reversing contactor TeSys Deca - 3 poles - AC-3 - 440V 40A - coil 120V AC 60 Hz - TQPKG

TESYS D 3P EVERLINK AC REV CON

SQDLC2D40AG7TQ LC2D40AG7TQ 3606480787522
766.89 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 120 mm
  • Height: 122 mm
  • Net Weight: 1.87 kg
  • Weight: 1.87 kg
  • Width: 119 mm
TeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 40A/590V AC-3 (18.5kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), power connection by EverLink BTR screw connectors, control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (119mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 40A/590V AC-3 (18.5kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), power connection by EverLink BTR screw connectors, control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (119mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Specifications
    • Country of Origin : France
    • Width : 119 mm
    • Height : 122 mm
    • Weight : 1.87 kg
    • Interlocking Type : mechanical
    • [Uc] Control Circuit Voltage : 120 V AC 60 Hz
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
    • Power Dissipation Per Pole : 5.4 W AC-1 || 3.4 W AC-3
    • Average Impedance : 1.5 mOhm - Ith 60 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit || 60 A (at 60 °C) for power circuit
    • Mounting Support : plate || rail
    • Control Circuit Type : AC 60 Hz
    • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Contactor Application : resistive load || motor control
    • Rated Breaking Capacity : 800 A at 220/415/440 V for power circuit conforming to IEC 60947
    • Product Or Component Type : reversing contactor
    • Product Certifications : CCC || CSA || DNV || EAC || UKCA
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947-4
    • Product Name : TeSys Deca
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Connections - Terminals : control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit screw clamp terminals 1 1-35 mm²flexible without cable end || power circuit screw clamp terminals 2 1-25 mm²flexible without cable end || power circuit screw clamp terminals 1 1-35 mm²flexible with cable end || power circuit screw clamp terminals 2 1-25 mm²flexible with cable end || power circuit screw clamp terminals 1 1-35 mm²solid without cable end || power circuit screw clamp terminals 2 1-25 mm²solid without cable end
    • Range : TeSys || TeSys Deca
    • Pole Contact Composition : 3 NO
    • Device Presentation : preassembled with reversing power busbar
    • Utilisation Category : AC-1 || AC-3
    • [Ie] Rated Operational Current : 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • Operating Time : 4...19 ms opening || 12...26 ms closing
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Electrical Durability : 1.5 Mcycles 40 A AC-3 <= 440 V || 1.4 Mcycles 60 A AC-1 <= 440 V
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm
    • Poles Description : 3P
    • Overvoltage Category : III
    • Motor Power Kw : 18.5 kW at 380...400 V AC 50 Hz || 11 kW at 220...230 V AC 50 Hz || 22 kW at 415...440 V AC 50 Hz || 22 kW at 500 V AC 50 Hz || 30 kW at 660...690 V AC 50 Hz
    • Maximum Horse Power Rating : 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 3 hp at 115 V AC 60 Hz for 1 phase motors || 30 hp at 575...600 V AC 60 Hz for 3 phase motors || 30 hp at 460...480 V AC 60 Hz for 3 phase motors || 5 hp at 230...240 V AC 60 Hz for 1 phase motors || 10 hp at 230...240 V AC 60 Hz for 3 phase motors
    • [Ui] Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
    • Mechanical Durability : 6000000 cycles
    • Device Short Name : LC2D
    • [Icw] Rated Short-Time Withstand Current : 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit || 320 A 40 °C - 10 s for power circuit || 720 A 40 °C - 1 s for power circuit || 72 A 40 °C - 10 min for power circuit || 165 A 40 °C - 1 min for power circuit
    • Protective Cover : with
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1503009EN
    • Packaging Without Single Use Plastic : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Circularity Profile : ENVEOLI1503009EN
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 107.15533235931866
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 11.071525141639038
    • Carbon Footprint Of The Distribution Phase [A4] : 2 kg CO2 eq.
    • Pvc Free : Yes
    • Carbon Footprint Of The Installation Phase [A5] : 0.1 kg CO2 eq.
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 124 kg CO2 eq.
    • Eu Rohs Directive : Compliant
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 3.3326604790210625
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 123.98777621799216
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Current : 5 mA for signalling circuit
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-70 °C):drop-out AC 60 Hz || 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz || 1...1.1 Uc (60-70 °C):operational AC 60 Hz
    • Insulation Resistance : > 10 MOhm for signalling circuit
    • Inrush Power In Va : 160-160 VA 60 Hz 0.75 20 °C)
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Signalling Circuit Frequency : 25...400 Hz
    • Heat Dissipation : 4-5 W 60 Hz
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Hold-In Power Consumption In Va : 13-13 VA 20 °C) 0.3 60 Hz
  • Environment
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed10 Gn for 11 ms || shocks contactor open15 Gn for 11 ms
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Height : 122 mm
    • Climatic Withstand : IACS E10 || IEC 60947-1 Annex Q category D
    • Pollution Degree : 3
    • Net Weight : 1.87 kg
    • Flame Retardance : V1 conforming to UL 94
    • Ambient Air Temperature For Storage : -60-80 °C
    • Protective Treatment : TH IEC 60068-2-30
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Fire Resistance : 960 °C IEC 60695-2-1
    • Width : 119 mm