SQUARE D

Contactor, Tesys Deca, 3P(3NO),AC-3/AC-3e/<=440V 50A,208V AC 50/60Hz coil, screw clamp terminals

CONTACTOR 600VAC 50AMP IEC +OP

SQDLC1D50LE7 LC1D50LE7 3389110296143
446.98 / EA
http://schema.org/OutOfStock
  • Country of Origin: Czechia
  • Depth: 119 mm
  • Height: 127 mm
  • Net Weight: 1.4 kg
  • Warranty Length: 18 mth
  • Weight: 1.4 kg
  • Width: 75 mm
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CCC || CSA || BV || GL || UL || GOST || DNV || RINA || LROS (Lloyds register of shipping) || UKCA
    • Height : 127 mm
    • Standards : CSA C22.2 No 14 || UL 508 || IEC 60947-4-1 || IEC 60947-5-1 || EN 60947-5-1 || EN 60947-4-1
    • Climatic Withstand : IACS E10 exposure to damp heat
    • Net Weight : 1.4 kg
    • Flame Retardance : V1 conforming to UL 94
    • Ip Degree Of Protection : IP2X IEC 60529 || IP2X VDE 0106
    • Mechanical Robustness : shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Width : 75 mm
    • Depth : 119 mm
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110205EN
    • Packaging Without Single Use Plastic : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Circularity Profile : N/A
    • Take-Back : No
    • Pvc Free : Yes
    • Sustainable Packaging : Yes
    • Global Warming ; Total Life Cycle​ : 62 kg CO2 eq.
    • Eu Rohs Directive : Compliant
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 61.71667019
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
    • Minimum Switching Current : 5 mA for control circuit
    • Power Dissipation Per Pole : 3.7 W AC-3 || 9.6 W AC-1 || 3.7 W AC-3e
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Terminals Description Iso N°1 : (A1-A2)CO || (13-14)NO || (21-22)NC
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for control circuit || 80 A (at 60 °C) for power circuit
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz || 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz || 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz || 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
    • Mounting Support : rail || plate
    • Control Circuit Type : AC 50/60 Hz
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Insulation Resistance : > 10 MOhm for control circuit
    • Rated Breaking Capacity : 900 A at 440 V for power circuit conforming to IEC 60947
    • Irms Rated Making Capacity : 900 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for control circuit conforming to IEC 60947-5-1
    • Associated Fuse Rating : 10 A gG for control circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
    • Inrush Power In Va : 140-140 VA cos phi 0.75 (at 20 °C) || 160-160 VA cos phi 0.75 (at 20 °C)
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
    • Pole Contact Composition : 3 NO
    • Connections - Terminals : control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: rigid || power circuit: screw terminals 2 2.5-16 mm² - cable stiffness: rigid || power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end || power circuit: screw terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end || power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end || power circuit: screw terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Operating Time : 4...19 ms opening || 12...26 ms closing
    • Minimum Switching Voltage : 17 V for control circuit
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm || control circuit 1.7 N.m screw clamp terminal pozidriv No 2
    • Mechanical Durability : 6000000 cycles
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Compatibility Code : LC1D
    • Hold-In Power Consumption In Va : 13-13 VA 60 Hz cos phi 0.3 (at 20 °C) || 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Overvoltage Category : III
    • Maximum Horse Power Rating : 3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors || 15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 hp at 575/600 V AC 60 Hz for 3 phase motors
    • Motor Power Kw : 22 kW at 380...400 V AC 50 Hz || 25 kW at 415 V AC 50 Hz || 30 kW at 440 V AC 50 Hz || 30 kW at 500 V AC 50 Hz || 33 kW at 660...690 V AC 50 Hz || 15 kW at 220...230 V AC 50 Hz || 30 kW at 1000 V AC 50 Hz
    • [Ui] Rated Insulation Voltage : control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
    • Heat Dissipation : 4-5 W at 50/60 Hz for control circuit
    • Protective Cover : with
  • Specifications
    • Country of Origin : Czechia
    • Width : 75 mm
    • Height : 127 mm
    • Weight : 1.4 kg
    • [Uc] Control Circuit Voltage : 208 V AC 50/60 Hz
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • Range Of Product : TeSys Deca
    • Contactor Application : resistive load || motor control
    • Product Or Component Type : contactor
    • Range : TeSys
    • Utilisation Category : AC-3 || AC-2 || AC-1 || AC-4 || AC-3e
    • [Ie] Rated Operational Current : 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Poles Description : 3P
    • Device Short Name : LC1D