  • Country of Origin: Czechia
  • Depth: 130 mm
  • Height: 127 mm
  • Net Weight: 1.44 kg
  • Warranty Length: 18 mth
  • Weight: 1.44 kg
  • Width: 85 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 120 VAC 60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.17 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 120 VAC 60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.17 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : DNV || LROS (Lloyds register of shipping) || RINA || UL || CCC || CSA || GOST || GL || BV || UKCA
    • Height : 127 mm
    • Standards : EN 60947-5-1 || IEC 60947-4-1 || UL 508 || EN 60947-4-1 || CSA C22.2 No 14 || IEC 60947-5-1
    • Net Weight : 1.44 kg
    • Flame Retardance : V1 conforming to UL 94
    • Protective Treatment : TH 3)IEC 60068
    • Ip Degree Of Protection : IP2X IEC 60529 || IP2X VDE 0106
    • Mechanical Robustness : shocks contactor open 8 Gn for 11 ms) || shocks contactor closed 10 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 3 Gn, 5...300 Hz)
    • Operating Altitude : 9842.52 ft (3000 m) without derating
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Width : 85 mm
    • Depth : 130 mm
    • Permissible Ambient Air Temperature Around The Device : -5-60 °C || -40-70 °C at Uc
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110205EN
    • Packaging Without Single Use Plastic : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Circularity Profile : N/A
    • Take-Back : No
    • Pvc Free : Yes
    • Sustainable Packaging : Yes
    • Global Warming ; Total Life Cycle​ : 83 kg CO2 eq.
    • Eu Rohs Directive : Compliant
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 83.38650715
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
    • Minimum Switching Current : 5 mA for control circuit
    • Power Dissipation Per Pole : 6.4 W AC-1
    • Average Impedance : 1 mOhm - Ith 80 A 50 Hz for power circuit
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for control circuit || 80 A (at 60 °C) for power circuit
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (60-60 °C):drop-out AC 60 Hz || 0.85...1.1 Uc (60-60 °C):operational AC 60 Hz
    • Mounting Support : plate || rail
    • Control Circuit Type : AC 60 Hz standard
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Insulation Resistance : > 10 MOhm for control circuit
    • Rated Breaking Capacity : 1000 A at 440 V for power circuit conforming to IEC 60947
    • Irms Rated Making Capacity : 1000 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for control circuit conforming to IEC 60947-5-1
    • Associated Fuse Rating : 10 A gG for control circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
    • Inrush Power In Va : 140-140 VA cos phi 0.75 (at 20 °C)
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
    • Pole Contact Composition : 4 NO
    • Connections - Terminals : control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminal 1 1-35 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminal 2 1-25 mm² - cable stiffness: solid without cable end
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Operating Time : 12...26 ms closing || 4...19 ms opening
    • Minimum Switching Voltage : 17 V for control circuit
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Tightening Torque : control circuit 1.2 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw clamp terminal flat Ø 6 mm || power circuit 5 N.m screw clamp terminal flat Ø 8 mm || control circuit 1.2 N.m screw clamp terminal pozidriv No 2 || power circuit 5 N.m screw clamp terminal pozidriv No 2
    • Mechanical Durability : 6000000 cycles
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Compatibility Code : LC1D
    • Hold-In Power Consumption In Va : 13-13 VA 50 Hz cos phi 0.3 (at 20 °C) || 15-15 VA 60 Hz cos phi 0.3 (at 20 °C)
    • Overvoltage Category : III
    • Maximum Horse Power Rating : 10 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA || 10 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL || 20 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA || 20 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL || 20 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA || 20 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to UL || 5 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA || 5 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL || 50 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to CSA || 50 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to UL || 50 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to CSA || 50 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to UL
    • [Ui] Rated Insulation Voltage : control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
    • Heat Dissipation : 4-5 W at 50/60 Hz for control circuit
    • Protective Cover : with
  • Specifications
    • Country of Origin : Czechia
    • Width : 85 mm
    • Height : 127 mm
    • Weight : 1.44 kg
    • [Uc] Control Circuit Voltage : 120 V AC 60 Hz
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • Range Of Product : TeSys Deca
    • Contactor Application : resistive load
    • Product Or Component Type : contactor
    • Utilisation Category : AC-1 || AC-3 || AC-3e || AC-4
    • [Ie] Rated Operational Current : 80 A (at <60 °C) AC AC-1 for power circuit
    • Poles Description : 4P
    • Device Short Name : LC1D