mm