safety module, Harmony XPS, zero speed monitoring with time delay, 48 to 240V AC or DC, screw

SAFETY MODULE, HARMONY SAFETY

SQDXPSUVN31AP XPSUVN31AP 3606482034068
671.00 / EA
http://schema.org/OutOfStock
  • Country of Origin: Philippines
  • Depth: 120 mm
  • Input Voltage: 690 V
This safety relay is designed for zero speed monitoring with delayed access to dangerous area. The safety relay is powered with 48 to 240V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 3 safety inputs, 1 NO output configurable between 0,5s and 60s, and 2solid state diagnostic outputq with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 3 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061 and SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÜV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
QTY
  • Features
  • Specifications
  • Features
    • Designed for zero speed monitoring with delayed access to dangerous area
    • Up to PLe safety level Category 3 conforming to ISO 13849-1
    • Screw removable terminal blocks on 2 rows on both top and bottom sides
    • Implement safety functions
    • Reduce risk to an acceptable level
    • IP40 housing, IP20 terminals
    • DIN-rail and direct wall mounting possibility
    • More than 40 different diagnostic messages without additional fieldbus interface
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : TÜV, cULus
    • Standards : IEC 60947-5-1, IEC 61508-1 functional safety standard, IEC 61508-2 functional safety standard, IEC 61508-3 functional safety standard, IEC 61508-4 functional safety standard, IEC 61508-5 functional safety standard, IEC 61508-6 functional safety standard, IEC 61508-7 functional safety standard, ISO 13849-1 functional safety standard, IEC 62061 functional safety standard
  • Complementary Attributes
    • Minimum Output Current : 10 mA relay output
    • Minimum Output Voltage : 5 V relay output
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Function Of Module : monitoring 3-phase motor, monitoring 3-phase motor with star-delta starting, monitoring 3-phase motor with variable number of poles, monitoring 3-phase motor with variable number of poles and star-delta starting, monitoring dc motor, monitoring servo motor, monitoring 3-phase motor supplied by variable speed drive, monitoring 3-phase motor supplied by servo drive, controlling enegization to open of guard switch type XCSE, XCSLE, XCSLF, XCST
    • Local Signalling : LED green power power ON, LED red error error, LED yellow state status, LED yellow L12 input line comparison, LED yellow L32 input line comparison
    • Safety Level : can reach PL e/category 3 for normally open relay contact ISO 13849-1, can reach SILCL 3 for normally open relay contact IEC 62061, can reach SIL 3 for normally open relay contact IEC 61508
    • Ie Rated Operational Current2 : 5 A AC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A DC-13 for normally open relay contact
    • Ui Rated Insulation Voltage2 : 690 V phase to phase 2)IEC 60947-1, 400 V phase to earth 2)IEC 60947-1
    • Carbon Footprint Of The Distribution Phase A4 : 0.126234907243323, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.6 kg CO2 eq., 0.5946166389962003
    • Carbon Footprint Of The Installation Phase A5 : 0.009724835587097183, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 5 kg CO2 eq., 4.828179975038751
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 81 kg CO2 eq., 80.71103427526762
    • Connections Terminals : removable screw terminal block solid or flexible 0.2...2.5 mm², removable screw terminal block flexible with ferrule 0.25...2.5 mm² single conductor, removable screw terminal block solid or flexible 0.2...1.5 mm² twin conductor, removable screw terminal block flexible with ferrule 2 x 0.25...1 mm² without cable end, with bezel, removable screw terminal block flexible with ferrule 2 x 0.5...1.5 mm² with cable end, with bezel
    • Safety Reliability Data : PFHd = 2.44E-9 1/h IEC 62061, PFHd = 2.44E-9 1/h IEC 61508-1, SFF > 99% IEC 61508-1, MTTFd > 30 years ISO 13849-1, Dcavg = 98.9 % ISO 13849-1, PFHd = 2.44E-9 1/h ISO 13849-1, HFT = 1 IEC 62061, SFF > 99% IEC 62061, HFT = 1 IEC 61508-1, type = B IEC 61508-1
    • Time Delay : 0.1 s, 2 s, 3 s, 5 s, 8 s, 12 s, 20 s, 35 s, 60 s
    • Connections Terminals3 : removable screw terminal block solid or flexible 0.2...2.5 mm², removable screw terminal block flexible with ferrule 0.25...2.5 mm² single conductor, removable screw terminal block solid or flexible 0.2...1.5 mm² twin conductor, removable screw terminal block flexible with ferrule 2 x 0.25...1 mm² without cable end, with bezel, removable screw terminal block flexible with ferrule 2 x 0.5...1.5 mm² with cable end, with bezel
    • Ie Rated Operational Current5 : 5 A AC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A DC-13 for normally open relay contact
    • Ui Rated Insulation Voltage5 : 690 V phase to phase 2)IEC 60947-1, 400 V phase to earth 2)IEC 60947-1
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Pre Comm Date : 2021-05-03
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1811003EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Associated Fuse Rating : 6 A gG relay output IEC 60947-1
    • Mounting Support : 35 mm symmetrical DIN rail
    • Package Weight Lbs : 272.0 g
    • Power Consumption In VA : 5.5 VA
    • Power Consumption In W : 2.5 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : safety module
    • Range Of Product : Harmony Safety Automation
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 86 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current2 : 6 A NO relay output circuit
    • Uimp Rated Impulse Withstand Voltage2 : 4 kV II IEC 60947-1
    • Us Rated Supply Voltage2 : 48...240 V AC/DC - 10...10 %
    • Medium Desc : safety module, Harmony XPS, zero speed monitoring with time delay, 48 to 240V AC or DC, screw
    • Stocking Flag : N
    • Product Kit Identifier : N
    • Pep Code : ENVPEP1811003EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-11-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : To monitor signals from a variety of different sensors/devices for safety-related interruption of safety-related electrical circuits at 100% for 10 years.
    • Functional Unit Unit : Unit
    • Energy Model Manufacturing A1 A3 2 : Indonesia, ID
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; Italy, IT
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; Italy, IT
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; Italy, IT
    • Number Of Additional Circuits : 2 solid state outputs
    • Safety Module Application : for zero speed detection
    • Safety Module Name : XPSUVN
    • Global Commercial Status : Commercialised
    • Ith Conventional Free Air Thermal Current5 : 6 A NO relay output circuit
    • Uimp Rated Impulse Withstand Voltage5 : 4 kV II IEC 60947-1
    • Us Rated Supply Voltage5 : 48...240 V AC/DC - 10...10 %
  • Environment Attributes Main
    • Take Back : No, Nej
    • EU ROHS Directive : Compliant By Exemption , Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP20 terminals)IEC 60529, IP40 housing)IEC 60529, IP54 mounting area)IEC 60529
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 86.269790632133
    • Ambient Air Temperature For Operation : -25-55 °C
    • Ambient Air Temperature For Storage : -40-70 °C
    • Circularity Profile : ENVEOLI1811003EN
    • Environmental Disclosure : ENVPEP1811003EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % non-condensing
    • Pep Code : ENVPEP1811003EN
    • Pep Verification Date : 2024-11-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : safety module
    • Range Of Product : Harmony Safety Automation
  • Output Attributes
    • Output Type : relay, 1 NO, volt-free
    • Minimum Output Current : 10 mA relay output
    • Minimum Output Voltage : 5 V relay output
  • Input Attributes
    • Input Detection Threshold : 50 mV, 65 mV, 85 mV, 110 mV, 140 mV, 180 mV, 230 mV, 300 mV, 400 mV, 500 mV
    • Input Voltage : 690 V
  • Specifications
    • Country of Origin : Philippines