IEC contactor, TeSys D, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 240VAC 60Hz coil, open

CONTACTOR 600VAC 50AMP IEC +OP

SQDLC1D50U7 LC1D50U7 3389110427592
442.50 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : IEC 60947-5-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 14, EN 60947-5-1, IEC 60947-4-1
  • Complementary Attributes
    • Control Circuit Type : AC 50/60 Hz, AC 50/60 Hz
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
    • IRMS Rated Making Capacity : 900 A at 440 V for power circuit conforming to IEC 60947, 900 A at 440 V for power circuit conforming to IEC 60947, 900 A at 440 V for power circuit conforming to IEC 60947, 900 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for control circuit conforming to IEC 60947-5-1, 140 A AC for control circuit conforming to IEC 60947-5-1, 140 A AC for control circuit conforming to IEC 60947-5-1, 140 A AC for control circuit conforming to IEC 60947-5-1
    • Maximum Horse Power Rating : 3 hp at 115 V AC 60 Hz for 1 phase motors, 3 hp at 115 V AC 60 Hz for 1 phase motors, 3 hp at 115 V AC 60 Hz for 1 phase motors, 3 hp at 115 V AC 60 Hz for 1 phase motors, 3 hp at 115 V AC 60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors, 15 hp at 200/208 V AC 60 Hz for 3 phase motors, 15 hp at 200/208 V AC 60 Hz for 3 phase motors, 15 hp at 200/208 V AC 60 Hz for 3 phase motors, 15 hp at 200/208 V AC 60 Hz for 3 phase motors, 15 hp at 200/208 V AC 60 Hz for 3 phase motors, 15 hp at 230/240 V AC 60 Hz for 3 phase motors, 15 hp at 230/240 V AC 60 Hz for 3 phase motors, 15 hp at 230/240 V AC 60 Hz for 3 phase motors, 15 hp at 230/240 V AC 60 Hz for 3 phase motors, 15 hp at 230/240 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 575/600 V AC 60 Hz for 3 phase motors, 40 hp at 575/600 V AC 60 Hz for 3 phase motors, 40 hp at 575/600 V AC 60 Hz for 3 phase motors, 40 hp at 575/600 V AC 60 Hz for 3 phase motors, 40 hp at 575/600 V AC 60 Hz for 3 phase motors
    • Maximum Operating Rate : 3600 cyc/h at 60 °C, 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for control circuit, 5 mA for control circuit
    • Minimum Switching Voltage : 17 V for control circuit, 17 V for control circuit
    • Rated Breaking Capacity : 900 A at 440 V for power circuit conforming to IEC 60947, 900 A at 440 V for power circuit conforming to IEC 60947, 900 A at 440 V for power circuit conforming to IEC 60947, 900 A at 440 V for power circuit conforming to IEC 60947
    • IE Rated Operational Current : 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • UC Control Circuit Voltage : 240 V AC 50/60 Hz, 240 V AC 50/60 Hz, 240 V AC 50/60 Hz
    • UE Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz
    • UI Rated Insulation Voltage : control circuit 600 V CSA, control circuit 600 V CSA, control circuit 600 V CSA, control circuit 600 V UL, control circuit 600 V UL, control circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V CSA, power circuit 600 V CSA, power circuit 600 V UL, power circuit 600 V UL, power circuit 600 V UL, control circuit 690 V IEC 60947-1, control circuit 690 V IEC 60947-1, control circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-1
    • UIMP Rated Impulse Withstand Voltage : 8 kV IEC 60947, 8 kV IEC 60947
    • Maximum Motor Phase Current : 50 A
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for control circuit conforming to IEC 60947-5-1, 10 A gG for control circuit conforming to IEC 60947-5-1, 10 A gG for control circuit conforming to IEC 60947-5-1, 10 A gG for control circuit conforming to IEC 60947-5-1, 100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : resistive load, motor control
    • Fire Resistance : 850 °C IEC 60695-2-1, 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94, V1 conforming to UL 94
    • Heat Dissipation : 4-5 W at 50/60 Hz for control circuit, 4-5 W at 50/60 Hz for control circuit, 4-5 W at 50/60 Hz for control circuit
    • Hold In Power Consumption In VA : 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Inrush Power In VA : 140-140 VA cos phi 0.75 (at 20 °C), 140-140 VA cos phi 0.75 (at 20 °C), 140-140 VA cos phi 0.75 (at 20 °C), 160-160 VA cos phi 0.75 (at 20 °C), 160-160 VA cos phi 0.75 (at 20 °C), 160-160 VA cos phi 0.75 (at 20 °C)
    • Insulation Resistance : > 10 MOhm for control circuit, > 10 MOhm for control circuit
    • Mechanical Robustness : shocks contactor opened 10 Gn for 11 ms), shocks contactor opened 10 Gn for 11 ms), shocks contactor opened 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), vibrations contactor opened 2 Gn, 5...300 Hz), vibrations contactor opened 2 Gn, 5...300 Hz), vibrations contactor opened 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz)
    • Motor Power KW : 22 kW at 380...400 V AC 50 Hz (AC-3), 22 kW at 380...400 V AC 50 Hz (AC-3), 22 kW at 380...400 V AC 50 Hz (AC-3), 22 kW at 380...400 V AC 50 Hz (AC-3), 22 kW at 380...400 V AC 50 Hz (AC-3), 25 kW at 415 V AC 50 Hz (AC-3), 25 kW at 415 V AC 50 Hz (AC-3), 25 kW at 415 V AC 50 Hz (AC-3), 25 kW at 415 V AC 50 Hz (AC-3), 25 kW at 415 V AC 50 Hz (AC-3), 30 kW at 440 V AC 50 Hz (AC-3), 30 kW at 440 V AC 50 Hz (AC-3), 30 kW at 440 V AC 50 Hz (AC-3), 30 kW at 440 V AC 50 Hz (AC-3), 30 kW at 440 V AC 50 Hz (AC-3), 30 kW at 500 V AC 50 Hz (AC-3), 30 kW at 500 V AC 50 Hz (AC-3), 30 kW at 500 V AC 50 Hz (AC-3), 30 kW at 500 V AC 50 Hz (AC-3), 30 kW at 500 V AC 50 Hz (AC-3), 33 kW at 660...690 V AC 50 Hz (AC-3), 33 kW at 660...690 V AC 50 Hz (AC-3), 33 kW at 660...690 V AC 50 Hz (AC-3), 33 kW at 660...690 V AC 50 Hz (AC-3), 33 kW at 660...690 V AC 50 Hz (AC-3), 15 kW at 220...230 V AC 50 Hz (AC-3), 15 kW at 220...230 V AC 50 Hz (AC-3), 15 kW at 220...230 V AC 50 Hz (AC-3), 15 kW at 220...230 V AC 50 Hz (AC-3), 15 kW at 220...230 V AC 50 Hz (AC-3), 11 kW at 400 V AC 50 Hz (AC-4), 11 kW at 400 V AC 50 Hz (AC-4), 11 kW at 400 V AC 50 Hz (AC-4), 11 kW at 400 V AC 50 Hz (AC-4), 11 kW at 400 V AC 50 Hz (AC-4), 30 kW at 1000 V AC 50 Hz (AC-3), 30 kW at 1000 V AC 50 Hz (AC-3), 30 kW at 1000 V AC 50 Hz (AC-3), 30 kW at 1000 V AC 50 Hz (AC-3), 30 kW at 1000 V AC 50 Hz (AC-3), 22 kW at 380...400 V AC 50 Hz (AC-3e), 22 kW at 380...400 V AC 50 Hz (AC-3e), 22 kW at 380...400 V AC 50 Hz (AC-3e), 22 kW at 380...400 V AC 50 Hz (AC-3e), 22 kW at 380...400 V AC 50 Hz (AC-3e), 25 kW at 415 V AC 50 Hz (AC-3e), 25 kW at 415 V AC 50 Hz (AC-3e), 25 kW at 415 V AC 50 Hz (AC-3e), 25 kW at 415 V AC 50 Hz (AC-3e), 25 kW at 415 V AC 50 Hz (AC-3e), 30 kW at 440 V AC 50 Hz (AC-3e), 30 kW at 440 V AC 50 Hz (AC-3e), 30 kW at 440 V AC 50 Hz (AC-3e), 30 kW at 440 V AC 50 Hz (AC-3e), 30 kW at 440 V AC 50 Hz (AC-3e), 30 kW at 500 V AC 50 Hz (AC-3e), 30 kW at 500 V AC 50 Hz (AC-3e), 30 kW at 500 V AC 50 Hz (AC-3e), 30 kW at 500 V AC 50 Hz (AC-3e), 30 kW at 500 V AC 50 Hz (AC-3e), 33 kW at 660...690 V AC 50 Hz (AC-3e), 33 kW at 660...690 V AC 50 Hz (AC-3e), 33 kW at 660...690 V AC 50 Hz (AC-3e), 33 kW at 660...690 V AC 50 Hz (AC-3e), 33 kW at 660...690 V AC 50 Hz (AC-3e), 15 kW at 220...230 V AC 50 Hz (AC-3e), 15 kW at 220...230 V AC 50 Hz (AC-3e), 15 kW at 220...230 V AC 50 Hz (AC-3e), 15 kW at 220...230 V AC 50 Hz (AC-3e), 15 kW at 220...230 V AC 50 Hz (AC-3e), 30 kW at 1000 V AC 50 Hz (AC-3e), 30 kW at 1000 V AC 50 Hz (AC-3e), 30 kW at 1000 V AC 50 Hz (AC-3e), 30 kW at 1000 V AC 50 Hz (AC-3e), 30 kW at 1000 V AC 50 Hz (AC-3e)
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contacts, 1.5 ms on de-energisation between NC and NO contacts, 1.5 ms on energisation between NC and NO contacts, 1.5 ms on energisation between NC and NO contacts
    • Operating Time : 4...19 ms opening, 4...19 ms opening, 12...26 ms closing, 12...26 ms closing
    • Power Dissipation Per Pole : 3.7 W AC-3, 3.7 W AC-3, 9.6 W AC-1, 9.6 W AC-1, 3.7 W AC-3e, 3.7 W AC-3e
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminal Philips No 2, control circuit 1.7 N.m screw clamp terminal Philips No 2, control circuit 1.7 N.m screw clamp terminal Philips No 2, control circuit 1.7 N.m screw clamp terminal Philips No 2, power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm, power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm, power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm, power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm, control circuit 1.7 N.m screw clamp terminal pozidriv No 2, control circuit 1.7 N.m screw clamp terminal pozidriv No 2, control circuit 1.7 N.m screw clamp terminal pozidriv No 2, control circuit 1.7 N.m screw clamp terminal pozidriv No 2
    • IE Rated Operational Current : 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • ITH Conventional Free Air Thermal Current : 10 A (at 60 °C) for control circuit, 10 A (at 60 °C) for control circuit, 10 A (at 60 °C) for control circuit, 80 A (at 60 °C) for power circuit, 80 A (at 60 °C) for power circuit, 80 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.10897387411712167, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 2.060780384594516, 2 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.2 kg CO2 eq., 0.1562477980712773
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 6 kg CO2 eq., 5.524000021647814
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 46 kg CO2 eq., 45.50628623188404
    • Connections Terminals : control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end
    • Auxiliaries : LADN22, LADN11, LADN20, LAD8N11, LADT2, LADN40, LADN31, LADN02, LADT0, LAD8N20
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-05-31
    • HTML Description : TeSys D ContactorNumber of Poles: 3-PolesPole Contact Composition: 3 NORated Operational Current: 50AControl Circuit Voltage: 240V AC 50/60 HzNon-Reversing
    • Manufacturer : Schneider Electric
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Compatibility Code : LC1D
    • Device Short Name : LC1D
    • Package Weight Lbs : 1.431 kg
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 53 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1102005EN
    • Pep Verification Date : 2025-11-20
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Climatic Withstand : IACS E10 exposure to damp heat, IACS E10 exposure to damp heat
    • EU ROHS Directive : Compliant​, Compliant
    • IP Degree Of Protection : IP2X IEC 60529, IP2X IEC 60529, IP2X VDE 0106, IP2X VDE 0106
    • Reach Regulation : Free of Substances of Very High Concern above the threshold, Reference contains Substances of Very High Concern above the threshold
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 53.35628831031477
    • Environmental Disclosure : ENVPEP1102005EN
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Pep Code : ENVPEP1102005EN
    • Pep Verification Date : 2025-11-20
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months