Roof Connected Cooling Unit, Climasys CU, 1,2kW, 2 Poles, 400/460V, 50/60Hz, IP54

Roof Connected Cooling Unit, Climasys CU, 1,2kW, 2 Poles, 400/460V, 50/60Hz, IP54

SQDNSYCU1K22P4RDG NSYCU1K22P4RDG 3606486055410
4938.71 / EA
http://schema.org/OutOfStock
  • Depth: 395 mm
  • Height: 16.22 in
  • Material: Steel
  • Width: 23 3/7 in
QTY
  • Specifications
  • Physical Attributes
    • Color : Gray RAL 7035)
  • Complementary Attributes
    • Line Rated Current : 1.9 A
    • Rated Power In W : 1280 W
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB, SI
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Cooling Power : 1280 W 50/60 Hz L35-L35, 810 W 50/60 Hz L35-L50
    • Power Consumption In W : 699 W 50/60 Hz, L35-L35, 793 W 50/60 Hz, L35-L50
    • Certificate Agency : UL, IEC, EN
    • [Us] Rated Supply Voltage : 380...415 V 2 phases 50 Hz EN/IEC, 400/460 V +/- 6 % 2 phases 60 Hz UL
    • Carbon Footprint Of The Distribution Phase [A4] : 3.9654679068566083, 4 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 80 kg CO2 eq., 80.23164692170015
    • Carbon Footprint Of The Installation Phase [A5] : 6.024228884450607, 6 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 157 kg CO2 eq., 156.57967383474312
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 3 090 kg CO2 eq., 3089.7546392370355
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Pre Comm Announcement Date : 2023-06-16
    • Pre Comm Date : 2023-06-16
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2301019EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 2327
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Control Type : electronic controller
    • Cooling Gas Type : R513a 0.183 kg)
    • Energy Efficiency Ratio : 1.8
    • Incomer Device : M9F23216
    • Inrush Current : 8 A
    • Material : steel
    • Mounting Location : roof of enclosure
    • Mounting Mode : by screws
    • Noise Level : 74 dB
    • Pressure : 32 bar
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Destination : for enclosure
    • Product Name : CU
    • Product Or Component Type : cooling unit
    • Protection Type : 2 phases 15 A (T)
    • Range : ClimaSys
    • Returnability : No
    • Software Version : v6.2.5-6
    • Sustainable Packaging : No
    • Temperature Setting Range : 20-50 °C 50/60 Hz
    • Total Lifecycle Carbon Footprint : 3 337 kg CO2 eq.
    • Type Of Ventilation Filter : optional external circuit filter
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP2301019EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-12-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0013-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : To produce 2 kW of cooling, according to the appropriate usage scenario defined in the EN 14825 standard and during the 22-year reference lifetime of the product.& 10& 10- Product dimensions 1000mm x 405mm x 225mm& 10- IP55 conforming to IEC 60529 (on the internal circuit)& 10- IP24 conforming to IEC 60529 (on the external circuit)& 10- Technology: Air/Air& 10- Non-reversible& 10- Cooling capacity - 2kW& 10- SEER - 1.9806& 10- Refrigerant used - R513a& 10- Refill threshold - Cannot Refill& 10- Where Used - Industrial
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 22
    • Energy Consumption On Product Lifetime, In Kwh : 7542.113
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; Malta, MT
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Recyclability Potential, In % : 89
    • Height Nominal : 412 mm
    • Height Useful : 412 mm
    • Width Nominal : 595 mm
    • Width Real : 595 mm
    • F-gas Free : Product containing F-gas
    • F-gas Usage Performance : Product containing F-gas
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 41.500 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Other Technical Guide : CPTG001_EN
    • Customs Code : 8415103040
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Air Flow : internal circuit 850 m3/h 50/60 Hz, external circuit 850 m3/h 50/60 Hz
    • Ambient Air Temperature For Operation : inside the enclosure 20-50 °C 50/60 Hz, outside the enclosure 5-55 °C 50/60 Hz
    • Directives : 2006/42/EC - machinery, 2014/30/EU - electromagnetic compatibility, 2011/65/EU - RoHS
    • Ip Degree Of Protection : IP54 IEC 60529 on the internal circuit), IP24 IEC 60529 on the external circuit)
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Carbon Footprint : 3336.555656784786
    • Circularity Profile : ENVEOLI2301019EN
    • Environmental Disclosure : ENVPEP2301019EN
    • Eu Rohs Directive : Compliant
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2301019EN
    • Pep Verification Date : 2025-12-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0013-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : cooling unit
  • ETIM
    • ETIM 8 : EC000855
    • ETIM 9 : EC000855
  • Surge Protection And Filtering Attributes
    • Type Of Ventilation Filter : optional external circuit filter
  • Specifications
    • Country of Origin : Malta
    • Height : 16.22 in
    • Width : 23.43 in
    • Depth : 395 mm