safety module, Harmony XPSU, Cat 4, expansion use with universal range, 24V AC or DC, spring

SAFETY MODULE, HARMONY SAFETY

SQDXPSUEP14AC XPSUEP14AC SQDXPSUEP14AC
0.00 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Depth: 120 mm
  • Height: 100 mm
  • Net Weight: 0.200 kg
  • Weight: 0.200 kg
  • Width: 22.5 mm
This safety relay is designed for extending the number of safety contacts. The safety relay is powered with 24V AC/DC, and equipped with a spring removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds a safety extension bus, 4 NO and 2 single NC safety outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. XPSUEP can be only used with XPSUAF, XPSUAK, XPSUAT, XPSUDN and XPSUS safety modules. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
QTY
  • Product Description
  • Features
  • Specifications
This safety relay is designed for extending the number of safety contacts. The safety relay is powered with 24V AC/DC, and equipped with a spring removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds a safety extension bus, 4 NO and 2 single NC safety outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. XPSUEP can be only used with XPSUAF, XPSUAK, XPSUAT, XPSUDN and XPSUS safety modules. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environmental data
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP1811003EN
    • Packaging Without Single Use Plastic : No
    • Scip Number : 152cf799-1df7-4892-81b4-4c890187f1d1
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Circularity Profile : ENVEOLI1811003EN
    • Take-Back : No
    • Pvc Free : Yes
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 54.45541881984912
  • Complementary
    • Height : 100 mm
    • Mounting Support : 35 mm symmetrical DIN rail
    • Minimum Output Voltage : 12 V relay output
    • Minimum Output Current : 10 mA relay output
    • [Ith] Conventional Free Air Thermal Current : 8 A
    • Associated Fuse Rating : 10 A gG NO relay output circuit IEC 60947-1 || 4 A gG NC relay output circuit IEC 60947-1
    • [Uimp] Rated Impulse Withstand Voltage : 4 kV II IEC 60947-1
    • Net Weight : 0.200 kg
    • Number Of Inputs : 0 extension bus 24 V DC 5
    • Input Compatibility : normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
    • Power Consumption In Va : 3.5 VA 24 V AC 50/60 Hz
    • [Ie] Rated Operational Current : 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
    • Auxiliary Contact Composition : 4 NO redundant || 2 NC single
    • [Ui] Rated Insulation Voltage : 250 V 2)IEC 60947-1
    • Power Consumption In W : 1.5 W 24 V DC
    • Maximum Line Resistance : 60 Ohm
    • Local Signalling : for power ON LED (green) || for error LED (red) || for safety output status LED (yellow)
    • Input Protection Type : internal, electronic
    • Width : 22.5 mm
    • Depth : 120 mm
    • Maximum Response Time On Input Open : 20 ms
  • Specifications
    • Country of Origin : Indonesia
    • Width : 22.5 mm
    • Height : 100 mm
    • Weight : 0.200 kg
    • [Us] Rated Supply Voltage : 24 V AC - 15...10 % || 24 V DC - 20...20 %
    • Range Of Product : Harmony Safety Automation
    • Product Or Component Type : safety module
    • Safety Module Name : XPSUEP
    • Connections - Terminals : removable spring terminal block, 0.2...2.5 mm² solid or flexible || removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
    • Safety Module Application : for extending number of safety contacts
    • Safety Reliability Data : MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 0.97E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 0.97E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 0.97E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type = B IEC 61508-1
    • Electrical Circuit Type : addition to Preventa XPSU base module
    • Function Of Module : safety output extension
    • Safety Level : can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508
  • Environment
    • Product Certifications : TÜV || cULus
    • Ip Degree Of Protection : IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
    • Standards : IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
    • Ambient Air Temperature For Storage : -25-85 °C
    • Relative Humidity : 5-95 % non-condensing