IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 120VAC 60Hz coil, open style

CONTACTOR 600VAC 40AMP IEC +OP

SQDLC1D40G6 LC1D40G6 3389110417005
411.10 / EA
http://schema.org/OutOfStock
  • Country of Origin: Czechia
  • Depth: 4.69 in
  • Height: 5 in
  • Warranty Length: 18 mth
  • Width: 2.95 in
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up
QTY
  • Product Description
  • Features
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up
  • Uc Control Circuit Voltage
    • 120 V AC 60 Hz
  • Insulation Resistance
    • > 10 MOhm for control circuit
  • Heat Dissipation
    • 4-5 W at 50/60 Hz for control circuit
  • Connections Terminals
    • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
    • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: so
  • Mounting Support
    • rail
    • plate
  • Uimp Rated Impulse Withstand Voltage
    • 6 kV IEC 60947
  • Climatic Withstand
    • IACS E10 exposure to damp heat
  • Power Dissipation Per Pole
    • 5.4 W AC-1
    • 2.4 W AC-3
    • 2.4 W AC-3e
  • Maximum Operating Rate
    • 3600 cyc/h at 60 °C
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0 kg CO2 eq.
    • 0.03709489667225843
  • Non Overlap Time
    • 1.5 ms on de-energisation between NC and NO contacts
    • 1.5 ms on energisation between NC and NO contacts
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 2.4684457274736755
    • 2 kg CO2 eq.
  • Standards
    • EN 60947-5-1
    • IEC 60947-4-1
    • UL 60947-4-1
    • CSA C22.2 No 14
    • EN 60947-4-1
    • IEC 60947-5-1
  • Ue Rated Operational Voltage
    • power circuit <= 690 V AC 25...400 Hz
  • Ui Rated Insulation Voltage
    • control circuit 600 V CSA
    • control circuit 600 V UL
    • power circuit 600 V CSA
    • power circuit 600 V UL
    • power
  • Operating Time
    • 12...26 ms closing
    • 4...19 ms opening
  • Control Circuit Type
    • AC 60 Hz
  • Ip Degree Of Protection
    • IP2X IEC 60529
    • IP2X VDE 0106
  • Minimum Switching Voltage
    • 17 V for control circuit
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 8 kg CO2 eq.
    • 8.200493000872394
  • Average Impedance
    • 1.5 mOhm - Ith 60 A 50 Hz for power circuit
  • Maximum Horse Power Rating
    • 10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA
    • 10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming t
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • System Integrator
  • Fire Resistance
    • 850 °C IEC 60695-2-1
  • Contactor Application
    • resistive load
    • motor control
  • Flame Retardance
    • V1 conforming to UL 94
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 54 kg CO2 eq.
    • 53.57766617965933
  • Persona Type Ids
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SI
  • Auxiliaries
    • LADN22
    • LADN11
    • LADN20
    • LAD8N11
    • LADT2
    • LADN40
    • LADN31
    • LADN02
    • LADT0
  • Safety Reliability Level
    • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
    • B10d = 1369863 cycles contactor with nominal load EN/ISO 13
  • Carbon Footprint Of The Distribution Phase A4
    • 1.7614752578811517
    • 2 kg CO2 eq.
  • Tightening Torque
    • control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm
    • control circuit 1.7 N.m sc
  • Ith Conventional Free Air Thermal Current
    • 10 A (at 60 °C) for control circuit
    • 60 A (at 60 °C) for power circuit
  • Irms Rated Making Capacity
    • 140 A AC for control circuit conforming to IEC 60947-5-1
    • 800 A at 440 V for power c
  • Mechanical Robustness
    • shocks contactor opened 10 Gn for 11 ms)
    • shocks contactor closed 15 Gn for 11 ms)
    • vibratio
  • Minimum Switching Current
    • 5 mA for control circuit
  • Operating Altitude
    • 9842.52 ft (3000 m) without derating
  • Motor Power Kw
    • 18.5 kW at 380...400 V AC 50/60 Hz
    • 22 kW at 500 V AC 50/60 Hz
    • 30 kW
  • Control Circuit Voltage Limits
    • 0.85...1.1 Uc (60-60 °C):operational AC 60 Hz
    • 0.3...0.6 Uc (60-60 °C):
  • Utilisation Category
    • AC-2
    • AC-1
    • AC-3
    • AC-4
    • AC-3e
  • Ie Rated Operational Current
    • 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • 60 A (at <60 °C) at <= 440 V AC AC
  • Hold In Power Consumption In Va
    • 13-13 VA 50 Hz cos phi 0.3 (at 20 °C)
    • 15-15 VA 60 Hz cos phi 0.3 (at 20 °C)
    • 15-15 VA 60 Hz cos phi 0.3
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Inrush Power In Va
    • 140-140 VA cos phi 0.75 (at 20 °C)
    • 160-160 VA cos phi 0.75 (at 20 °C)
  • Associated Fuse Rating
    • 10 A gG for control circuit conforming to IEC 60947-5-1
    • 80 A gG at <= 690 V coordinati
  • Permissible Ambient Air Temperature Around The Device
    • -5-60 °C
    • -40-70 °C at Uc
  • Rated Breaking Capacity
    • 800 A at 440 V for power circuit conforming to IEC 60947
  • Product Certifications
    • GL
    • BV
    • DNV
    • LROS (Lloyds register of shipping)
    • RINA
    • UL
    • CCC
    • CSA
    • GOST
    • UKCA
    • CB
  • Important Information Attributes
    • Country Id : US
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • ETIM 10 : EC000066
    • Html Descr : CONTACTOR 600VAC, 120 V AC 60 Hz, 3P, 3 NO, AC-3, 1 NO + 1 NC, 40AMP IEC +OPTIONS
    • Manufacturer : Schneider Electric
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Manufacturing Carbon Footprint : 8.20049300087239
    • Distribution Carbon Footprint : 1.76147525788115
    • Installation Carbon Footprint : 3.70948966722584e-02
    • Use Carbon Footprint : 53.5776661796593
    • End Of Life Carbon Footprint : 2.46844572747368
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS Eur In Scope : Yes
    • ROHS Eur Status : Compliant
    • ROHS Eur Conformity Date : 1926
    • ROHS Eur Full Compliance Status : Compliant
    • ROHS Eur Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • China ROHS Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Compatibility Code : LC1D
    • Device Short Name : LC1D
    • Mechanical Durability : 6000000 cycles
    • Overvoltage Category : III
    • Package Weight Lbs : 1.449 kg
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : No
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 66 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 66.04517506255881
    • Relationshiptype : Compatible relationship
    • Add Ons : LAD4RCU
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS Url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=617346&lang=en-us
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 66.0451750625588
    • Environmental Disclosure : ENVPEP110205EN
    • Eu Rohs Directive : Compliant
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Czechia
    • Height : 5 in
    • Width : 2.95 in
    • Depth : 4.69 in