SQUARE D

Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 24VDC, without control terminals

12A SELF-PR.REV.STR W/TERMS-LU

SQDLU2BA0BL LU2BA0BL 3389110363098
477.11 / EA
http://schema.org/OutOfStock
  • Depth: 126 mm
TeSys U standard reversing power base, 3 poles (3NO), rated 12A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 5.5kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0BL to be supplied with 24V DC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys U standard reversing power base, 3 poles (3NO), rated 12A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 5.5kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0BL to be supplied with 24V DC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Control Circuit Voltage Limits : 14.5 V DC drop-out20...27 V DC in operation
    • Maximum Operating Rate : 3600 cyc/h
  • Important Information Attributes
    • Device Application : motor control, motor protection
    • Fire Resistance : 960 °C parts supporting live components IEC 60695-2-12, 650 °C IEC 60695-2-12
    • Resistance To Fast Transients : 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
    • Safe Separation Of Circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
    • Tightening Torque : power circuit: 1.9-2.5 N.m flat screwdriver 6 mm, power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6 mm, power circuit: 1.9-2.5 N.m pozidriv No 2 screwdriver 6 mm
    • Typical Current Consumption : 120 mA 24 V DC I maximum while closing, 120 mA 24 V DC I rms sealed
    • Utilisation Category : AC-43, AC-44, AC-41
    • Certificate Agency : CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
    • [Ics] Rated Service Breaking Capacity : 50 kA 230 V, 50 kA 440 V10 kA 500 V4 kA 690 V
    • [Ie] Rated Operational Current : 12 A <= 440 V, 12 A 500 V9 A 690 V
    • [Ui] Rated Insulation Voltage : 690 V IEC 60947-6-2 3)600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
    • Connections - Terminals : power circuit: screw clamp terminals 2 cable(s) 1-6 mm² rigidpower circuit: screw clamp terminals 1 cable(s) 1-10 mm² rigidpower circuit: screw clamp terminals 1 cable(s) 1-6 mm² flexible with cable endpower circuit: screw clamp terminals 1 cable(s) 2.5-10 mm² flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 1-6 mm² flexible with cable end, power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable endcontrol circuit: without connection
    • Carbon Footprint Of The Distribution Phase [A4] : 0.6843699101945505, 0.7 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 3.2391501435711954, 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0.1 kg CO2 eq., 0.0893852969884094
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 9 kg CO2 eq., 8.698303583482293
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 10 kg CO2 eq., 10.242554388924361
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-06-27
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2407003EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2023
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Compatibility Code : LU2B
    • Device Short Name : LU2B
    • Energy Efficiency Optimized : False
    • Fixing Mode : clipped (DIN rail)screw-fixed (plate)
    • Heat Dissipation : 2-2 W control circuit with LUCA, LUCB, LUCC, LUCD1.7-1.7 W control circuit with LUCM
    • Immunity To Microbreaks : 3 ms control circuit
    • Immunity To Radioelectric Fields : 10 V IEC 61000-4-6
    • Immunity To Voltage Dips : 70 % / 500 ms IEC 61000-4-11
    • Inrush Restraint Duration : 15 ms DC
    • Mechanical Durability : 15 Mcycles
    • Network Frequency : 40...60 Hz
    • Number Of Poles : 3P
    • Operating Time : 150 ms with change of direction power circuit75 ms without change of direction power circuit35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit75 ms closing with LUCM control circuit70 ms closing with LUCA, LUCB, LUCC, LUCD control circuit
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys Ultra
    • Product Or Component Type : reversing power base
    • Protective Treatment : TH IEC 60068
    • Range : TeSys
    • Range Of Product : TeSys Ultra
    • Resistance To Electrostatic Discharge : 8 kV 3 in open air IEC 61000-4-28 kV 4 on contact IEC 61000-4-2
    • Resistance To Radiated Fields : 10 V/m 3 IEC 61000-4-3
    • Returnability : No
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Shock Resistance : 10 gn power poles open IEC 60068-2-2715 gn power poles closed IEC 60068-2-27
    • Software Version : v6.1
    • Suitability For Isolation : yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 23 kg CO2 eq.
    • Vibration Resistance : 2 gn 5-300 Hz) power poles open IEC 60068-2-274 gn 5-300 Hz) power poles closed IEC 60068-2-27
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP2407003EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 153.3
    • Energy Model - Manufacturing [A1-a3] : France, FR
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2018; France, FR
    • Recyclability Potential, In % : 58
    • Height Nominal : 224 mm
    • Width Nominal : 45 mm
    • [Ith] Conventional Free Air Thermal Current : 12 A
    • [Uc] Control Circuit Voltage : 24 V DC
    • [Ue] Rated Operational Voltage : 690 V AC power circuit
    • [Uimp] Rated Impulse Withstand Voltage : 6 kVIEC 60947-6-2
    • Halogen-free Status : Product contains halogen above thresholds
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 1.281 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536490065
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -25-60 °C with LUCM, -25-60 °C with LUCM, -25-70 °C with LUCA, LUCB, LUCC, LUCD, -25-70 °C with LUCA, LUCB, LUCC, LUCD-25-60 °C with LUCM, -25-60 °C with LUCM, -25-70 °C with LUCA, LUCB, LUCC, LUCD
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Ip Degree Of Protection : IP20 IEC 60947-1 front panel and wired terminals), IP20 IEC 60947-1 other faces)IP40 IEC 60947-1 front panel outside connection zone)
    • Product Compatibility : control unit LUC.X6BL, control unit LUC.1XBL, control unit LUC.05BL, control unit LUC.12BL
    • Take Back : No
    • Halogene Performance : Product contains halogen above thresholds
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 22.953763323160807
    • Circularity Profile : ENVEOLI2407003EN
    • Environmental Disclosure : ENVPEP2407003EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Product contains halogen above thresholds
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2407003EN
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : reversing power base
    • Range Of Product : TeSys Ultra
  • ETIM
    • ETIM 8 : EC001037
    • ETIM 9 : EC001037
  • Specifications
    • Country of Origin : Brazil, France
    • Depth : 126 mm